Literature DB >> 23172656

Combination of multichannel single-voxel MRS signals using generalized least squares.

Li An1, Jan Willem van der Veen, Shizhe Li, David M Thomasson, Jun Shen.   

Abstract

PURPOSE: To propose using the generalized least square (GLS) algorithm for combining multichannel single-voxel magnetic resonance spectroscopy (MRS) signals.
MATERIALS AND METHODS: Phantom and in vivo brain MRS experiments on a 7 T scanner equipped with a 32-channel receiver coil, as well as Monte Carlo simulations, were performed to compare the coefficient of variation (CV) of the GLS method with those of two recently reported spectral combination methods.
RESULTS: Compared to the two existing methods, the GLS method significantly reduced CV values for the simulation, phantom, and in vivo experiments.
CONCLUSION: The GLS method can lead to improved precision of peak quantification.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23172656      PMCID: PMC3582859          DOI: 10.1002/jmri.23941

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  18 in total

1.  An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes.

Authors:  T Prock; D J Collins; A S K Dzik-Jurasz; M O Leach
Journal:  Phys Med Biol       Date:  2002-01-21       Impact factor: 3.609

2.  Sensitivity-encoded spectroscopic imaging.

Authors:  U Dydak; M Weiger; K P Pruessmann; D Meier; P Boesiger
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

3.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

4.  Use of phased array coils for a determination of absolute metabolite concentrations.

Authors:  Oliver Natt; Vitaliy Bezkorovaynyy; Thomas Michaelis; Jens Frahm
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

5.  Time-domain combination of MR spectroscopy data acquired using phased-array coils.

Authors:  Mark A Brown
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

6.  The rapid and automatic combination of proton MRSI data using multi-channel coils without water suppression.

Authors:  Zhengchao Dong; Bradley Peterson
Journal:  Magn Reson Imaging       Date:  2007-02-20       Impact factor: 2.546

7.  Noise correlations and SNR in phased-array MRS.

Authors:  N Martini; M F Santarelli; G Giovannetti; M Milanesi; D De Marchi; V Positano; L Landini
Journal:  NMR Biomed       Date:  2010-01       Impact factor: 4.044

Review 8.  Theory and application of array coils in MR spectroscopy.

Authors:  S M Wright; L L Wald
Journal:  NMR Biomed       Date:  1997-12       Impact factor: 4.044

9.  An NMR phased array for human cardiac 31P spectroscopy.

Authors:  C J Hardy; P A Bottomley; K W Rohling; P B Roemer
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

10.  Estimation of metabolite concentrations from localized in vivo proton NMR spectra.

Authors:  S W Provencher
Journal:  Magn Reson Med       Date:  1993-12       Impact factor: 4.668

View more
  18 in total

1.  Signal enhancement of glutamine and glutathione by single-step spectral editing.

Authors:  Li An; Maria Ferraris Araneta; Milalynn Victorino; Jun Shen
Journal:  J Magn Reson       Date:  2020-06-01       Impact factor: 2.229

Review 2.  Quantitative proton MR techniques for measuring fat.

Authors:  H H Hu; H E Kan
Journal:  NMR Biomed       Date:  2013-10-03       Impact factor: 4.044

3.  Adaptively Optimized Combination (AOC) of Phased-Array MR Spectroscopy Data in the Presence of Correlated Noise: Compared with Noise-Decorrelated or Whitened Methods.

Authors:  Minjie Wu; Liang Fang; Charles E Ray; Anand Kumar; Shaolin Yang
Journal:  Magn Reson Med       Date:  2016-11-21       Impact factor: 4.668

4.  Coil combination methods for multi-channel hyperpolarized 13C imaging data from human studies.

Authors:  Zihan Zhu; Xucheng Zhu; Michael A Ohliger; Shuyu Tang; Peng Cao; Lucas Carvajal; Adam W Autry; Yan Li; John Kurhanewicz; Susan Chang; Rahul Aggarwal; Pamela Munster; Duan Xu; Peder E Z Larson; Daniel B Vigneron; Jeremy W Gordon
Journal:  J Magn Reson       Date:  2019-02-01       Impact factor: 2.229

5.  Simultaneous measurement of glutamate, glutamine, GABA, and glutathione by spectral editing without subtraction.

Authors:  Li An; Maria Ferraris Araneta; Christopher Johnson; Jun Shen
Journal:  Magn Reson Med       Date:  2018-03-25       Impact factor: 4.668

6.  Reliability of 7T (1) H-MRS measured human prefrontal cortex glutamate, glutamine, and glutathione signals using an adapted echo time optimized PRESS sequence: A between- and within-sessions investigation.

Authors:  Níall Lally; Li An; Dipavo Banerjee; Mark J Niciu; David A Luckenbaugh; Erica M Richards; Jonathan P Roiser; Jun Shen; Carlos A Zarate; Allison C Nugent
Journal:  J Magn Reson Imaging       Date:  2015-06-07       Impact factor: 4.813

7.  Simultaneous determination of metabolite concentrations, T1 and T2 relaxation times.

Authors:  Li An; Shizhe Li; Jun Shen
Journal:  Magn Reson Med       Date:  2017-02-05       Impact factor: 4.668

8.  Phased-array combination for MR spectroscopic imaging using a water reference.

Authors:  Abas Abdoli; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2015-09-28       Impact factor: 4.668

9.  Spectral fitting using basis set modified by measured B0 field distribution.

Authors:  Ningzhi Li; Li An; Jun Shen
Journal:  NMR Biomed       Date:  2015-10-27       Impact factor: 4.044

10.  A comparison of coil combination strategies in 3D multi-channel MRSI reconstruction for patients with brain tumors.

Authors:  Maryam Vareth; Janine Lupo; Peder Larson; Sarah Nelson
Journal:  NMR Biomed       Date:  2018-08-31       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.