Literature DB >> 29575059

Simultaneous measurement of glutamate, glutamine, GABA, and glutathione by spectral editing without subtraction.

Li An1, Maria Ferraris Araneta1, Christopher Johnson1, Jun Shen1.   

Abstract

PURPOSE: To simultaneously measure glutamate, glutamine, γ-aminobutyric acid (GABA), and glutathione using spectral editing without subtraction at 7T.
METHODS: A novel spectral editing approach was proposed to simultaneously measure glutamate, glutamine, GABA, and glutathione using a TE of 56 ms at 7T. By numerical optimization of sequence timing in the presence of an editing pulse, the 4 metabolites all form relatively intense pseudo singlets with maximized peak amplitudes and minimized peak linewidths in 1 of the 3 interleaved spectra. For measuring glutamate, glutamine, and glutathione, the editing pulse targets the H3 protons of these metabolites near 2.12 parts per million. Both GABA H2 and H4 resonances are fully utilized in spectral fitting.
RESULTS: Concentration levels (/[total creatine]) of glutamate, glutamine, GABA, and glutathione from an 8 mL voxel in the pregenual anterior cingulate cortex of 5 healthy volunteers were found to be 1.26 ± 0.13, 0.33 ± 0.06, 0.13 ± 0.03, and 0.27 ± 0.03, respectively, with within-subject coefficient of variation at 3.2%, 8.2%, 7.1%, and 10.2%, respectively. The total scan time was less than 4.5 min.
CONCLUSIONS: The proposed new technique does not require data subtraction. The 3 major metabolites of the glutamatergic and GABAergic systems and the oxidative stress marker glutathione were all measured in 1 short scan with high precision. © Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

Entities:  

Keywords:  GABA; glutamate; glutamine; glutathione; multi-edit

Mesh:

Substances:

Year:  2018        PMID: 29575059      PMCID: PMC6107387          DOI: 10.1002/mrm.27172

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

Review 1.  Glutamate and glutamine: a review of in vivo MRS in the human brain.

Authors:  Saadallah Ramadan; Alexander Lin; Peter Stanwell
Journal:  NMR Biomed       Date:  2013-10-04       Impact factor: 4.044

Review 2.  Edited 1 H magnetic resonance spectroscopy in vivo: Methods and metabolites.

Authors:  Ashley D Harris; Muhammad G Saleh; Richard A E Edden
Journal:  Magn Reson Med       Date:  2017-02-02       Impact factor: 4.668

3.  Measurement error.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-09-21

4.  In vivo proton spectroscopy in presence of eddy currents.

Authors:  U Klose
Journal:  Magn Reson Med       Date:  1990-04       Impact factor: 4.668

5.  Improvement of resolution for brain coupled metabolites by optimized (1)H MRS at 7T.

Authors:  Changho Choi; Ivan E Dimitrov; Deborah Douglas; Aditya Patel; Lana G Kaiser; Carlos A Amezcua; Elizabeth A Maher
Journal:  NMR Biomed       Date:  2010-11       Impact factor: 4.044

6.  Fast computation of full density matrix of multispin systems for spatially localized in vivo magnetic resonance spectroscopy.

Authors:  Yan Zhang; Li An; Jun Shen
Journal:  Med Phys       Date:  2017-07-10       Impact factor: 4.071

7.  Measurement of glutathione in normal volunteers and stroke patients at 3T using J-difference spectroscopy with minimized subtraction errors.

Authors:  Li An; Yan Zhang; David M Thomasson; Lawrence L Latour; Eva H Baker; Jun Shen; Steven Warach
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

Review 8.  Contributions of anterior cingulate cortex to behaviour.

Authors:  O Devinsky; M J Morrell; B A Vogt
Journal:  Brain       Date:  1995-02       Impact factor: 13.501

9.  A practical guide to robust detection of GABA in human brain by J-difference spectroscopy at 3 T using a standard volume coil.

Authors:  Kevin W Waddell; Malcolm J Avison; James M Joers; John C Gore
Journal:  Magn Reson Imaging       Date:  2007-02-02       Impact factor: 2.546

10.  N-acetyl-aspartyl-glutamate detection in the human brain at 7 Tesla by echo time optimization and improved Wiener filtering.

Authors:  Li An; Shizhe Li; Emily T Wood; Daniel S Reich; Jun Shen
Journal:  Magn Reson Med       Date:  2013-11-14       Impact factor: 4.668

View more
  4 in total

1.  Signal enhancement of glutamine and glutathione by single-step spectral editing.

Authors:  Li An; Maria Ferraris Araneta; Milalynn Victorino; Jun Shen
Journal:  J Magn Reson       Date:  2020-06-01       Impact factor: 2.229

2.  Simultaneous editing of GABA and GSH with Hadamard-encoded MR spectroscopic imaging.

Authors:  Kimberly L Chan; Georg Oeltzschner; Muhammad G Saleh; Richard A E Edden; Peter B Barker
Journal:  Magn Reson Med       Date:  2019-02-22       Impact factor: 4.668

Review 3.  Glutamine Imaging: A New Avenue for Glioma Management.

Authors:  S Ekici; J A Nye; S G Neill; J W Allen; H-K Shu; C C Fleischer
Journal:  AJNR Am J Neuroradiol       Date:  2021-11-04       Impact factor: 3.825

4.  Detection of 13C labeling of glutamate and glutamine in human brain by proton magnetic resonance spectroscopy.

Authors:  Li An; Shizhe Li; Maria Ferraris Araneta; Christopher S Johnson; Jun Shen
Journal:  Sci Rep       Date:  2022-05-24       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.