Literature DB >> 23151753

Compensation for spill-in and spill-out partial volume effects in cardiac PET imaging.

Yong Du1, Igal Madar, Martin J Stumpf, Xing Rong, George S K Fung, Eric C Frey.   

Abstract

BACKGROUND: Partial volume effects (PVEs) in PET imaging result in incorrect regional activity estimates due to both spill-out and spill-in from activity in neighboring regions. It is important to compensate for both effects to achieve accurate quantification. In this study, an image-based partial volume compensation (PVC) method was developed and validated for cardiac PET. METHODS AND
RESULTS: The method uses volume-of-interest (VOI) maps segmented from contrast-enhanced CTA images to compensate for both spill-in and spill-out in each VOI. The PVC method was validated with simulation studies and also applied to images of dog cardiac perfusion PET data. The PV effects resulting from cardiac motion and myocardial uptake defects were investigated and the efficacy of the proposed PVC method in compensating for these effects was evaluated.
RESULTS: Results indicate that the magnitude and the direction of PVEs in cardiac imaging change over time. This affects the accuracy of activity distributions estimates obtained during dynamic studies. The defect regions have different PVEs as compared to the normal myocardium. Cardiac motion contributes around 10% to the PVEs. PVC effectively removed both spill-in and spill-out in cardiac imaging.
CONCLUSIONS: PVC improved left ventricular wall uniformity and quantitative accuracy. The best strategy for PVC was to compensate for the PVEs in each cardiac phase independently and treat severe uptake defects as independent regions from the normal myocardium.

Entities:  

Mesh:

Year:  2012        PMID: 23151753     DOI: 10.1007/s12350-012-9649-z

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  29 in total

Review 1.  Perfusion quantitation using positron emission tomography.

Authors:  J M Hoffman; R E Coleman
Journal:  Invest Radiol       Date:  1992-12       Impact factor: 6.016

Review 2.  Prognostic value of gated myocardial perfusion SPECT.

Authors:  Leslee J Shaw; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2004 Mar-Apr       Impact factor: 5.952

3.  Simplified quantification of Pittsburgh Compound B amyloid imaging PET studies: a comparative analysis.

Authors:  Brian J Lopresti; William E Klunk; Chester A Mathis; Jessica A Hoge; Scott K Ziolko; Xueling Lu; Carolyn C Meltzer; Kurt Schimmel; Nicholas D Tsopelas; Steven T DeKosky; Julie C Price
Journal:  J Nucl Med       Date:  2005-12       Impact factor: 10.057

4.  Partial volume effect compensation for quantitative brain SPECT imaging.

Authors:  Yong Du; Benjamin M W Tsui; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

5.  Three-dimensional correction for spillover and recovery of myocardial PET images.

Authors:  H Nuyts; A Maes; M Vrolix; C Schiepers; H Schelbert; W Kuhle; G Bormans; G Poppe; D Buxton; P Suetens; H De Geest; L Mortelmans
Journal:  J Nucl Med       Date:  1996-05       Impact factor: 10.057

6.  Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging.

Authors:  G D Hutchins; M Schwaiger; K C Rosenspire; J Krivokapich; H Schelbert; D E Kuhl
Journal:  J Am Coll Cardiol       Date:  1990-04       Impact factor: 24.094

7.  Characterization of uptake of the new PET imaging compound 18F-fluorobenzyl triphenyl phosphonium in dog myocardium.

Authors:  Igal Madar; Hayden T Ravert; Yong Du; John Hilton; Lana Volokh; Robert F Dannals; James J Frost; Joshua M Hare
Journal:  J Nucl Med       Date:  2006-08       Impact factor: 10.057

8.  Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans.

Authors:  P Chareonthaitawee; P A Kaufmann; O Rimoldi; P G Camici
Journal:  Cardiovasc Res       Date:  2001-04       Impact factor: 10.787

Review 9.  Assessment of myocardial viability.

Authors:  Mark I Travin; Steven R Bergmann
Journal:  Semin Nucl Med       Date:  2005-01       Impact factor: 4.446

10.  Assessment of severity of coronary artery stenosis in a canine model using the PET agent 18F-fluorobenzyl triphenyl phosphonium: comparison with 99mTc-tetrofosmin.

Authors:  Igal Madar; Hayden Ravert; Antony Dipaula; Yong Du; Robert F Dannals; Lewis Becker
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

View more
  6 in total

1.  Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

Authors:  Esther M Vicente; Martin A Lodge; Steven P Rowe; Richard L Wahl; Eric C Frey
Journal:  Med Phys       Date:  2017-03-28       Impact factor: 4.071

2.  Can Parameters Other than Minimal Axial Diameter in MRI and PET/CT Further Improve Diagnostic Accuracy for Equivocal Retropharyngeal Lymph Nodes in Nasopharyngeal Carcinoma?

Authors:  Yu-Wen Wang; Chin-Shun Wu; Guo-Yi Zhang; Chih-Han Chang; Kuo-Sheng Cheng; Wei-Jen Yao; Yu-Kang Chang; Tsair-Wei Chien; Li-Ching Lin; Keng-Ren Lin
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

3.  Validation of the physiological background correction method for the suppression of the spill-in effect near highly radioactive regions in positron emission tomography.

Authors:  Mercy I Akerele; Palak Wadhwa; Jesus Silva-Rodriguez; William Hallett; Charalampos Tsoumpas
Journal:  EJNMMI Phys       Date:  2018-12-05

4.  Does the beta regularization parameter of bayesian penalized likelihood reconstruction always affect the quantification accuracy and image quality of positron emission tomography computed tomography?

Authors:  Zhifang Wu; Binwei Guo; Bin Huang; Bin Zhao; Zhixing Qin; Xinzhong Hao; Meng Liang; Jun Xie; Sijin Li
Journal:  J Appl Clin Med Phys       Date:  2021-03-08       Impact factor: 2.102

5.  Quantitative evaluation of PSMA PET imaging using a realistic anthropomorphic phantom and shell-less radioactive epoxy lesions.

Authors:  Roberto Fedrigo; Dan J Kadrmas; Patricia E Edem; Lauren Fougner; Ivan S Klyuzhin; M Peter Petric; François Bénard; Arman Rahmim; Carlos Uribe
Journal:  EJNMMI Phys       Date:  2022-01-15

6.  Accuracy Assessment of SUV Measurements in SPECT/CT: A Phantom Study.

Authors:  Fatin Halim; Hizwan Yahya; Khairul Nizam Jaafar; Syahir Mansor
Journal:  J Nucl Med Technol       Date:  2021-03-15
  6 in total