Literature DB >> 23207535

Electromagnetic tracking navigation to guide radiofrequency ablation of a lung tumor.

Hayet Amalou1, Bradford J Wood.   

Abstract

Radiofrequency ablation (RFA) may be an option for patients with lung tumors who have unresectable disease and are not suitable for available palliative modalities. RFA electrode positioning may take several attempts, necessitating multiple imaging acquisitions or continuous use of computed tomography. Electromagnetic tracking uses miniature sensors integrated with RFA equipment to guide tools in real time, while referencing to preprocedure imaging. This technology was demonstrated successfully during a lung tumor ablation, and this was more accurate at targeting the tumor compared with traditional freehand needle insertion. It is possible, although speculative and anecdotal, that more accuracy could prevent unnecessary repositioning punctures and decrease radiation exposure. Electromagnetic tracking has theoretical potential to benefit minimally invasive interventions.

Entities:  

Mesh:

Year:  2012        PMID: 23207535      PMCID: PMC3568767          DOI: 10.1097/LBR.0b013e31827157c9

Source DB:  PubMed          Journal:  J Bronchology Interv Pulmonol        ISSN: 1948-8270


  8 in total

1.  Accuracy assessment protocols for electromagnetic tracking systems.

Authors:  D D Frantz; A D Wiles; S E Leis; S R Kirsch
Journal:  Phys Med Biol       Date:  2003-07-21       Impact factor: 3.609

2.  Respiratory motion compensation with tracked internal and external sensors during CT-guided procedures.

Authors:  Jörn Borgert; S Krüger; H Timinger; J Krücker; N Glossop; A Durrani; A Viswanathan; B J Wood
Journal:  Comput Aided Surg       Date:  2006-05

Review 3.  Technologies for guidance of radiofrequency ablation in the multimodality interventional suite of the future.

Authors:  Bradford J Wood; Julia K Locklin; Anand Viswanathan; Jochen Kruecker; Dieter Haemmerich; Juan Cebral; Ariela Sofer; Ruida Cheng; Evan McCreedy; Kevin Cleary; Matthew J McAuliffe; Neil Glossop; Jeff Yanof
Journal:  J Vasc Interv Radiol       Date:  2007-01       Impact factor: 3.464

Review 4.  A systematic review of radiofrequency ablation for lung tumors.

Authors:  Jacqui C Zhu; Tristan D Yan; David L Morris
Journal:  Ann Surg Oncol       Date:  2008-03-27       Impact factor: 5.344

Review 5.  Lung cancer and radiofrequency ablation.

Authors:  Steven C Rose; Patricia A Thistlethwaite; Patrick E Sewell; Ralph B Vance
Journal:  J Vasc Interv Radiol       Date:  2006-06       Impact factor: 3.464

6.  Needle biopsy of anatomically unfavorable liver lesions with an electromagnetic navigation assist device in a computed tomography environment.

Authors:  Filip Banovac; Emmanuel Wilson; Hui Zhang; Kevin Cleary
Journal:  J Vasc Interv Radiol       Date:  2006-10       Impact factor: 3.464

7.  Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study.

Authors:  Bradford J Wood; Hui Zhang; Amir Durrani; Neil Glossop; Sohan Ranjan; David Lindisch; Eliott Levy; Filip Banovac; Joern Borgert; Sascha Krueger; Jochen Kruecker; Anand Viswanathan; Kevin Cleary
Journal:  J Vasc Interv Radiol       Date:  2005-04       Impact factor: 3.464

8.  Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy.

Authors:  Jochen Krücker; Sheng Xu; Neil Glossop; Anand Viswanathan; Jörn Borgert; Heinrich Schulz; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2007-09       Impact factor: 3.464

  8 in total
  3 in total

Review 1.  Virtually no thoracic lesion inaccessible: a pictorial case review.

Authors:  Bradley B Pua; David Li; Brian W Sullivan; David C Madoff
Journal:  Semin Intervent Radiol       Date:  2013-06       Impact factor: 1.513

2.  Electromagnetic Real Time Navigation in the Region of the Posterior Pelvic Ring: An Experimental In-Vitro Feasibility Study and Comparison of Image Guided Techniques.

Authors:  Miguel Pishnamaz; Christoph Wilkmann; Hong-Sik Na; Jochen Pfeffer; Christoph Hänisch; Max Janssen; Philipp Bruners; Philipp Kobbe; Frank Hildebrand; Thomas Schmitz-Rode; Hans-Christoph Pape
Journal:  PLoS One       Date:  2016-02-10       Impact factor: 3.240

3.  Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study.

Authors:  Yu Tian; Cong Wang; Weiming Yue; Ming Lu; Hui Tian
Journal:  Sci Rep       Date:  2020-12-08       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.