Andrea M Andrade1, Eugenio Garcia, Sandra Kiss Moura, Alessandra Reis, Alessandro Loguercio, Luciana Mendonça Silva, Gustavo H D Pimentel, Rosa Helena Miranda Grande.
Abstract
Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey's tests. Groups 1 and 2 resulted in statistically similar mean μSBS (P > 0.05); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (P < 0.05). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values.Entities:
Year: 2012 PMID: 23193406 PMCID: PMC3502005 DOI: 10.1155/2012/618960
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Materials, batch number, composition, and mode of application.
| Materials/batch number | Composition | Mode of application |
|---|---|---|
| Adper single bond [7 MR] | Bis-GMA, HEMA, dimethacrylates, polyalkenoic acid copolymer, initiators, water, and ethanol | (1) Apply phosphoric acid to dentin for 15 s |
| (2) Rinse for 15 s | ||
| (3) Keep dentin wet | ||
| (4) Apply two consecutive coats of adhesive for 15 s with gently agitation | ||
| (5) Gently air for 5 s to evaporate the solvent (10 cm, 45° inclination with 1-bar pressure) | ||
| (6) Light polymerize for 10 s | ||
|
| ||
| XP Bond [0710004024] | TCB-resin, PENTA,UDMA, TEGDMA, HEMA, butylated benzenediol, ethyl-4-dimethylaminobenzoate, camphorquinone, nanofiller, t-butanol | (1) Apply phosphoric acid to dentin for 15 s |
| (2) Rinse for 15 s | ||
| (3) Apply the adhesive, and leave undisturbed for 20 seconds | ||
| (4) Gently air for 5 s to evaporate the solvent (10 cm, 45° inclination with 1-bar pressure) | ||
| (5) Light polymerize for 20 s | ||
|
| ||
| Filtek Z250 [7 WN] | (1) Filler type—zirconia, silica | (1) Light polymerize each increment for 40 s |
| (2) Resin—Bis-GMA, UDMA, and Bis-EMA | ||
Bis-GMA: 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropoxy)]-phenyl propane; HEMA: 2-hydroxyethylmethacrylate; TEGDMA: tryethyleneglycol dimethacrylate; UDMA: urethane dimethacrylate; TCB-resin: carboxylic acid-modified dimethacrylate; PENTA: phosphoric acid-modified acrylate resin; Bis-EMA: bisphenol-A, ethoxylate 0110 dimethacrylate.
Figure 1SEM photomicrographs showed adhesive (a) failure and mixed failure (b) and (c). In (b), observe a mixed failure between adhesive (A), dentin (D), and composite resin (R) and in (c) a mixed failure between composite resin (R) and adhesive (A).
Number of specimens (%) distributed according to the failure pattern for each experimental condition (*).
| Adhesive systems | Groups | Pattern failure (%) | ||||
|---|---|---|---|---|---|---|
| Adhesive | Mixed | Cohesive | PTF | |||
| Resin | Dentin | |||||
| Adper | 1 | 14 (56.0) | 5 (20.0) | 0 (0) | 0 (0) | 6 (24.0) |
| Single | 2 | 22 (91.7) | 2 (8.3) | 0 (0) | 0 (0) | 0 (0) |
| Bond | 3 | 15 (50.0) | 15 (50.0) | 0 (0) | 0 (0) | 0 (0) |
|
| ||||||
| XP Bond | 1 | 18 (69.2) | 0 (0) | 0 (0) | 0 (0) | 8 (30.8) |
| 2 | 26 (92.9) | 0 (0) | 0 (0) | 0 (0) | 2 (7.1) | |
| 3 | 22 (73.3) | 8 (26.7) | 0 (0) | 0 (0) | 0 (0) | |
Mean bond values and standard deviation (MPa) with and without PTF and according to each experimental condition (*).
| Adhesive | Groups | PTF inclusion | PTF exclusion |
|---|---|---|---|
| Adper single bond | 1 | 14.0 ± 5.7d | 14.8 ± 3.1D |
| 2 | 18.1 ± 3.6c, d | 18.1 ± 3.6C, D | |
| 3 | 37.7 ± 3.7a | 37.7 ± 3.7A | |
|
| |||
| XP bond | 1 | 14.7 ± 4.2d | 16.2 ± 4.2C, D |
| 2 | 19.7 ± 1.6c | 20.5 ± 1.1C | |
| 3 | 26.0 ± 4.4b | 26.0 ± 4.4B | |
(*) Lowercase letters indicated significant difference between “pretest (PTF) failure inclusion” (P < 0.05); capital letters indicated significant difference between “PTF exclusion” (P < 0.05).