Literature DB >> 23223972

Modular sleeves with ceramic heads in isolated acetabular cup revision in younger patients-laboratory and experimental analysis of suitability and clinical outcomes.

Peter Helwig1, Lukas Konstantinidis, Anja Hirschmüller, Anke Bernstein, Oliver Hauschild, Norbert P Südkamp, Björn G Ochs.   

Abstract

PURPOSE: One possibility in hip arthroplasty revisions is to combine a modular ceramic head with an adapter or sleeve in isolated acetabular cup replacement. This study consisted of an experimental part to analyse the reliability of taper damage predictions, and a clinical part to analyse the outcomes of modular ceramic head implantation in a case series of isolated cup replacements.
METHODS: Analysis of scratch size on 11 explanted hip stems were examined macroscopically and by stereomicroscopy to classify damage to the conical taper. The second part consisted of a prospective analysis of isolated cup revisions using a modular ceramic head, performed in two orthopedic centres.
RESULTS: Analysis of scratch size on the taper yielded inter-observer correlations of 0.545-0.909; comparison with stereomicroscopic data recordings yielded a moderate correlation, with values between 0.545 and 0.090. The clinical study included 47 isolated acetabular cup revisions involving modular ceramic heads. Ceramic head failure did not occur during the average clinical and radiological observation period of 26 months. Mean Harris Hip Score (HHS) at follow-up was 70 points.
CONCLUSION: From these results, it can be concluded that damage to the implanted stem taper cannot be reliably predicted intraoperatively. Nevertheless, the clinical outcomes did show that there were no problems with the ceramic heads over the short observation period. The application of modular ceramic heads in younger patients requiring isolated cup replacement requires proper risk-benefit analysis, but is possible and appears to be a safe procedure.

Entities:  

Mesh:

Year:  2012        PMID: 23223972      PMCID: PMC3532640          DOI: 10.1007/s00264-012-1735-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  20 in total

1.  Should the well-fixed, uncemented femoral components be revised during isolated acetabular revision?

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Kenji Kitamura; Tadami Matsumoto
Journal:  Arch Orthop Trauma Surg       Date:  2010-07-28       Impact factor: 3.067

2.  Isolated acetabular revision hip arthroplasty with the use of uncemented cup.

Authors:  Yee-Suk Kim; Young-Ho Kim; Kyu-Tae Hwang; Il-Yong Choi
Journal:  J Arthroplasty       Date:  2009-07-29       Impact factor: 4.757

3.  An analysis of stably fixed femoral components retained during revision total hip arthroplasty.

Authors:  Hyung Joon Cho; Seung Beom Han; Jong Hoon Park; Sang Won Park
Journal:  J Arthroplasty       Date:  2011-03-23       Impact factor: 4.757

4.  Metal Ion release with large-diameter metal-on-metal hip arthroplasty.

Authors:  Pascal-André Vendittoli; Traian Amzica; Alain G Roy; Daniel Lusignan; Julien Girard; Martin Lavigne
Journal:  J Arthroplasty       Date:  2010-03-04       Impact factor: 4.757

5.  Alternative bearing surface options for revision total hip arthroplasty.

Authors:  Deepan Patel; Javad Parvizi; Peter F Sharkey
Journal:  Instr Course Lect       Date:  2011

6.  Is there a risk in placing a ceramic head on a previously implanted trunion?

Authors:  Didier Hannouche; Jérôme Delambre; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

7.  Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years.

Authors:  Stefan Lakemeier; Guenter Aurand; Nina Timmesfeld; Thomas J Heyse; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-27       Impact factor: 2.362

8.  Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces.

Authors:  Kevin J Bozic; Kevin Ong; Edmund Lau; Steven M Kurtz; Thomas P Vail; Harry E Rubash; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

9.  The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Authors:  Donald S Garbuz; Michael Tanzer; Nelson V Greidanus; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2009-08-21       Impact factor: 4.176

Review 10.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29
View more
  5 in total

Review 1.  [Partial exchange in total hip arthroplasty : What can we combine?]

Authors:  P Weber; A Steinbrück; A C Paulus; M Woiczinski; F Schmidutz; A Fottner; V Jansson
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

2.  Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.

Authors:  Seung-Jae Lim; Seung-Pil Jang; Dong-Wook Kim; Young-Wan Moon; Youn-Soo Park
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

Review 3.  [Partial or full component exchange in hip revision? : The relevance of off-label use and mix & match].

Authors:  K P Günther; K Tucker; P Kjaersgaard-Andersen; J Lützner; J P Kretzer; R Nelissen; T Lange; L Zagra
Journal:  Orthopadie (Heidelb)       Date:  2022-06-27

4.  Cementless dual-mobility cup in total hip arthroplasty revision.

Authors:  Jean Louis Prudhon; François Steffann; André Ferreira; Régis Verdier; Thierry Aslanian; Jacques Caton
Journal:  Int Orthop       Date:  2014-07-31       Impact factor: 3.075

Review 5.  EFORT recommendations for off-label use, mix & match and mismatch in hip and knee arthroplasty.

Authors:  Keith Tucker; Klaus-Peter Günther; Per Kjaersgaard-Andersen; Jörg Lützner; Jan Philippe Kretzer; Rob G H H Nelissen; Toni Lange; Luigi Zagra
Journal:  EFORT Open Rev       Date:  2021-11-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.