| Literature DB >> 23213335 |
A Astvaldsdóttir1, K Ahlund, W P Holbrook, B de Verdier, S Tranæus.
Abstract
The aim of the present study was to compare the diagnostic accuracy/efficacy of digital imaging fiber-optic transillumination (DIFOTI) with film and digital radiography, in detection of approximal caries lesions. One hundred and twelve approximal surfaces were scored for caries, using DIFOTI images film and digital radiographs. All three sets of images were examined twice by 8 observers, with a minimal interval of one week between examinations. Validation of histological sections served as a reference standard. Reproducibility, based on intra- and interobserver agreement, was similar for all three methods. At diagnostic threshold D1 (enamel and dentin caries), DIFOTI showed significantly higher sensitivity, but differences in specificity between methods were nonsignificant. Diagnostic accuracy in the form of area under the receiver operating characteristic curve (AUC) was significantly higher for DIFOTI. At diagnostic threshold D3 (dentin caries), the differences in sensitivity and AUC among methods were nonsignificant, but DIFOTI showed significantly lower specificity. Compared with the radiographs, DIFOTI showed closer agreement, expressed as weighted kappa values, with the reference standard. The results show that under in vitro conditions, the diagnostic accuracy of DIFOTI in detecting early approximal enamel lesions is greater than that of film and digital radiography, while the potential for detecting lesions in dentin is similar for all three methods.Entities:
Year: 2012 PMID: 23213335 PMCID: PMC3508587 DOI: 10.1155/2012/326401
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Figure 1The mean percentage of each detection score for each method, compared to the distribution of the reference standard (RS).
Figure 2ROC curves for the three methods based on results from 8 observers at the diagnostic threshold D1 (enamel and dentin caries).
Figure 3ROC curves for the three methods based on results from 8 observers at the diagnostic threshold D3 (dentin caries).
Reproducibility of the three diagnostic methods, in form of intra-examiner agreement presented as mean κ , and inter-examiner agreement presented as range of mean κ based on results from the eight observers.
| Method | Intra-observer agreement | Inter-observer agreement |
|---|---|---|
| DIFOTI | 0.82 | 0.62–0.76 |
| Film radiography | 0.82 | 0.63–0.78 |
| Digital radiography | 0.79 | 0.67–0.78 |
Examiner performance in detecting approximal caries lesions at two different diagnostic thresholds, expressed as sensitivity, specificity and AUC: area under the receiver operating characteristic (ROC) curve. Confidence interval of 95% is presented in brackets (CI 95%).
| Method of examination | Sensitivity | Specificity | AUC (CI 95%) | |||
|---|---|---|---|---|---|---|
| Cut off 1 | Cut off 2 | Cut off 1 | Cut off 2 | Cut off 1 | Cut off 2 | |
| Examiner 1 | ||||||
| DIFOTI | 0.65 | 0.33 | 0.91 | 0.95 | 0.79* (0.72–0.86) | 0.80* (0.68–0.92) |
| Film | 0.30 | 0.48 | 0.97 | 1.0 | 0.64* (0.58–0.70) | 0.92* (0.82–1.00) |
| Digital | 0.30 | 0.40 | 0.94 | 0.95 | 0.62* (0.54–0.69) | 0.82* (0.69–0.94) |
| Examiner 2 | ||||||
| DIFOTI | 0.83 | 0.73 | 0.85 | 0.90 | 0.87* (0.81–0.94) | 0.90* (0.83–0.98) |
| Film | 0.33 | 0.53 | 0.82 | 0.91 | 0.57 (0.48–0.66) | 0.87* (0.77–0.97) |
| Digital | 0.22 | 0.53 | 0.82 | 0.92 | 0.52 (0.44–0.61) | 0.79* (0.65–0.92) |
| Examiner 3 | ||||||
| DIFOTI | 0.62 | 0.60 | 0.94 | 0.94 | 0.79* (0.73–0.86) | 0.86* (0.74–0.98) |
| Film | 0.29 | 0.47 | 0.88 | 0.98 | 0.59* (0.51–0.66) | 0.79* (0.65–0.93) |
| Digital | 0.35 | 0.47 | 0.97 | 0.99 | 0.66* (0.60–0.73) | 0.80* (0.66–0.94) |
| Examiner 4 | ||||||
| DIFOTI | 0.46 | 0.33 | 1.0 | 1.0 | 0.73* (0.67–0.79) | 0.89* (0.79–1.00) |
| Film | 0.13 | 0.27 | 1.0 | 0.99 | 0.56* (0.52–0.60) | 0.65* (0.52–0.78) |
| Digital | 0.24 | 0.40 | 0.97 | 0.99 | 0.60* (0.54–0.66) | 0.78* (0.64–0.92) |
| Examiner 5 | ||||||
| DIFOTI | 0.89 | 0.40 | 0.68 | 0.95 | 0.83* (0.75–0.91) | 0.89* (0.83–0.96) |
| Film | 0.27 | 0.40 | 0.85 | 0.99 | 0.56 (0.48–0.64) | 0.79* (0.66–0.93) |
| Digital | 0.43 | 0.60 | 1.0 | 1.0 | 0.71* (0.65–0.78) | 0.98* (0.95–1.00) |
| Examiner 6 | ||||||
| DIFOTI | 0.89 | 0.93 | 0.65 | 0.87 | 0.88* (0.82–0.94) | 0.95* (0.91–0.99) |
| Film | 0.60 | 0.47 | 0.56 | 1.0 | 0.63* (0.53–0.73) | 0.88* (0.77–0.98) |
| Digital | 0.64 | 0.47 | 0.74 | 0.96 | 0.71* (0.61–0.80) | 0.88* (0.77–0.98) |
| Examiner 7 | ||||||
| DIFOTI | 0.71 | 0.60 | 0.91 | 0.82 | 0.82* (0.74–0.89) | 0.83* (0.72–0.93) |
| Film | 0.38 | 0.47 | 0.94 | 0.96 | 0.65* (0.58–0.73) | 0.88* (0.78–0.99) |
| Digital | 0.40 | 0.47 | 0.91 | 0.95 | 0.65* (0.57–0.73) | 0.90* (0.82–0.99) |
| Examiner 8 | ||||||
| DIFOTI | 0.62 | 0.67 | 1.0 | 0.99 | 0.81* (0.75–0.87) | 0.91* (0.82–1.00) |
| Film | 0.33 | 0.53 | 0.91 | 0.99 | 0.62* (0.55–0.70) | 0.87* (0.75–0.99) |
| Digital | 0.35 | 0.47 | 0.94 | 0.99 | 0.64* (0.57–0.72) | 0.79* (0.65–0.94) |
Cut-off 1: Diagnostic threshold D1; enamel and dentin caries lesions.
Cut-off 2: Diagnostic threshold D3; dentin caries lesions.
*Statistically significant P < 0.05.
Comparison of methods by Wilcoxon matched pairs test. The table presents P-values.
| DIFOTI-film | DIFOTI-digital | Film-digital | ||
|---|---|---|---|---|
| Cut off 1 | Sensitivity | 0.0117 | 0.0117 | 0.1762 |
| Specificity | 0.6726 | 0.6121 | 0.3525 | |
| AUC | 0.0117 | 0.0117 | 0.1508 | |
|
| ||||
| Cut off 2 | Sensitivity | 0.1282 | 0.1834 | 0.4652 |
| Specificity | 0.0346 | 0.0464 | 0.5294 | |
| AUC | 0.2626 | 0.2626 | 0.7353 | |
Agreement with reference standard. The table presents weighted kappa values.
| Method of examination | Examiners | |||||||
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
| DIFOTI | 0.56 | 0.75 | 0.68 | 0.57 | 0.65 | 0.75 | 0.60 | 0.73 |
| Film | 0.61 | 0.46 | 0.49 | 0.36 | 0.44 | 0.65 | 0.59 | 0.58 |
| Digital | 0.45 | 0.37 | 0.56 | 0.47 | 0.71 | 0.63 | 0.56 | 0.53 |
Figure 4Two sets of images (a) DIFOTI image and (b) digital radiograph of lesion with reference standard score 1. (c) DIFOTI image and (d) digital radiograph of lesion with reference standard score 3.