Fast spin-echo imaging of the abdomen during breath-holding: an alternative to RASE and other fast imaging techniques.

R C Nelson1, J L Chezmar.   

Abstract

We have developed a rapidly acquired T1-weighted spin-echo pulse sequence that uses gradient echo-like parameters of TR 70 ms, TE 10 ms, NEX-1 (SE 70/10/1) with large pulse angles, and presaturation. This sequence yields two images of the abdomen during a comfortable breath-hold of 9 s. Preliminary phantom studies with this sequence demonstrated that peak signal-to-noise ratios occurred at pulse angles of 120 degrees and 135 degrees. Compared to this rapidly acquired sequence, a conventional T1-weighted spin-echo sequence of TR 140 ms, TE 10 ms, NEX-4 demonstrated 2.8 times the signal-to-noise ratio, 2.6 times the liver-spleen contrast-to-noise ratio but only 1.6 times the contrast-to-artifact ratio. When normalized for the imaging time, however, there was little difference in the signal-to-noise and contrast-to-noise ratios, although the SE 70/10/1 demonstrated 2.0 times the contrast-to-artifact ratio. We conclude that for abdominal imaging the SE 70/10/1 is an excellent alternative to RASE and other fast imaging techniques, and, although there are inherently low signal-to-noise ratios, it may be particularly useful when coupled with a paramagnetic contrast agent.

Entities:  

Mesh:

Year:  1992        PMID: 1426843     DOI: 10.1007/bf01888573

Source DB:  PubMed          Journal:  Gastrointest Radiol        ISSN: 0364-2356


  21 in total

1.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

2.  Strategies to improve contrast in turboFLASH imaging: reordered phase encoding and k-space segmentation.

Authors:  D Chien; D J Atkinson; R R Edelman
Journal:  J Magn Reson Imaging       Date:  1991 Jan-Feb       Impact factor: 4.813

3.  Differentiation of hepatic hemangiomas from metastases by dynamic contrast-enhanced MR imaging.

Authors:  B Hamm; E Fischer; M Taupitz
Journal:  J Comput Assist Tomogr       Date:  1990 Mar-Apr       Impact factor: 1.826

4.  Snapshot imaging at 0.5 T using echo-planar techniques.

Authors:  R J Ordidge; A Howseman; R Coxon; R Turner; B Chapman; P Glover; M Stehling; P Mansfield
Journal:  Magn Reson Med       Date:  1989-05       Impact factor: 4.668

5.  Instant images of the body by magnetic resonance.

Authors:  I L Pykett; R R Rzedzian
Journal:  Magn Reson Med       Date:  1987-12       Impact factor: 4.668

6.  Dynamic spin-echo MRI of liver cancer using Gadolinium-DTPA: animal investigation.

Authors:  S Saini; D D Stark; T J Brady; J Wittenberg; J T Ferrucci
Journal:  AJR Am J Roentgenol       Date:  1986-08       Impact factor: 3.959

7.  Single breath-holding scans of the abdomen using FISP and FLASH at 1.5 T.

Authors:  E C Unger; M S Cohen; R A Gatenby; M R Clair; T R Brown; S J Nelson; J S McGlone
Journal:  J Comput Assist Tomogr       Date:  1988 Jul-Aug       Impact factor: 1.826

8.  Fast spin echo imaging with suspended respiration: gadolinium enhanced MR imaging of liver tumors.

Authors:  I Mano; H Yoshida; K Nakabayashi; N Yashiro; M Iio
Journal:  J Comput Assist Tomogr       Date:  1987 Jan-Feb       Impact factor: 1.826

9.  MR image contrast and relaxation times of solid tumors in the chest, abdomen, and pelvis.

Authors:  H C Schmidt; D Tscholakoff; H Hricak; C B Higgins
Journal:  J Comput Assist Tomogr       Date:  1985 Jul-Aug       Impact factor: 1.826

10.  Hepatic tumors: magnetic resonance and CT appearance.

Authors:  A A Moss; H I Goldberg; D B Stark; P L Davis; A R Margulis; L Kaufman; L E Crooks
Journal:  Radiology       Date:  1984-01       Impact factor: 11.105

View more
  1 in total

1.  Breathhold imaging of the upper abdomen using a circular polarized-array coil: comparison with standard body coil imaging.

Authors:  J Gauger; N G Holzknecht; C A Lackerbauer; H Sittek; K E Fiedler; R Petsch; M Reiser
Journal:  MAGMA       Date:  1996-06       Impact factor: 2.310

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.