Physiological monitoring in firefighter ensembles: wearable plethysmographic sensor vest versus standard equipment.

Aitor Coca1, Raymond J Roberge, W Jon Williams, Douglas P Landsittel, Jeffrey B Powell, Andrew Palmiero.   

Abstract

We evaluated the accuracy of a wearable sensor vest for real-time monitoring of physiological responses to treadmill exercise. Ten subjects in standard firefighter ensembles, treadmill exercising at 50% VO(2) max, had heart rate (HR), respiratory rate (RR), skin temperature (T(sk)), oxygen saturation (SaO(2)), tidal volume (V(T)), and minute ventilation (V(E)) recorded concurrently by a wearable plethysmographic sensor vest and standard laboratory physiological monitoring equipment for comparison. A high degree of correlation was noted for most of the measured variables [HR (r = 0.99), RR (r = 0.98), T(sk) (r = 0.98), V(E) (r = 0.88), and SaO(2) (r = 0.79)]. V(T) (r = 0.60) had a moderate correlation, although a paired differences analysis showed a mean paired difference of -0.03 L. This mean paired difference represents a 1.92% variation for V(T). Data from the wearable sensor vest is comparable to data captured from standard laboratory physiological monitoring equipment on subjects wearing standard firefighter ensembles while exercising at a moderate work rate. This study demonstrates the accuracy of the wearable sensor technology for these physiological parameters under these conditions and suggests that it could be useful for actual field studies of firefighters in traditional firefighting gear.

Mesh:

Substances:

Year:  2010        PMID: 20017053     DOI: 10.1080/15459620903455722

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  5 in total

Review 1.  Evolution and Applications of Recent Sensing Technology for Occupational Risk Assessment: A Rapid Review of the Literature.

Authors:  Giacomo Fanti; Andrea Spinazzè; Francesca Borghi; Sabrina Rovelli; Davide Campagnolo; Marta Keller; Andrea Borghi; Andrea Cattaneo; Emanuele Cauda; Domenico Maria Cavallo
Journal:  Sensors (Basel)       Date:  2022-06-27       Impact factor: 3.847

2.  Measurement accuracy of heart rate and respiratory rate during graded exercise and sustained exercise in the heat using the Zephyr BioHarness.

Authors:  J-H Kim; R Roberge; J B Powell; A B Shafer; W Jon Williams
Journal:  Int J Sports Med       Date:  2012-11-22       Impact factor: 3.118

3.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

4.  Hierarchical Network Enabled Flexible Textile Pressure Sensor with Ultrabroad Response Range and High-Temperature Resistance.

Authors:  Meiling Jia; Chenghan Yi; Yankun Han; Lei Wang; Xin Li; Guoliang Xu; Ke He; Nianci Li; Yuxin Hou; Zhongguo Wang; Yuanhao Zhu; Yuanao Zhang; Mingzhu Hu; Ran Sun; Peifei Tong; Jiawei Yang; Yougen Hu; Zhixun Wang; Weimin Li; Wenjie Li; Lei Wei; Chunlei Yang; Ming Chen
Journal:  Adv Sci (Weinh)       Date:  2022-03-14       Impact factor: 17.521

Review 5.  Human Vital Signs Detection Methods and Potential Using Radars: A Review.

Authors:  Mamady Kebe; Rida Gadhafi; Baker Mohammad; Mihai Sanduleanu; Hani Saleh; Mahmoud Al-Qutayri
Journal:  Sensors (Basel)       Date:  2020-03-06       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.