Literature DB >> 20206466

Metal Ion release with large-diameter metal-on-metal hip arthroplasty.

Pascal-André Vendittoli1, Traian Amzica, Alain G Roy, Daniel Lusignan, Julien Girard, Martin Lavigne.   

Abstract

Preoperative and postoperative ion concentrations were measured in 29 metal-on-metal, large-diameter head total hip arthroplasty (LDH-THA) patients. Mean chromium, cobalt (Co), and titanium levels from LDH-THA were 1.3, 2.2, and 2.7 μg/L at 12 months. The open femoral head design showed significantly higher Co concentrations than the closed design (3.0 vs 1.8 μg/L, P = .037). Compared with previously published ion levels from a hip resurfacing system presenting the same bearing characteristics, Co levels were significantly higher in LDH-THA (2.2 vs 0.7 μg/L, P < .001). This study has demonstrated that the addition of a sleeve with modular junctions and an open femoral head design of LDH-THA causes more Co release than bearing surface wear (157% and 67%, respectively). Even if no pathologic metal ion threshold level has been determined, efforts should be made to minimize its release. We recommend modification or abandonment of the modular junction and femoral head open design for this specific LDH-THA system.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20206466     DOI: 10.1016/j.arth.2009.12.013

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  25 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Metallic ion release after knee prosthesis implantation: a prospective study.

Authors:  Adrien Lons; Sophie Putman; Gilles Pasquier; Henri Migaud; Elodie Drumez; Julien Girard
Journal:  Int Orthop       Date:  2017-06-14       Impact factor: 3.075

3.  The withdrawn ASR™ THA and hip resurfacing systems: how have our patients fared over 1 to 6 years?

Authors:  Kevin T Hug; Tyler S Watters; Thomas P Vail; Michael P Bolognesi
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

4.  Modular sleeves with ceramic heads in isolated acetabular cup revision in younger patients-laboratory and experimental analysis of suitability and clinical outcomes.

Authors:  Peter Helwig; Lukas Konstantinidis; Anja Hirschmüller; Anke Bernstein; Oliver Hauschild; Norbert P Südkamp; Björn G Ochs
Journal:  Int Orthop       Date:  2012-12-07       Impact factor: 3.075

5.  The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty.

Authors:  Sulaiman A Almousa; Nelson V Greidanus; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

6.  What Is the Natural History of Asymptomatic Pseudotumors in Metal-on-metal THAs at Mid-term Followup?

Authors:  Sujith Konan; Clive P Duncan; Bassam S Masri; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

7.  What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Authors:  Nick Bayley; Habeeb Khan; Paul Grosso; Thomas Hupel; David Stevens; Matthew Snider; Emil Schemitsch; Paul Kuzyk
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

8.  Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis?

Authors:  Gabrielle S Donahue; Viktor Lindgren; Vincent P Galea; Rami Madanat; Orhun Muratoglu; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2016-04-27       Impact factor: 4.176

9.  Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

Authors:  Robin Pourzal; Deborah J Hall; Nguyen Q Ha; Robert M Urban; Brett R Levine; Joshua J Jacobs; Hannah J Lundberg
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

10.  [Update on metal-on-metal hip joints].

Authors:  K-P Günther; J Lützner; F Hannemann; J Schmitt; S Kirschner; J Goronzy; M Stiehler; C Lohmann; A Hartmann
Journal:  Orthopade       Date:  2013-05       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.