| Literature DB >> 32377327 |
Auste Antipoviene1, Monika Girijotaite2, Egle Aida Bendoraitiene3.
Abstract
OBJECTIVES: The aim of present prospective clinical trial was to assess the depth of clinically detected approximal caries lesions using digital imaging fiber-optic transillumination in comparison to periapical radiographs.Entities:
Keywords: dental caries; dental digital radiography; dental radiography; diagnostic imaging; transillumination
Year: 2020 PMID: 32377327 PMCID: PMC7191380 DOI: 10.5037/jomr.2020.11103
Source DB: PubMed Journal: J Oral Maxillofac Res ISSN: 2029-283X
Figure 1The example of digital radiograph (R2).
Radiographic scores used to classify depth of approximal carious lesions
| Score | Criterion |
|---|---|
|
| No demineralisation |
|
| Demineralisation confined to the outer half of the enamel |
|
| Demineralisation in the inner half of the enamel |
|
| Demineralisation broken enamel-dentine junction but without obvious spread in the dentine |
|
| Demineralisation with obvious spread in the outer half of the dentine |
|
| Demineralisation with obvious spread in the inner half of the dentine |
Digital imaging fiber-optic transillumination scores used to classify depth of approximal carious lesions
| Score | Criterion |
|---|---|
|
| No demineralisation |
|
| Demineralisation confined to the outer half of the enamel |
|
| Demineralisation in the inner half of the enamel |
|
| Demineralisation broken enamel-dentine junction but without obvious spread in the dentine |
|
| Demineralisation with obvious spread in the outer half of the dentine |
|
| Demineralisation with obvious spread in the inner half of the dentine |
Figure 2The example of digital imaging fibre optic transillumination (F3).
Figure 3Distribution of digital imaging fiber-optic transillumination (DIFOTI) measured demineralisation scores.
Different colours show the quantity of respective DIFOTI measured demineralisation score.
Figure 4Distribution of radiographically measured demineralisation scores.
Different colours show the quantity of respective radiographically measured demineralisation score.
Correlation between the diagnostic findings obtained by digital imaging fiber-optic transillumination and by digital radiography
| Scores | F0 | F1 | F2 | 3 | F3 | F4 |
|---|---|---|---|---|---|---|
| 0 | 0 | 0 | 0 | 0 | 2 | |
| 0 | 0 | 0 | 0 | 0 | 0 | |
| 1 | 0 | 0 | 1 | 1 | 1 | |
| 0 | 0 | 0 | 0 | 4 | 0 | |
| 1 | 0 | 2 | 1 | 9 | 3 | |
| 0 | 0 | 0 | 0 | 3 | 2 | |