Literature DB >> 23221904

Relationship of central corneal thickness and intraocular pressure by iCare rebound tonometer.

Aparna Rao1, Mukesh Kumar, B Prakash, Gopal Varshney.   

Abstract

PURPOSE: To evaluate the relationship between central corneal thickness and intraocular pressure (IOP) measured by iCare rebound tonometry (RBT) in normals and glaucomatous patients.
METHODS: Of 102 patients screened, we included 62 eyes with glaucoma and 77 normal eyes in this hospital-based cross-sectional study. IOP was measured with RBT which averages 6 readings followed by Goldmann applanation tonometry (GAT). Central corneal thickness (CCT) was obtained by ultrasound pachymetry with an average of 5 consecutive readings. Relationship between RBT and CCT was studied by regression techniques using clustered data.
RESULTS: A total of 62 eyes of 33 patients with known glaucoma and 77 eyes of 40 normal patients (male: female=72.6%:27.4%) with a mean age of 51±17.7 years were included. The mean CCT was 531±32.9 μm (range, 448 to 626 μm). The median deviation of iCare RBT from GAT was 1 mm Hg (range, -7 to 20 mm Hg), which was not statistically different between normals and glaucomatous patients. The difference in IOP obtained by the 2 measurements (RBT-GAT) was found to be significantly influenced by CCT in all eyes combined (β=0.04, P=0.01).and in glaucomatous eyes (β=0.06, P=0.01) increasing maximally by 1 mm Hg for every 10 μm increase in corneal thickness in those with glaucoma. Comparing the difference between eyes with different corneal thickness, the influence was seen maximally in glaucomatous eyes with cornea thicker than 531 μm, (β=2.3, P=0.03).
CONCLUSIONS: Difference of IOP obtained by RBT and GAT increases with increasing CCT. Consideration of this must be kept in mind while using rebound tonometer for IOP recording in glaucomatous patients.

Entities:  

Mesh:

Year:  2014        PMID: 23221904     DOI: 10.1097/IJG.0b013e318279b819

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  16 in total

1.  Comparison of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes.

Authors:  Fatih Özcura; Nilgün Yildirim; Afsun Şahin; Ertuğrul Çolak
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

2.  Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.

Authors:  Senay Asik Nacaroglu; Emine Seker Un; Mehmet Giray Ersoz; Yelda Tasci
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

3.  Distribution of intraocular pressure and its determinants in an Iranian adult population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Abbasali Yekta; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2016-08-18       Impact factor: 1.779

4.  Intraocular pressure with rebound tonometry and effects of topical intraocular pressure reducing medications in guinea pigs.

Authors:  Yue Di; Xiu-Mei Luo; Tong Qiao; Na Lu
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

5.  Measurement of Intraocular Pressure by Patients With Glaucoma.

Authors:  Savva Pronin; Lyndsay Brown; Roly Megaw; Andrew J Tatham
Journal:  JAMA Ophthalmol       Date:  2017-10-01       Impact factor: 7.389

6.  Assessing the True Intraocular Pressure in the Non-human Primate.

Authors:  Faith McAllister; Ronald Harwerth; Nimesh Patel
Journal:  Optom Vis Sci       Date:  2018-02       Impact factor: 1.973

7.  Purinergic dysregulation causes hypertensive glaucoma-like optic neuropathy.

Authors:  Youichi Shinozaki; Kenji Kashiwagi; Kazuhiko Namekata; Akiko Takeda; Nobuhiko Ohno; Bernard Robaye; Takayuki Harada; Takeshi Iwata; Schuichi Koizumi
Journal:  JCI Insight       Date:  2017-10-05

8.  Wound stability and surgically induced corneal astigmatism after transconjunctival single-plane sclerocorneal incision cataract surgery.

Authors:  Ken Hayashi; Soichiro Ogawa; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2016-10-06       Impact factor: 2.447

9.  The utility of rebound tonometer in late elderly subjects.

Authors:  Rei Sakata; Jiro Numaga
Journal:  Clin Interv Aging       Date:  2014-01-22       Impact factor: 4.458

10.  Comprasion of ICare rebound tonometer and Goldmann applanation tonometer in high myopia.

Authors:  Halil Huseyin Cagatay; Metin Ekinci; Zeliha Yazar; Gokcen Gokce; Erdinc Ceylan
Journal:  ScientificWorldJournal       Date:  2014-10-14
View more