Literature DB >> 23221109

Gauging the likelihood of stable cavitation from ultrasound contrast agents.

Kenneth B Bader1, Christy K Holland.   

Abstract

The mechanical index (MI) was formulated to gauge the likelihood of adverse bioeffects from inertial cavitation. However, the MI formulation did not consider bubble activity from stable cavitation. This type of bubble activity can be readily nucleated from ultrasound contrast agents (UCAs) and has the potential to promote beneficial bioeffects. Here, the presence of stable cavitation is determined numerically by tracking the onset of subharmonic oscillations within a population of bubbles for frequencies up to 7 MHz and peak rarefactional pressures up to 3 MPa. In addition, the acoustic pressure rupture threshold of an UCA population was determined using the Marmottant model. The threshold for subharmonic emissions of optimally sized bubbles was found to be lower than the inertial cavitation threshold for all frequencies studied. The rupture thresholds of optimally sized UCAs were found to be lower than the threshold for subharmonic emissions for either single cycle or steady state acoustic excitations. Because the thresholds of both subharmonic emissions and UCA rupture are linearly dependent on frequency, an index of the form I(CAV) = P(r)/f (where P(r) is the peak rarefactional pressure in MPa and f is the frequency in MHz) was derived to gauge the likelihood of subharmonic emissions due to stable cavitation activity nucleated from UCAs.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23221109      PMCID: PMC4467591          DOI: 10.1088/0031-9155/58/1/127

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  49 in total

Review 1.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

2.  The behaviour of individual contrast agent microbubbles.

Authors:  V Sboros; C M Moran; S D Pye; W N McDicken
Journal:  Ultrasound Med Biol       Date:  2003-05       Impact factor: 2.998

3.  Noninvasive estimation of dynamic pressures in vitro and in vivo using the subharmonic response from microbubbles.

Authors:  Jaydev K Dave; Valgerdur G Halldorsdottir; John R Eisenbrey; Ji-Bin Liu; Maureen E McDonald; Kris Dickie; Corina Leung; Flemming Forsberg
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-10       Impact factor: 2.725

4.  On the relationship between encapsulated ultrasound contrast agent and pressure.

Authors:  Dan Adam; Michal Sapunar; Elina Burla
Journal:  Ultrasound Med Biol       Date:  2005-05       Impact factor: 2.998

5.  In vivo destruction of ultrasound contrast microbubbles is independent of the mechanical index.

Authors:  Flemming Forsberg; Daniel A Merton; Barry B Goldberg
Journal:  J Ultrasound Med       Date:  2006-01       Impact factor: 2.153

6.  A model for the dynamics of gas bubbles in soft tissue.

Authors:  Xinmai Yang; Charles C Church
Journal:  J Acoust Soc Am       Date:  2005-12       Impact factor: 1.840

7.  Encapsulated contrast microbubble radial oscillation associated with postexcitation pressure peaks.

Authors:  M D Santin; D A King; J Foiret; A Haak; W D O'Brien; S L Bridal
Journal:  J Acoust Soc Am       Date:  2010-02       Impact factor: 1.840

8.  A survey of the acoustic output of ultrasonic Doppler equipment.

Authors:  F A Duck; H C Starritt; S P Anderson
Journal:  Clin Phys Physiol Meas       Date:  1987-02

9.  MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh.

Authors:  S D Sokka; R King; K Hynynen
Journal:  Phys Med Biol       Date:  2003-01-21       Impact factor: 3.609

10.  Characterization of ultrasound propagation through ex-vivo human temporal bone.

Authors:  Azzdine Y Ammi; T Douglas Mast; I-Hua Huang; Todd A Abruzzo; Constantin-C Coussios; George J Shaw; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2008-05-23       Impact factor: 2.998

View more
  49 in total

1.  Transcranial cavitation detection in primates during blood-brain barrier opening--a performance assessment study.

Authors:  Shih-Ying Wu; Yao-Sheng Tung; Fabrice Marquet; Matthew Downs; Carlos Sanchez; Cherry Chen; Vincent Ferrera; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-06       Impact factor: 2.725

2.  Efficacy of histotripsy combined with rt-PA in vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Himanshu Shekhar; Adam D Maxwell; Tao Peng; David D McPherson; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

3.  Characterization of cavitation-radiated acoustic power using diffraction correction.

Authors:  Kyle T Rich; Christy K Holland; Marepalli B Rao; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2018-12       Impact factor: 1.840

Review 4.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

Review 5.  Sonothrombolysis.

Authors:  Kenneth B Bader; Guillaume Bouchoux; Christy K Holland
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

6.  Effect of Temperature on the Size Distribution, Shell Properties, and Stability of Definity®.

Authors:  Himanshu Shekhar; Nathaniel J Smith; Jason L Raymond; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2017-11-22       Impact factor: 2.998

7.  Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound.

Authors:  Matthew J Gruber; Kenneth B Bader; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2014-02       Impact factor: 1.840

Review 8.  Focused Ultrasound for Immunomodulation of the Tumor Microenvironment.

Authors:  Jordan B Joiner; Yuliya Pylayeva-Gupta; Paul A Dayton
Journal:  J Immunol       Date:  2020-11-01       Impact factor: 5.422

9.  In vitro thrombolytic efficacy of echogenic liposomes loaded with tissue plasminogen activator and octafluoropropane gas.

Authors:  Himanshu Shekhar; Kenneth B Bader; Shenwen Huang; Tao Peng; Shaoling Huang; David D McPherson; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-12-21       Impact factor: 3.609

Review 10.  Ultrasound-mediated drug delivery for cardiovascular disease.

Authors:  Jonathan T Sutton; Kevin J Haworth; Gail Pyne-Geithman; Christy K Holland
Journal:  Expert Opin Drug Deliv       Date:  2013-03-01       Impact factor: 6.648

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.