Literature DB >> 23197471

Towards a five-minute comprehensive cardiac MR examination using highly accelerated parallel imaging with a 32-element coil array: feasibility and initial comparative evaluation.

Jian Xu1, Daniel Kim, Ricardo Otazo, Monvadi B Srichai, Ruth P Lim, Leon Axel, Kelly Anne Mcgorty, Thoralf Niendorf, Daniel K Sodickson.   

Abstract

PURPOSE: To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE).
MATERIALS AND METHODS: This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers.
RESULTS: Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE.
CONCLUSION: This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  breath-hold; cardiovascular MRI; parallel imaging; volumetric; whole heart

Mesh:

Year:  2012        PMID: 23197471      PMCID: PMC3615039          DOI: 10.1002/jmri.23955

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  35 in total

1.  Coronary artery magnetic resonance angiography (MRA): a comparison between the whole-heart and volume-targeted methods using a T2-prepared SSFP sequence.

Authors:  Xiaoming Bi; Vibhas Deshpande; James Carr; Debiao Li
Journal:  J Cardiovasc Magn Reson       Date:  2006       Impact factor: 5.364

2.  Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system.

Authors:  Thoralf Niendorf; Christopher J Hardy; Randy O Giaquinto; Patrick Gross; Harvey E Cline; Yudong Zhu; Gontran Kenwood; Shmuel Cohen; Aaron K Grant; Sanjay Joshi; Neil M Rofsky; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

3.  Rapid detection of myocardial infarction by subsecond, free-breathing delayed contrast-enhancement cardiovascular magnetic resonance.

Authors:  Burkhard Sievers; Michael D Elliott; Lynne M Hurwitz; Timothy S E Albert; Igor Klem; Wolfgang G Rehwald; Michele A Parker; Robert M Judd; Raymond J Kim
Journal:  Circulation       Date:  2007-01-02       Impact factor: 29.690

Review 4.  Imaging sequences for first pass perfusion --a review.

Authors:  Peter Kellman; Andrew E Arai
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

Review 5.  How we perform myocardial perfusion with cardiovascular magnetic resonance.

Authors:  Rolf Gebker; Jürg Schwitter; Eckart Fleck; Eike Nagel
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

6.  Contrast-dose relation in first-pass myocardial MR perfusion imaging.

Authors:  Wolfgang Utz; Thoralf Niendorf; Ralf Wassmuth; Daniel Messroghli; Rainer Dietz; Jeanette Schulz-Menger
Journal:  J Magn Reson Imaging       Date:  2007-06       Impact factor: 4.813

7.  High temporal resolution breathheld 3D FIESTA CINE imaging: validation of ventricular function in patients with chronic myocardial infarction.

Authors:  Dan W Rettmann; Manojkumar Saranathan; Katherine C Wu; Clerio F Azevedo; David A Bluemke; Thomas K F Foo
Journal:  J Magn Reson Imaging       Date:  2007-06       Impact factor: 4.813

8.  Improved k-t BLAST and k-t SENSE using FOCUSS.

Authors:  Hong Jung; Jong Chul Ye; Eung Yeop Kim
Journal:  Phys Med Biol       Date:  2007-05-10       Impact factor: 3.609

9.  Whole-heart cine MRI using real-time respiratory self-gating.

Authors:  Sergio Uribe; Vivek Muthurangu; Redha Boubertakh; Tobias Schaeffter; Reza Razavi; Derek L G Hill; Michael S Hansen
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

10.  Four-dimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass.

Authors:  Cosima Jahnke; Eike Nagel; Rolf Gebker; Axel Bornstedt; Bernhard Schnackenburg; Sebastian Kozerke; Eckart Fleck; Ingo Paetsch
Journal:  J Magn Reson Imaging       Date:  2007-04       Impact factor: 4.813

View more
  11 in total

Review 1.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

Review 2.  Will MRI of gastrointestinal function parallel the clinical success of cine cardiac MRI?

Authors:  Caroline Hoad; Christopher Clarke; Luca Marciani; Martin John Graves; Maura Corsetti
Journal:  Br J Radiol       Date:  2018-10-24       Impact factor: 3.039

3.  5D whole-heart sparse MRI.

Authors:  Li Feng; Simone Coppo; Davide Piccini; Jerome Yerly; Ruth P Lim; Pier Giorgio Masci; Matthias Stuber; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2017-05-11       Impact factor: 4.668

4.  Late gadolinium enhancement cardiac imaging on a 3T scanner with parallel RF transmission technique: prospective comparison of 3D-PSIR and 3D-IR.

Authors:  Anthony Schultz; Thibault Caspar; Mickaël Schaeffer; Aïssam Labani; Mi-Young Jeung; Soraya El Ghannudi; Catherine Roy; Mickaël Ohana
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

5.  Complete Free-breathing Adenosine Stress Cardiac MRI Using Compressed Sensing and Motion Correction: Comparison of Functional Parameters, Perfusion, and Late Enhancement with the Standard Breath-holding Examination.

Authors:  Christoph Treutlein; Marco Wiesmüller; Matthias S May; Rafael Heiss; Tobias Hepp; Michael Uder; Wolfgang Wuest
Journal:  Radiol Cardiothorac Imaging       Date:  2019-08-22

Review 6.  Performance of Cardiac MRI in Pediatric and Adult Patients with Fontan Circulation.

Authors:  Filippo Puricelli; Inga Voges; Peter Gatehouse; Michael Rigby; Cemil Izgi; Dudley J Pennell; Sylvia Krupickova
Journal:  Radiol Cardiothorac Imaging       Date:  2022-06-02

7.  Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T.

Authors:  Masahiro Takakado; Tomoyuki Kido; Ryo Ogawa; Yoshihiro Takimoto; Tsuyoshi Tokuda; Yuki Tanabe; Naoto Kawaguchi; Jianing Pang; Yoshiaki Komori; Teruhito Kido
Journal:  Jpn J Radiol       Date:  2022-10-13       Impact factor: 2.701

Review 8.  Accelerated MRI for the assessment of cardiac function.

Authors:  Leon Axel; Ricardo Otazo
Journal:  Br J Radiol       Date:  2016-04-21       Impact factor: 3.039

Review 9.  Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.

Authors:  Alice C Yang; Madison Kretzler; Sonja Sudarski; Vikas Gulani; Nicole Seiberlich
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

10.  Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.

Authors:  Lukas Winter; Celal Özerdem; Werner Hoffmann; Davide Santoro; Alexander Müller; Helmar Waiczies; Reiner Seemann; Andreas Graessl; Peter Wust; Thoralf Niendorf
Journal:  PLoS One       Date:  2013-04-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.