Literature DB >> 23118570

Radiation dose reduction of chest CT with iterative reconstruction in image space - Part II: assessment of radiologists' preferences using dual source CT.

Hye Jeon Hwang1, Joon Beom Seo, Jin Seong Lee, Jae-Woo Song, Song Soo Kim, Hyun Joo Lee, Chae Hun Lim.   

Abstract

OBJECTIVE: To evaluate the impact of radiation dose and reconstruction algorithms on radiologists' preferences, and whether an iterative reconstruction in image space (IRIS) can be used for dose reduction in chest CT.
MATERIALS AND METHODS: Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying the dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from one tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Ten H-IRIS/F-IRIS, 10 H-FBP/H-IRIS, 40 F-FBP/F-IRIS and 40 F-FBP/H-IRIS pairs of each SDCT and LDCT were randomized. The preference for clinical usage was determined by two radiologists with a 5-point-scale system for the followings: noise, contrast, and sharpness of mediastinum and lung.
RESULTS: Radiologists preferred IRIS over FBP images in the same radiation dose for the evaluation of the lungs in both SDCT (p = 0.035) and LDCT (p < 0.001). When comparing between H-IRIS and F-IRIS, decreased radiation resulted in decreased preference. Observers preferred H-IRIS over F-FBP for the lungs in both SDCT and LDCT, even with reduced radiation dose by half in IRIS image (p < 0.05).
CONCLUSION: Radiologists' preference may be influenced by both radiation dose and reconstruction algorithm. According to our preliminary results, dose reduction at 50% with IRIS may be feasible for lung parenchymal evaluation.

Entities:  

Keywords:  Chest CT; Iterative reconstruction in image space; Preference; Radiation dose reduction

Mesh:

Substances:

Year:  2012        PMID: 23118570      PMCID: PMC3484292          DOI: 10.3348/kjr.2012.13.6.720

Source DB:  PubMed          Journal:  Korean J Radiol        ISSN: 1229-6929            Impact factor:   3.500


  18 in total

1.  Pulmonary nodules: experimental and clinical studies at low-dose CT.

Authors:  S Diederich; H Lenzen; R Windmann; Z Puskas; T M Yelbuz; S Henneken; T Klaiber; M Eameri; N Roos; P E Peters
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

Review 2.  AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT.

Authors:  Michael F McNitt-Gray
Journal:  Radiographics       Date:  2002 Nov-Dec       Impact factor: 5.333

3.  Dose reduction in CT: how low can we go?

Authors:  Lee F Rogers
Journal:  AJR Am J Roentgenol       Date:  2002-08       Impact factor: 3.959

4.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients.

Authors:  François Pontana; Alain Duhamel; Julien Pagniez; Thomas Flohr; Jean-Baptiste Faivre; Anne-Lise Hachulla; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2010-11-16       Impact factor: 5.315

5.  Individually adapted examination protocols for reduction of radiation exposure in chest CT.

Authors:  J E Wildberger; A H Mahnken; T Schmitz-Rode; T Flohr; A Stargardt; P Haage; S Schaller; R W Günther
Journal:  Invest Radiol       Date:  2001-10       Impact factor: 6.016

6.  Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions.

Authors:  H Greess; H Wolf; U Baum; M Lell; M Pirkl; W Kalender; W A Bautz
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

7.  Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers.

Authors:  Stefan Diederich; Dag Wormanns; Michael Semik; Michael Thomas; Horst Lenzen; Nikolaus Roos; Walter Heindel
Journal:  Radiology       Date:  2002-03       Impact factor: 11.105

8.  High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography.

Authors:  Michael M Lell; Matthias May; Paul Deak; Sedat Alibek; Michael Kuefner; Axel Kuettner; Henrik Köhler; Stephan Achenbach; Michael Uder; Tanja Radkow
Journal:  Invest Radiol       Date:  2011-02       Impact factor: 6.016

9.  Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality.

Authors:  J Lucaya; J Piqueras; P García-Peña; G Enríquez; M García-Macías; J Sotil
Journal:  AJR Am J Roentgenol       Date:  2000-10       Impact factor: 3.959

10.  Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT.

Authors:  Hye Jeon Hwang; Joon Beom Seo; Jin Seong Lee; Jae-Woo Song; Song Soo Kim; Hyun Joo Lee; Chae Hun Lim
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

View more
  4 in total

1.  Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) improves chest CT image quality and reduces radiation exposure.

Authors:  Tsuneo Yamashiro; Tetsuhiro Miyara; Osamu Honda; Hisashi Kamiya; Kiyoshi Murata; Yoshiharu Ohno; Noriyuki Tomiyama; Hiroshi Moriya; Mitsuhiro Koyama; Satoshi Noma; Ayano Kamiya; Yuko Tanaka; Sadayuki Murayama
Journal:  PLoS One       Date:  2014-08-25       Impact factor: 3.240

2.  Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT.

Authors:  Hye Jeon Hwang; Joon Beom Seo; Jin Seong Lee; Jae-Woo Song; Song Soo Kim; Hyun Joo Lee; Chae Hun Lim
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

3.  Adaptive iterative dose reduction algorithm in CT: effect on image quality compared with filtered back projection in body phantoms of different sizes.

Authors:  Milim Kim; Jeong Min Lee; Jeong Hee Yoon; Hyoshin Son; Jin Woo Choi; Joon Koo Han; Byung Ihn Choi
Journal:  Korean J Radiol       Date:  2014-03-07       Impact factor: 3.500

4.  Radiation dose reduction via sinogram affirmed iterative reconstruction and automatic tube voltage modulation (CARE kV) in abdominal CT.

Authors:  Hyun Joo Shin; Yong Eun Chung; Young Han Lee; Jin-Young Choi; Mi-Suk Park; Myeong-Jin Kim; Ki Whang Kim
Journal:  Korean J Radiol       Date:  2013-11-05       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.