Literature DB >> 15635313

The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage.

Paris B Lovett1, Jason M Buchwald, Kai Stürmann, Polly Bijur.   

Abstract

STUDY
OBJECTIVE: Of all the vital signs, only respiratory rate is still measured clinically in most US triage systems. Previous studies have demonstrated the inaccuracy, poor interobserver agreement, and low variability of routine measurements of respiratory rate. We assess the variability and accuracy of triage nurses' measurements of respiratory rate against a criterion standard. Also, we assess electronic measurement of respiratory rate against the same criterion standard.
METHODS: Consecutive patients presenting to an urban teaching emergency department (ED) were enrolled in this prospective study. Electronic measurement of respiratory rate was recorded throughout the triage encounter when nurses were recording measurements of respiratory rate. Electronic respiratory rate was measured using transthoracic impedance plethysmography. Immediately after each triage evaluation, criterion standard measurements of respiratory rate were made by research assistants using the World Health Organization recommendation of auscultation or observation for 60 seconds.
RESULTS: We enrolled 159 patients. Variability was low for triage nurses' measurements of respiratory rate (SD 3.3) and electronic measurement of respiratory rate (SD 4.1) compared with criterion standard measurements of respiratory rate (SD 4.8; P <.05). Triage nurses' measurements of respiratory rate and electronic measurement of respiratory rate showed low sensitivity in detecting bradypnea and tachypnea. In a Bland-Altman analysis, triage nurses' measurements of respiratory rate and electronic measurement of respiratory rate showed poor agreement with criterion standard measurements of respiratory rate. Subgroup analysis of patients presenting with cardiac and respiratory symptoms yielded similar results.
CONCLUSION: Neither triage nurses nor an electronic monitor provides accurate measurements of respiratory rate in the ED. Emergency physicians should search for new electronic modalities for measuring respiratory rate to bring respiratory rate into line with other vital signs. Emergency physicians should also consider new clinical strategies for measuring respiratory rate.

Entities:  

Mesh:

Year:  2005        PMID: 15635313     DOI: 10.1016/j.annemergmed.2004.06.016

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  49 in total

1.  Predicting cardiac arrest on the wards: a nested case-control study.

Authors:  Matthew M Churpek; Trevor C Yuen; Michael T Huber; Seo Young Park; Jesse B Hall; Dana P Edelson
Journal:  Chest       Date:  2011-11-03       Impact factor: 9.410

2.  Monitoring the respiratory rate by miniature motion sensors in premature infants: a comparative study.

Authors:  S Kohn; D Waisman; J Pesin; A Faingersh; I C Klotzman; C Levy; G Hirshberg; A Rotschild; A Landesberg
Journal:  J Perinatol       Date:  2015-11-19       Impact factor: 2.521

3.  Routine vital signs not so routine: Next question? When does it matter?

Authors:  David McGillivray
Journal:  Paediatr Child Health       Date:  2006-04       Impact factor: 2.253

4.  Acoustic sensor versus electrocardiographically derived respiratory rate in unstable trauma patients.

Authors:  Shiming Yang; Ashley Menne; Peter Hu; Lynn Stansbury; Cheng Gao; Nicolas Dorsey; William Chiu; Stacy Shackelford; Colin Mackenzie
Journal:  J Clin Monit Comput       Date:  2016-06-07       Impact factor: 2.502

5.  Clinical evaluation of a novel respiratory rate monitor.

Authors:  Peter J Lee
Journal:  J Clin Monit Comput       Date:  2015-04-22       Impact factor: 2.502

6.  An easy and accurate respiratory rate monitor is necessary.

Authors:  Nicolas Marjanovic; Olivier Mimoz; Jérémy Guenezan
Journal:  J Clin Monit Comput       Date:  2019-07-24       Impact factor: 2.502

Review 7.  The Necessity of Data Mining in Clinical Emergency Medicine; A Narrative Review of the Current Literatrue.

Authors:  Elahe Parva; Reza Boostani; Zahra Ghahramani; Shahram Paydar
Journal:  Bull Emerg Trauma       Date:  2017-04

8.  Flash mob research: a single-day, multicenter, resident-directed study of respiratory rate.

Authors:  Matthew W Semler; Daniel G Stover; Andrew P Copland; Gina Hong; Michael J Johnson; Michael S Kriss; Hannah Otepka; Li Wang; Brian W Christman; Todd W Rice
Journal:  Chest       Date:  2013-06       Impact factor: 9.410

9.  Implementation of the National Early Warning Score in UK care homes: a qualitative evaluation.

Authors:  Siân Russell; Rachel Stocker; Robert Oliver Barker; Jennifer Liddle; Joy Adamson; Barbara Hanratty
Journal:  Br J Gen Pract       Date:  2020-10-29       Impact factor: 5.386

10.  Comparison of respiratory rate and peripheral oxygen saturation to assess severity in trauma patients.

Authors:  Mathieu Raux; Michel Thicoïpé; Eric Wiel; Elisabeth Rancurel; Dominique Savary; Jean-Stéphane David; Frédéric Berthier; Agnès Ricard-Hibon; Frédéric Birgel; Bruno Riou
Journal:  Intensive Care Med       Date:  2006-02-17       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.