Literature DB >> 23149875

The association between difficulty using positive airway pressure equipment and adherence to therapy: a pilot study.

Constance H Fung1, Jennifer L Martin, Uyi Igodan, Stella Jouldjian, Cathy Alessi.   

Abstract

PURPOSE: Little is known about the ease of use of positive airway pressure (PAP) equipment and whether PAP equipment usability is associated with adherence. This pilot project aims to determine whether perceived difficulty with the mechanics of using PAP equipment is associated with nonadherence.
METHODS: Within a larger study of insomnia treatments, we screened (via telephone interview) 148 adults for sleep apnea/prior PAP use and asked them to describe the degree of difficulty putting on their PAP mask, adjusting their mask straps, turning dials/pushing PAP machine buttons, disconnecting tubing, and removing the machine's water chamber (five items; five-point Likert-like scale) and to report their PAP use (0 versus ≥1 days in the past week).
RESULTS: Mean age of participants was 66.7 years (SD 7.0). Thirty respondents (20.3 %) reported at least "some difficulty" with at least one aspect of PAP equipment usability, and 15 respondents (10.1 %) reported at least "quite a lot of difficulty" with one or more aspects of PAP equipment usability. Of the participants, 43.9 % reported not using PAP equipment at all during the past week. Participants (73.3 %) with substantial PAP equipment difficulty (at least quite a lot of difficulty) versus 40.6 % without substantial difficulty reported zero nights of PAP use in the past week (chi-square 5.86, p = .015).
CONCLUSIONS: Difficulty using PAP equipment is associated with PAP nonadherence. Studies are needed to confirm these findings and to identify determinants of poor usability. If findings are confirmed, strategies could be developed to improve PAP usability, which may improve adherence.

Entities:  

Mesh:

Year:  2012        PMID: 23149875     DOI: 10.1007/s11325-012-0779-y

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  22 in total

Review 1.  A framework for the conceptual modelling of assistive technology device outcomes.

Authors:  M J Fuhrer; J W Jutai; M J Scherer; F DeRuyter
Journal:  Disabil Rehabil       Date:  2003-11-18       Impact factor: 3.033

2.  Factors associated with undiagnosed obstructive sleep apnoea in hypertensive primary care patients.

Authors:  Anders Broström; Ola Sunnergren; Kristofer Årestedt; Peter Johansson; Martin Ulander; Barbara Riegel; Eva Svanborg
Journal:  Scand J Prim Health Care       Date:  2012-06       Impact factor: 2.581

Review 3.  A systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions.

Authors:  Amy M Sawyer; Nalaka S Gooneratne; Carole L Marcus; Dafna Ofer; Kathy C Richards; Terri E Weaver
Journal:  Sleep Med Rev       Date:  2011-06-08       Impact factor: 11.609

4.  The association of sleep-disordered breathing and sleep symptoms with quality of life in the Sleep Heart Health Study.

Authors:  C M Baldwin; K A Griffith; F J Nieto; G T O'Connor; J A Walsleben; S Redline
Journal:  Sleep       Date:  2001-02-01       Impact factor: 5.849

5.  Perspectives of patients with disabilities on the accessibility of medical equipment: examination tables, imaging equipment, medical chairs, and weight scales.

Authors:  Molly Follette Story; Erin Schwier; June Isaacson Kailes
Journal:  Disabil Health J       Date:  2009-10       Impact factor: 2.554

6.  Determinants of continuous positive airway pressure adherence in a sleep clinic cohort of South Florida Hispanic veterans.

Authors:  D M Wallace; S S Vargas; S J Schwartz; M S Aloia; S Shafazand
Journal:  Sleep Breath       Date:  2012-04-17       Impact factor: 2.816

7.  Patient preferences and experiences of CPAP and oral appliances for the treatment of obstructive sleep apnea: a qualitative analysis.

Authors:  Fernanda R Almeida; Natalie Henrich; Carlo Marra; Larry D Lynd; Alan A Lowe; Hiroko Tsuda; John A Fleetham; Benjamin Pliska; Najib Ayas
Journal:  Sleep Breath       Date:  2012-07-26       Impact factor: 2.816

8.  The predictive value of self assessed general, physical, and mental health on functional decline and mortality in older adults.

Authors:  Y Lee
Journal:  J Epidemiol Community Health       Date:  2000-02       Impact factor: 3.710

9.  Side effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers.

Authors:  J L Pépin; P Leger; D Veale; B Langevin; D Robert; P Lévy
Journal:  Chest       Date:  1995-02       Impact factor: 9.410

10.  Reducing motor-vehicle collisions, costs, and fatalities by treating obstructive sleep apnea syndrome.

Authors:  Alex Sassani; Larry J Findley; Meir Kryger; Eric Goldlust; Charles George; Terence M Davidson
Journal:  Sleep       Date:  2004-05-01       Impact factor: 5.849

View more
  3 in total

1.  Human factors/usability barriers to home medical devices among individuals with disabling conditions: in-depth interviews with positive airway pressure device users.

Authors:  Constance H Fung; Uyi Igodan; Cathy Alessi; Jennifer L Martin; Joseph M Dzierzewski; Karen Josephson; B Josea Kramer
Journal:  Disabil Health J       Date:  2014-07-01       Impact factor: 2.554

2.  Development of the Usability of Sleep Apnea Equipment-Positive Airway Pressure (USE-PAP) questionnaire.

Authors:  Constance H Fung; Jennifer L Martin; Ron D Hays; Juan Carlos Rodriguez; Uyi Igodan; Stella Jouldjian; Joseph M Dzierzewski; B Josea Kramer; Karen Josephson; Cathy Alessi
Journal:  Sleep Med       Date:  2015-02-12       Impact factor: 3.492

3.  Patient-Reported Usability of Positive Airway Pressure Equipment Is Associated With Adherence in Older Adults.

Authors:  Constance H Fung; Jennifer L Martin; Ron D Hays; Emily S Patterson; Ravi Aysola; Nananda Col; Michael N Mitchell; Cindy Truong; Joseph M Dzierzewski; Stella Jouldjian; Yeonsu Song; Juan Carlos Rodriguez; Karen Josephson; Cathy Alessi
Journal:  Sleep       Date:  2017-03-01       Impact factor: 5.849

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.