Literature DB >> 20512861

Estimation of global aortic pulse wave velocity by flow-sensitive 4D MRI.

Michael Markl1, Wolf Wallis, Stefanie Brendecke, Jan Simon, Alex Frydrychowicz, Andreas Harloff.   

Abstract

The aim of this study was to determine the value of flow-sensitive four-dimensional MRI for the assessment of pulse wave velocity as a measure of vessel compliance in the thoracic aorta. Findings in 12 young healthy volunteers were compared with those in 25 stroke patients with aortic atherosclerosis and an age-matched normal control group (n = 9). Results from pulse wave velocity calculations incorporated velocity data from the entire aorta and were compared to those of standard methods based on flow waveforms at only two specific anatomic landmarks. Global aortic pulse wave velocity was higher in patients with atherosclerosis (7.03 +/- 0.24 m/sec) compared to age-matched controls (6.40 +/- 0.32 m/sec). Both were significantly (P < 0.001) increased compared to younger volunteers (4.39 +/- 0.32 m/sec). Global aortic pulse wave velocity in young volunteers was in good agreement with previously reported MRI studies and catheter measurements. Estimation of measurement inaccuracies and error propagation analysis demonstrated only minor uncertainties in measured flow waveforms and moderate relative errors below 16% for aortic compliance in all 46 subjects. These results demonstrate the feasibility of pulse wave velocity calculation based on four-dimensional MRI data by exploiting its full volumetric coverage, which may also be an advantage over standard two-dimensional techniques in the often-distorted route of the aorta in patients with atherosclerosis. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20512861     DOI: 10.1002/mrm.22353

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  41 in total

Review 1.  Intracardiac flow visualization: current status and future directions.

Authors:  Daniel Rodriguez Muñoz; Michael Markl; José Luis Moya Mur; Alex Barker; Covadonga Fernández-Golfín; Patrizio Lancellotti; José Luis Zamorano Gómez
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-08-01       Impact factor: 6.875

2.  In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation.

Authors:  Timothy Ruesink; Rafael Medero; David Rutkowski; Alejandro Roldán-Alzate
Journal:  Cardiovasc Eng Technol       Date:  2018-09-14       Impact factor: 2.495

Review 3.  Imaging Insights on the Aorta in Aging.

Authors:  Yoshiaki Ohyama; Alban Redheuil; Nadjia Kachenoura; Bharath Ambale Venkatesh; Joao A C Lima
Journal:  Circ Cardiovasc Imaging       Date:  2018-04       Impact factor: 7.792

4.  Age-related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve disease.

Authors:  Pim van Ooij; Julio Garcia; Wouter V Potters; S Chris Malaisrie; Jeremy D Collins; James C Carr; Michael Markl; Alex J Barker
Journal:  J Magn Reson Imaging       Date:  2015-10-19       Impact factor: 4.813

Review 5.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

6.  Pediatric heterozygous familial hypercholesterolemia patients have locally increased aortic pulse wave velocity and wall thickness at the aortic root.

Authors:  Andrew Tran; Barbara Burkhardt; Animesh Tandon; Sarah Blumenschein; Arna van Engelen; Marina Cecelja; Song Zhang; Sergio Uribe; Joaquin Mura; Gerald Greil; Tarique Hussain
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-17       Impact factor: 2.357

Review 7.  Noninvasive Imaging of Flow and Vascular Function in Disease of the Aorta.

Authors:  Matthew C Whitlock; W Gregory Hundley
Journal:  JACC Cardiovasc Imaging       Date:  2015-09

8.  AORTIC PULSE WAVE VELOCITY MEASURED BY PULSE WAVE IMAGING (PWI): A COMPARISON WITH APPLANATION TONOMETRY.

Authors:  Jonathan Vappou; Jianwen Luo; Kazue Okajima; Marco Di Tullio; Elisa Konofagou
Journal:  Artery Res       Date:  2011-06-01       Impact factor: 0.597

Review 9.  Challenges of cardiac image analysis in large-scale population-based studies.

Authors:  Pau Medrano-Gracia; Brett R Cowan; Avan Suinesiaputra; Alistair A Young
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

10.  Measurements of wall shear stress and aortic pulse wave velocity in swine with familial hypercholesterolemia.

Authors:  Andrew L Wentland; Oliver Wieben; Dhanansayan Shanmuganayagam; Christian G Krueger; Jennifer J Meudt; Daniel Consigny; Leonardo Rivera; Patrick E McBride; Jess D Reed; Thomas M Grist
Journal:  J Magn Reson Imaging       Date:  2014-06-25       Impact factor: 4.813

View more