Literature DB >> 23124585

Aortic pulse wave velocity measurements with undersampled 4D flow-sensitive MRI: comparison with 2D and algorithm determination.

Andrew L Wentland1, Oliver Wieben, Chris J François, Christina Boncyk, Alejandro Munoz Del Rio, Kevin M Johnson, Thomas M Grist, Alex Frydrychowicz.   

Abstract

PURPOSE: To compare pulse wave velocity (PWV) measurements obtained from radially undersampled 4D phase-contrast magnetic resonance imaging (PC-MRI) with 2D PC measurements and to evaluate four PWV algorithms.
MATERIALS AND METHODS: PWV was computed from radially undersampled 3D, 3-directionally velocity-encoded PC-MRI (4D) acquisitions performed on a 3T MR scanner in 18 volunteers. High temporal resolution 2D PC scans serving as a reference standard were available in 14 volunteers. Four PWV algorithms were tested: time-to-upstroke (TTU), time-to-peak (TTP), time-to-foot (TTF), and cross-correlation (XCorr). Bland-Altman analysis was used to determine inter- and intraobserver reproducibility and to compare differences between algorithms. Differences in age and PWV measurements were analyzed with Student's t-tests. The variability of age-corrected data was assessed with a Brown-Forsythe analysis of variance (ANOVA) test.
RESULTS: 2D (4.6-5.3 m/s) and 4D (3.8-4.8 m/s) PWV results were in agreement with previously reported values in healthy subjects. Of the four PWV algorithms, the TTU, TTF, and XCorr algorithms gave similar and reliable results. Average biases of +0.30 m/s and -0.01 m/s were determined for intra- and interobserver variability, respectively. The Brown-Forsythe test revealed that no differences in variability could be found between 2D and 4D PWV measurements.
CONCLUSION: 4D PC-MRI with radial undersampling provides reliable and reproducible measurements of PWV. TTU, TTF, and XCorr were the preferred PWV algorithms.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23124585      PMCID: PMC3566322          DOI: 10.1002/jmri.23877

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  26 in total

1.  Undersampled projection reconstruction applied to MR angiography.

Authors:  D C Peters; F R Korosec; T M Grist; W F Block; J E Holden; K K Vigen; C A Mistretta
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  In vitro validation of MR measurements of arterial pulse-wave velocity in the presence of reflected waves.

Authors:  M Stevanov; J Baruthio; D Gounot; D Grucker
Journal:  J Magn Reson Imaging       Date:  2001-08       Impact factor: 4.813

3.  Age-associated changes in regional aortic pulse wave velocity.

Authors:  W J Rogers; Y L Hu; D Coast; D A Vido; C M Kramer; R E Pyeritz; N Reichek
Journal:  J Am Coll Cardiol       Date:  2001-10       Impact factor: 24.094

4.  Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction.

Authors:  Jiang Du; Timothy J Carroll; Ethan Brodsky; Aiming Lu; T M Grist; Charles A Mistretta; Walter F Block
Journal:  J Magn Reson Imaging       Date:  2004-11       Impact factor: 4.813

5.  Aortic stiffness is an independent predictor of fatal stroke in essential hypertension.

Authors:  Stéphane Laurent; Sandrine Katsahian; Céline Fassot; Anne-Isabelle Tropeano; Isabelle Gautier; Brigitte Laloux; Pierre Boutouyrie
Journal:  Stroke       Date:  2003-04-03       Impact factor: 7.914

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Age-related changes of human aortic flow wave velocity measured noninvasively by magnetic resonance imaging.

Authors:  R H Mohiaddin; D N Firmin; D B Longmore
Journal:  J Appl Physiol (1985)       Date:  1993-01

8.  Pulsewave velocity measurement using a new real-time MR-method.

Authors:  M Bock; L R Schad; E Müller; W J Lorenz
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

9.  Estimation of global aortic pulse wave velocity by flow-sensitive 4D MRI.

Authors:  Michael Markl; Wolf Wallis; Stefanie Brendecke; Jan Simon; Alex Frydrychowicz; Andreas Harloff
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

10.  Time-resolved three-dimensional phase-contrast MRI.

Authors:  Michael Markl; Frandics P Chan; Marcus T Alley; Kris L Wedding; Mary T Draney; Chris J Elkins; David W Parker; Ryan Wicker; Charles A Taylor; Robert J Herfkens; Norbert J Pelc
Journal:  J Magn Reson Imaging       Date:  2003-04       Impact factor: 4.813

View more
  24 in total

1.  In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation.

Authors:  Timothy Ruesink; Rafael Medero; David Rutkowski; Alejandro Roldán-Alzate
Journal:  Cardiovasc Eng Technol       Date:  2018-09-14       Impact factor: 2.495

Review 2.  Imaging Insights on the Aorta in Aging.

Authors:  Yoshiaki Ohyama; Alban Redheuil; Nadjia Kachenoura; Bharath Ambale Venkatesh; Joao A C Lima
Journal:  Circ Cardiovasc Imaging       Date:  2018-04       Impact factor: 7.792

3.  Automatic correction of background phase offset in 4D-flow of great vessels and of the heart in MRI using a third-order surface model.

Authors:  Damian Craiem; Ariel F Pascaner; Mariano E Casciaro; Umit Gencer; Joaquin Alcibar; Gilles Soulat; Elie Mousseaux
Journal:  MAGMA       Date:  2019-06-22       Impact factor: 2.310

Review 4.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

Review 5.  Clinical Applications of MRA 4D-Flow.

Authors:  Lilia M Sierra-Galan; Christopher J François
Journal:  Curr Treat Options Cardiovasc Med       Date:  2019-09-10

6.  k-t GRAPPA accelerated four-dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress.

Authors:  Susanne Schnell; Michael Markl; Pegah Entezari; Riti J Mahadewia; Edouard Semaan; Zoran Stankovic; Jeremy Collins; James Carr; Bernd Jung
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

7.  Measurements of wall shear stress and aortic pulse wave velocity in swine with familial hypercholesterolemia.

Authors:  Andrew L Wentland; Oliver Wieben; Dhanansayan Shanmuganayagam; Christian G Krueger; Jennifer J Meudt; Daniel Consigny; Leonardo Rivera; Patrick E McBride; Jess D Reed; Thomas M Grist
Journal:  J Magn Reson Imaging       Date:  2014-06-25       Impact factor: 4.813

Review 8.  Advanced flow MRI: emerging techniques and applications.

Authors:  M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby
Journal:  Clin Radiol       Date:  2016-03-02       Impact factor: 2.350

Review 9.  Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness.

Authors:  Andrew L Wentland; Thomas M Grist; Oliver Wieben
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

10.  Assessment of vascular stiffness in the internal carotid artery proximal to the carotid canal in Alzheimer's disease using pulse wave velocity from low rank reconstructed 4D flow MRI.

Authors:  Leonardo A Rivera-Rivera; Karly A Cody; Laura Eisenmenger; Paul Cary; Howard A Rowley; Cynthia M Carlsson; Sterling C Johnson; Kevin M Johnson
Journal:  J Cereb Blood Flow Metab       Date:  2020-03-13       Impact factor: 6.200

View more