Measurement accuracy of heart rate and respiratory rate during graded exercise and sustained exercise in the heat using the Zephyr BioHarness.

J-H Kim1, R Roberge, J B Powell, A B Shafer, W Jon Williams.   

Abstract

The Zephyr BioHarness was tested to determine the accuracy of heart rate (HR) and respiratory rate (RR) measurements during 2 exercise protocols in conjunction with either a laboratory metabolic cart (Vmax) or a previously validated portable metabolic system (K4b2). In one protocol, HR and RR were measured using the BioHarness and Vmax during a graded exercise up to V˙O2max (n=12). In another protocol, HR and RR were measured using the BH and K4b2 during sustained exercise (30% and 50% V˙O2max for 20 min each) in a hot environment (30 °C, 50% relative humidity) (n=6). During the graded exercise, HR but not RR, obtained from the BioHarness was higher compared to the Vmax at baseline and 30% V˙O2max (p<0.05), but showed no significant difference at other stages with high correlation coefficients for both HR (r=0.87-0.96) and RR (r=0.90-0.99 above 30% V˙O2max). During the exercise in the heat, there were no significant differences between the BioHarness and K4b2 system. Correlation coefficients between the methods were low for HR but moderately to highly correlated (0.49-0.99) for RR. In conclusion, the BioHarness is comparable to Vmax and K4b2 over a wide range of V˙O2 during graded exercise and sustained exercise in the heat. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 23175181      PMCID: PMC4620538          DOI: 10.1055/s-0032-1327661

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  13 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Validation of the COSMED K4 b2 portable metabolic system.

Authors:  J E McLaughlin; G A King; E T Howley; D R Bassett; B E Ainsworth
Journal:  Int J Sports Med       Date:  2001-05       Impact factor: 3.118

3.  Update--Ethical standards in sport and exercise science research.

Authors:  D J Harriss; G Atkinson
Journal:  Int J Sports Med       Date:  2011-11-07       Impact factor: 3.118

4.  Accuracy of an infrared LED device to measure heart rate and energy expenditure during rest and exercise.

Authors:  C Matthew Lee; Mark Gorelick; Albert Mendoza
Journal:  J Sports Sci       Date:  2011-10-13       Impact factor: 3.337

Review 5.  The control of breathing in clinical practice.

Authors:  B Caruana-Montaldo; K Gleeson; C W Zwillich
Journal:  Chest       Date:  2000-01       Impact factor: 9.410

6.  The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage.

Authors:  Paris B Lovett; Jason M Buchwald; Kai Stürmann; Polly Bijur
Journal:  Ann Emerg Med       Date:  2005-01       Impact factor: 5.721

7.  Measurement of exercise ventilation by a portable respiratory inductive plethysmograph.

Authors:  Jonathan D Witt; Jason R K O Fisher; Jordan A Guenette; Krystie A Cheong; Brock J Wilson; A William Sheel
Journal:  Respir Physiol Neurobiol       Date:  2006-02-28       Impact factor: 1.931

8.  Physiological monitoring in firefighter ensembles: wearable plethysmographic sensor vest versus standard equipment.

Authors:  Aitor Coca; Raymond J Roberge; W Jon Williams; Douglas P Landsittel; Jeffrey B Powell; Andrew Palmiero
Journal:  J Occup Environ Hyg       Date:  2010-02       Impact factor: 2.155

Review 9.  Respiration rate monitoring methods: a review.

Authors:  F Q Al-Khalidi; R Saatchi; D Burke; H Elphick; S Tan
Journal:  Pediatr Pulmonol       Date:  2011-01-31

10.  The PEP transducer: a new way of measuring respiratory rate in the non-intubated patient.

Authors:  D Dodds; J Purdy; C Moulton
Journal:  J Accid Emerg Med       Date:  1999-01
View more
  31 in total

1.  Effect of wearing an N95 filtering facepiece respirator on superomedial orbital infrared indirect brain temperature measurements.

Authors:  Travis DiLeo; Raymond J Roberge; Jung-Hyun Kim
Journal:  J Clin Monit Comput       Date:  2016-01-13       Impact factor: 2.502

2.  Flow experience and the mobilization of attentional resources.

Authors:  Marcelo Felipe de Sampaio Barros; Fernando M Araújo-Moreira; Luis Carlos Trevelin; Rémi Radel
Journal:  Cogn Affect Behav Neurosci       Date:  2018-08       Impact factor: 3.282

3.  Inter-Instrument Reliability and Agreement of Fitbit Charge Measurements of Heart Rate and Activity at Rest, during the Modified Canadian Aerobic Fitness Test, and in Recovery.

Authors:  Goris Nazari; Joy C MacDermid; Kathryn E Sinden; Julie Richardson; Ada Tang
Journal:  Physiother Can       Date:  2019       Impact factor: 1.037

4.  Kick LL: A Smartwatch for Monitoring Respiration and Heart Rate using Photoplethysmography.

Authors:  Orlando S Hoilett; Ashlyn M Twibell; Rohit Srivastava; Jacqueline C Linnes
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

5.  The Role of Volume Regulation and Thermoregulation in AKI during Marathon Running.

Authors:  Sherry G Mansour; Thomas G Martin; Wassim Obeid; Rachel W Pata; Karen M Myrick; Lidiya Kukova; Yaqi Jia; Petter Bjornstad; Joe M El-Khoury; Chirag R Parikh
Journal:  Clin J Am Soc Nephrol       Date:  2019-08-14       Impact factor: 8.237

6.  The Effects Aerobic Fitness has on Heart Rate Responses for a Custody Assistant Recruit Class Performing a Formation Run.

Authors:  Karly A Rodas; Matthew R Moreno; Ashley M Bloodgood; J Jay Dawes; Joseph M Dulla; Robin M Orr; Robert G Lockie
Journal:  Int J Exerc Sci       Date:  2021-10-01

7.  The Impact of Accelerometer and Heart Rate Data on Hypoglycemia Mitigation in Type 1 Diabetes.

Authors:  Matthew Stenerson; Fraser Cameron; Darrell M Wilson; Breanne Harris; Shelby Payne; B Wayne Bequette; Bruce A Buckingham
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

8.  Treadmill exercise improves fitness and reduces craving and use of cocaine in individuals with concurrent cocaine and tobacco-use disorder.

Authors:  Richard De La Garza; Jin H Yoon; Daisy G Y Thompson-Lake; Colin N Haile; Joel D Eisenhofer; Thomas F Newton; James J Mahoney
Journal:  Psychiatry Res       Date:  2016-08-09       Impact factor: 3.222

9.  Prevalence of cardiac arrhythmias in a community based chiropractic practice.

Authors:  Suzanne Padhi; Nasreen Patel; Darcy Driscoll; Brian Budgell
Journal:  J Can Chiropr Assoc       Date:  2014-09

10.  Psychometric properties of the Zephyr bioharness device: a systematic review.

Authors:  Goris Nazari; Pavlos Bobos; Joy C MacDermid; Kathryn E Sinden; Julie Richardson; Ada Tang
Journal:  BMC Sports Sci Med Rehabil       Date:  2018-02-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.