Literature DB >> 23238525

External radioactive markers for PET data-driven respiratory gating in positron emission tomography.

Florian Büther1, Iris Ernst, James Hamill, Hans T Eich, Otmar Schober, Michael Schäfers, Klaus P Schäfers.   

Abstract

PURPOSE: Respiratory gating is an established approach to overcoming respiration-induced image artefacts in PET. Of special interest in this respect are raw PET data-driven gating methods which do not require additional hardware to acquire respiratory signals during the scan. However, these methods rely heavily on the quality of the acquired PET data (statistical properties, data contrast, etc.). We therefore combined external radioactive markers with data-driven respiratory gating in PET/CT. The feasibility and accuracy of this approach was studied for [(18)F]FDG PET/CT imaging in patients with malignant liver and lung lesions.
METHODS: PET data from 30 patients with abdominal or thoracic [(18)F]FDG-positive lesions (primary tumours or metastases) were included in this prospective study. The patients underwent a 10-min list-mode PET scan with a single bed position following a standard clinical whole-body [(18)F]FDG PET/CT scan. During this scan, one to three radioactive point sources (either (22)Na or (18)F, 50-100 kBq) in a dedicated holder were attached the patient's abdomen. The list mode data acquired were retrospectively analysed for respiratory signals using established data-driven gating approaches and additionally by tracking the motion of the point sources in sinogram space. Gated reconstructions were examined qualitatively, in terms of the amount of respiratory displacement and in respect of changes in local image intensity in the gated images.
RESULTS: The presence of the external markers did not affect whole-body PET/CT image quality. Tracking of the markers led to characteristic respiratory curves in all patients. Applying these curves for gated reconstructions resulted in images in which motion was well resolved. Quantitatively, the performance of the external marker-based approach was similar to that of the best intrinsic data-driven methods. Overall, the gain in measured tumour uptake from the nongated to the gated images indicating successful removal of respiratory motion was correlated with the magnitude of the respiratory displacement of the respective tumour lesion, but not with lesion size.
CONCLUSION: Respiratory information can be assessed from list-mode PET/CT through PET data-derived tracking of external radioactive markers. This information can be successfully applied to respiratory gating to reduce motion-related image blurring. In contrast to other previously described PET data-driven approaches, the external marker approach is independent of tumour uptake and thereby applicable even in patients with poor uptake and small tumours.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23238525     DOI: 10.1007/s00259-012-2313-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  19 in total

1.  Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET.

Authors:  Sadek A Nehmeh; Yusuf E Erdi; Kenneth E Rosenzweig; Heiko Schoder; Steve M Larson; Olivia D Squire; John L Humm
Journal:  J Nucl Med       Date:  2003-10       Impact factor: 10.057

2.  Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT.

Authors:  R Glenn Wells; Terrence D Ruddy; Rob A DeKemp; Jean N DaSilva; Rob S Beanlands
Journal:  J Nucl Med       Date:  2010-07-21       Impact factor: 10.057

3.  Organ movement reduction in PET/CT using dual-gated list-mode acquisition.

Authors:  Norbert Lang; Mohammad Dawood; Florian Büther; Otmar Schober; Michael Schäfers; Klaus Schäfers
Journal:  Z Med Phys       Date:  2006       Impact factor: 4.820

4.  Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours.

Authors:  Wouter van Elmpt; James Hamill; Judson Jones; Dirk De Ruysscher; Philippe Lambin; Michel Ollers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-11       Impact factor: 9.236

5.  Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation.

Authors:  S Tong; A M Alessio; P E Kinahan
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

6.  Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography.

Authors:  Florian Büther; Iris Ernst; Mohammad Dawood; Peter Kraxner; Michael Schäfers; Otmar Schober; Klaus P Schäfers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-07-06       Impact factor: 9.236

7.  Physical performance of the new hybrid PET∕CT Discovery-690.

Authors:  V Bettinardi; L Presotto; E Rapisarda; M Picchio; L Gianolli; M C Gilardi
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

8.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes.

Authors:  Mohammad Dawood; Florian Büther; Norbert Lang; Otmar Schober; Klaus P Schäfers
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

9.  The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging.

Authors:  Chi Liu; Larry A Pierce; Adam M Alessio; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2009-11-20       Impact factor: 3.609

10.  Retrospective data-driven respiratory gating for PET/CT.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Paul K Marsden
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

View more
  8 in total

1.  Adaptation of the modified Bouc-Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: testing using MRI.

Authors:  Paul K R Dasari; Mohammed Salman Shazeeb; Arda Könik; Clifford Lindsay; Joyeeta M Mukherjee; Karen L Johnson; Michael A King
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

2.  False-positive stress PET-CT imaging in a patient with interstitial injection.

Authors:  Luciana Erthal; Fernanda Erthal; Rob S B Beanlands; Terrence D Ruddy; Robert A deKemp; Girish Dwivedi
Journal:  J Nucl Cardiol       Date:  2016-08-12       Impact factor: 5.952

3.  Assessing and accounting for the impact of respiratory motion on FDG uptake and viable volume for liver lesions in free-breathing PET using respiration-suspended PET images as reference.

Authors:  Guang Li; C Ross Schmidtlein; Irene A Burger; Carole A Ridge; Stephen B Solomon; John L Humm
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

4.  The impact of data-driven respiratory gating in clinical F-18 FDG PET/CT: comparison of free breathing and deep-expiration breath-hold CT protocol.

Authors:  Seo Young Kang; Byung Seok Moon; Hye Ok Kim; Hai-Jeon Yoon; Bom Sahn Kim
Journal:  Ann Nucl Med       Date:  2021-01-15       Impact factor: 2.668

5.  Quantitative and qualitative assessment of Yttrium-90 PET/CT imaging.

Authors:  Ali Asgar Attarwala; Flavia Molina-Duran; Karen-Anett Büsing; Stefan O Schönberg; Dale L Bailey; Kathy Willowson; Gerhard Glatting
Journal:  PLoS One       Date:  2014-11-04       Impact factor: 3.240

6.  A data-driven respiratory motion estimation approach for PET based on time-of-flight weighted positron emission particle tracking.

Authors:  Tasmia Rahman Tumpa; Shelley N Acuff; Jens Gregor; Sanghyeb Lee; Dongming Hu; Dustin R Osborne
Journal:  Med Phys       Date:  2020-12-13       Impact factor: 4.071

7.  On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework.

Authors:  Adam L Kesner; Paul J Schleyer; Florian Büther; Martin A Walter; Klaus P Schäfers; Phillip J Koo
Journal:  EJNMMI Phys       Date:  2014-06-17

8.  Evaluation of principal component analysis-based data-driven respiratory gating for positron emission tomography.

Authors:  Matthew D Walker; Kevin M Bradley; Daniel R McGowan
Journal:  Br J Radiol       Date:  2018-03-15       Impact factor: 3.039

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.