Literature DB >> 23184166

Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography.

Isabela Maria de Carvalho Crusoé Silva1, Deborah Queiroz de Freitas, Glaucia Maria Bovi Ambrosano, Frab Norberto Bóscolo, Solange Maria Almeida.   

Abstract

The aim of this study was to evaluate the validity of the bone density value of potential implant sites in HU obtained by a specific cone-beam computed tomography (CBCT) device. In this study, the HU values obtained using a MSCT scanner were used as the gold standard. Twenty mandibles (40 potential implant sites) were scanned using an MSCT scanner (Somatom Sensation 40) and a CBCT scanner (i-CAT). The MSCT images were evaluated using the Syngo CT Workplace software and the CBCT images, using the XoranCat software. The images were evaluated twice by three oral radiologists, at 60 day intervals. The trabecular bone density of the same area was evaluated on both images. Intraclass coefficients (ICC) were calculated to examine the agreement between the examiners and between the two periods of evaluation. The bone density and area of the ROI were compared by the Student t test and Bland-Altman analysis. ICCs were excellent. The mean HU value obtained using CBCT (418.06) was higher than that obtained using MSCT (313.13), with a statistically significant difference (p < 0.0001). In addition, Bland-Altman analysis showed that the HU measures were not equivalent. In conclusion, the bone density in HU with CBCT images obtained using the device studied proved unreliable, since it was higher than that obtained using MSCT.

Mesh:

Substances:

Year:  2012        PMID: 23184166     DOI: 10.1590/s1806-83242012000600011

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  26 in total

1.  Hounsfield unit change in root and alveolar bone during canine retraction.

Authors:  Feifei Jiang; Sean S-Y Liu; Zeyang Xia; Shuning Li; Jie Chen; Katherine S Kula; George Eckert
Journal:  Am J Orthod Dentofacial Orthop       Date:  2015-04       Impact factor: 2.650

Review 2.  CBCT-based bone quality assessment: are Hounsfield units applicable?

Authors:  R Pauwels; R Jacobs; S R Singer; M Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

3.  Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts.

Authors:  Deborah Queiroz Freitas; Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Taruska Ventorini Vasconcelos; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

4.  Evaluation of the zygomatic bone by cone beam computed tomography.

Authors:  Helena Aguiar Ribeiro Nascimento; Maria Augusta Portella Guedes Visconti; Paulo de Tarso Silva Macedo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Surg Radiol Anat       Date:  2014-06-21       Impact factor: 1.246

5.  Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners.

Authors:  Matheus L Oliveira; Guilherme M Tosoni; David H Lindsey; Kristopher Mendoza; Sotirios Tetradis; Sanjay M Mallya
Journal:  Imaging Sci Dent       Date:  2014-11-25

Review 6.  Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis.

Authors:  Abirami Selvaraj; Ravindra Kumar Jain; Ravleen Nagi; Arthi Balasubramaniam
Journal:  Imaging Sci Dent       Date:  2022-05-13

7.  Clinical and radiographic evaluation of effect of risedronate 5 mg as an adjunct to treatment of chronic periodontitis in postmenopausal women (12-month study).

Authors:  N V Bhavsar; S R Trivedi; K Dulani; N Brahmbhatt; S Shah; D Chaudhri
Journal:  Osteoporos Int       Date:  2016-03-30       Impact factor: 4.507

8.  Sensitivity and Specificity of Computed Tomography in the Evaluation of Bone Mineral Density in Mexican Patients with Breast Cancer.

Authors:  Ana Amador Martínez; Eleazar Lara Padilla; Juan Antonio Pérez Rodríguez; Alfonso Alfaro; Dania Guadalupe Solis Cano; Cindy Bandala; Nancy Guzman
Journal:  Cureus       Date:  2019-08-28

9.  Can gray values be converted to Hounsfield units? A systematic review.

Authors:  Marjorie Eguren; Anderson Holguin; Karla Diaz; Jose Vidalon; Carlos Linan; Camila Pacheco-Pereira; Manuel Oscar Lagravere Vich
Journal:  Dentomaxillofac Radiol       Date:  2021-06-19       Impact factor: 2.419

10.  Radiographic evaluation of the symphysis menti as a donor site for an autologous bone graft in pre-implant surgery.

Authors:  Roberto Di Bari; Roberto Coronelli; Andrea Cicconetti
Journal:  Imaging Sci Dent       Date:  2013-09-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.