The Moxus Modular metabolic system evaluated with two sensors for ventilation against the Douglas bag method.

Hans Rosdahl1, Thomas Lindberg, Fredrik Edin, Johnny Nilsson.   

Abstract

This study evaluated the Moxus metabolic system with the Douglas bag method (DBM) as criterion. Reliability and validity were investigated in a wide range of ventilation and oxygen uptake and two sensors for determining ventilation were included. Thirteen well-trained athletes participated in one pre-test and four tests for data collection, exercising on a cycle ergometer at five submaximal powers (50-263 W) and at VO₂max. Gas exchange variables were measured simultaneously using a serial setup with data collected on different days in an order randomized between Moxus with pneumotachometer (MP) and turbine flowmeter (MT) sensors for ventilation. Reliability with both sensors was comparable to the DBM. Average CV (%) of all exercise intensities were with MP: 3.0 ± 1.3 for VO₂, 3.8 ± 1.5 for VCO₂, 3.1 ± 1.2 for the respiratory exchange ratio (RER) and 4.2 ± 0.8 for V E. The corresponding values with MT were: 2.7 ± 0.3 for VO₂, 4.7 ± 0.4 for VCO₂, 3.3 ± 0.9 for RER and 4.8 ± 1.4 for V E. Validity was acceptable except for small differences related to the determination of ventilation. The relative differences in relation to DBM at the powers including VO₂max were similar for both sensors with the ranges being: +4 to -2 % for V E, +5 to -3 % for VO₂ and +5 to -4 % for VCO₂ while RER did not differ at any power. The Moxus metabolic system shows high and adequate reliability and reasonable validity over a wide measurement range. At a few exercise levels, V E differed slightly from DBM, resulting in concomitant changes in VO₂ and VCO₂.

Entities:  

Mesh:

Year:  2012        PMID: 23224357     DOI: 10.1007/s00421-012-2551-1

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  30 in total

1.  Oxygen uptake during the first minutes of heavy muscular exercise.

Authors:  P O ASTRAND; B SALTIN
Journal:  J Appl Physiol       Date:  1961-11       Impact factor: 3.531

Review 2.  Performance characteristics of gas analysis systems: what we know and what we need to know.

Authors:  G Atkinson; R C R Davison; A M Nevill
Journal:  Int J Sports Med       Date:  2005-02       Impact factor: 3.118

Review 3.  Validity and reliability of selected commercially available metabolic analyzer systems.

Authors:  L D Hodges; D A Brodie; P D Bromley
Journal:  Scand J Med Sci Sports       Date:  2005-10       Impact factor: 4.221

Review 4.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

5.  Maximal oxygen uptake in athletes.

Authors:  B Saltin; P O Astrand
Journal:  J Appl Physiol       Date:  1967-09       Impact factor: 3.531

6.  Reliability of cycling gross efficiency using the Douglas bag method.

Authors:  James G Hopker; Simon A Jobson; Hannah C Gregson; Damian Coleman; Louis Passfield
Journal:  Med Sci Sports Exerc       Date:  2012-02       Impact factor: 5.411

7.  Six sessions of sprint interval training increases muscle oxidative potential and cycle endurance capacity in humans.

Authors:  Kirsten A Burgomaster; Scott C Hughes; George J F Heigenhauser; Suzanne N Bradwell; Martin J Gibala
Journal:  J Appl Physiol (1985)       Date:  2005-02-10

8.  Computerized determination of pneumotachometer characteristics using a calibrated syringe.

Authors:  M P Yeh; R M Gardner; T D Adams; F G Yanowitz
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-07

9.  Myostatin is a skeletal muscle target of growth hormone anabolic action.

Authors:  Wei Liu; Scott G Thomas; Sylvia L Asa; Nestor Gonzalez-Cadavid; Shalendar Bhasin; Shereen Ezzat
Journal:  J Clin Endocrinol Metab       Date:  2003-11       Impact factor: 5.958

10.  A metabolic cart for measurement of oxygen uptake during human exercise using inspiratory flow rate.

Authors:  Kurt Jensen; Susanne Jørgensen; Lars Johansen
Journal:  Eur J Appl Physiol       Date:  2002-04-26       Impact factor: 3.078

View more
  5 in total

1.  The validity of the Moxus Modular metabolic system during incremental exercise tests: impacts on detection of small changes in oxygen consumption.

Authors:  Fernando G Beltrami; Christian Froyd; Asgeir Mamen; Timothy D Noakes
Journal:  Eur J Appl Physiol       Date:  2014-01-30       Impact factor: 3.078

2.  Validity of sports watches when estimating energy expenditure during running.

Authors:  Lilian Roos; Wolfgang Taube; Nadja Beeler; Thomas Wyss
Journal:  BMC Sports Sci Med Rehabil       Date:  2017-12-20

3.  Metabolic Equivalent in Adolescents, Active Adults and Pregnant Women.

Authors:  Katarina Melzer; Juliane Heydenreich; Yves Schutz; Anne Renaud; Bengt Kayser; Urs Mäder
Journal:  Nutrients       Date:  2016-07-20       Impact factor: 5.717

4.  Reliability and Validation of the Hexoskin Wearable Bio-Collection Device During Walking Conditions.

Authors:  Jeffrey Montes; John C Young; Richard Tandy; James W Navalta
Journal:  Int J Exerc Sci       Date:  2018-10-01

5.  Inter- and intra-unit reliability of the COSMED K5: Implications for multicentric and longitudinal testing.

Authors:  Kay Winkert; Rupert Kamnig; Johannes Kirsten; Jürgen M Steinacker; Gunnar Treff
Journal:  PLoS One       Date:  2020-10-23       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.