Influence of blood specimen collection method on various preanalytical sample quality indicators.

Tester F Ashavaid1, Sucheta P Dandekar, Bhamini Keny, Vishaal R Bhambhwani.   

Abstract

Preanalytical errors contribute to a large proportion of total laboratory errors. In order to achieve continuous laboratory improvement, it is important to focus on all phases of patient specimen testing i.e. preanalytical, analytical and post-analytical. With large variations in the way venous blood specimens are collected using diverse devices in the country, the effect of such practices on specimen quality is not known. The purpose of this study was to monitor fourteen specimen preanalytical quality indicators in order to compare the usage of evacuated blood collection devices with needle and syringe open collection using either disposable tubes or re-washed glass vials. The study involved 26638 patient specimens assessed over a period of 6 months. The results demonstrated that evacuated closed blood collection resulted in an approximate 100-fold reduction in the incidence of hemolysis in samples. Similarly, there was a 200-fold reduction in incidence of insufficient specimen quantity while using evacuated collection system. It was also found that incidence of specimen contamination, improper volume of sample collected, and specimen spillage was also lower when the evacuated collection system was used. Further, it was also observed that the facility with a laboratory information system demonstrated much lower specimen identification and related errors. The observed results clearly demonstrate that the usage of the evacuated blood collection system resulted in improvement of preanalytical specimen quality as compared to needle and syringe usage.

Entities:  

Keywords:  Hemolysis; Needle and Syringe; Open collection; Preanalytical; Total quality; Vacutainer

Year:  2008        PMID: 23105740      PMCID: PMC3453073          DOI: 10.1007/s12291-008-0032-4

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  8 in total

1.  Prolonged prothrombin time and activated partial thromboplastin time due to underfilled specimen tubes with 109 mmol/L (3.2%) citrate anticoagulant.

Authors:  J Reneke; J Etzell; S Leslie; V L Ng; E L Gottfried
Journal:  Am J Clin Pathol       Date:  1998-06       Impact factor: 2.493

2.  [Standardisation of obtaining blood samples: influence of tourniquet application on 33 constituents of blood and serum (author's transl)].

Authors:  B Junge; H Hoffmeister; H M Feddersen; L Röcker
Journal:  Dtsch Med Wochenschr       Date:  1978-02-10       Impact factor: 0.628

3.  Mistakes in a stat laboratory: types and frequency.

Authors:  M Plebani; P Carraro
Journal:  Clin Chem       Date:  1997-08       Impact factor: 8.327

4.  Pseudohyperkalemia caused by fist clenching during phlebotomy.

Authors:  B R Don; A Sebastian; M Cheitlin; M Christiansen; M Schambelan
Journal:  N Engl J Med       Date:  1990-05-03       Impact factor: 91.245

5.  Recommended "order of draw" for collecting blood specimens into additive-containing tubes.

Authors:  R R Calam; M H Cooper
Journal:  Clin Chem       Date:  1982-06       Impact factor: 8.327

6.  The effects of inaccurate blood sample volume on prothrombin time (PT) and activated partial thromboplastin time (aPTT).

Authors:  P Peterson; E L Gottfried
Journal:  Thromb Haemost       Date:  1982-04-30       Impact factor: 5.249

Review 7.  Putting bar codes to work for improved patient care.

Authors:  M Weilert; L L Tilzer
Journal:  Clin Lab Med       Date:  1991-03       Impact factor: 1.935

8.  Transfusion medicine monitoring practices. A study of the College of American Pathologists/Centers for Disease Control and Prevention Outcomes Working Group.

Authors:  D J Boone; S D Steindel; R Herron; P J Howanitz; P Bachner; F Meier; R B Schifman; R B Zarbo
Journal:  Arch Pathol Lab Med       Date:  1995-11       Impact factor: 5.534

  8 in total
  2 in total

1.  Influence of method of specimen collection on various preanalytical sample quality indicators in EDTA blood collected for cell counting.

Authors:  Tester F Ashavaid; Sucheta P Dandekar; S Khodaiji; M H Ansari; Adarsh Pal Singh
Journal:  Indian J Clin Biochem       Date:  2009-12-30

2.  Identification of Pre-examination Errors in the Chemical Pathology Laboratory at the University Hospital of the West Indies.

Authors:  Lowell L Dilworth; Donovan A McGrowder; Rory K Thompson
Journal:  Indian J Clin Biochem       Date:  2013-05-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.