Literature DB >> 23105860

Influence of method of specimen collection on various preanalytical sample quality indicators in EDTA blood collected for cell counting.

Tester F Ashavaid1, Sucheta P Dandekar, S Khodaiji, M H Ansari, Adarsh Pal Singh.   

Abstract

Improving specimen quality as well as healthcare worker (HCW) safety poses significant concerns for today's laboratories. With an increasing number of diagnostic tests requested, laboratory professionals are faced with challenges to reduce laboratory errors, improve the quality of laboratory results to assure accurate diagnosis and implement initiatives to ensure healthcare worker safety and minimize risk of exposure to bloodborne pathogens. A prior study conducted in 2008 reported that variations in blood collection methods for clinical chemistry assays may affect overall specimen quality. As a follow up, the current study assessed the quality of 22563 patient specimens for cell counting in EDTA blood collection tubes that were obtained with needle and syringe collection (open) using either disposable tubes or re-washed glass vials or with an evacuated blood collection system (closed). Based on the observations, the use of the evacuated blood collection system resulted in better preanalytical specimen quality as compared with needle and syringe collection. The findings also showed an approximately 70-fold reduction in the incidence of clotting as well as fewer instrument-generated flags using the evacuated collection system. In addition, the use of an evacuated collection system for venous blood collection demonstrated lesser chance of blood exposure to healthcare workers.

Entities:  

Keywords:  EDTA blood collection; Evacuated collection; Preanalytical; Sample quality

Year:  2009        PMID: 23105860      PMCID: PMC3453063          DOI: 10.1007/s12291-009-0064-4

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  10 in total

Review 1.  Errors in laboratory medicine.

Authors:  Pierangelo Bonini; Mario Plebani; Ferruccio Ceriotti; Francesca Rubboli
Journal:  Clin Chem       Date:  2002-05       Impact factor: 8.327

Review 2.  Quality indicators and specifications for the extra-analytical phases in clinical laboratory management.

Authors:  Carmen Ricós; Montserrat García-Victoria; Blanca de la Fuente
Journal:  Clin Chem Lab Med       Date:  2004       Impact factor: 3.694

3.  Preanalytic error tracking in a laboratory medicine department: results of a 1-year experience.

Authors:  Giuseppe Lippi; Antonella Bassi; Giorgio Brocco; Martina Montagnana; Gian Luca Salvagno; Gian Cesare Guidi
Journal:  Clin Chem       Date:  2006-07       Impact factor: 8.327

4.  Errors in a stat laboratory: types and frequencies 10 years later.

Authors:  Paolo Carraro; Mario Plebani
Journal:  Clin Chem       Date:  2007-05-24       Impact factor: 8.327

5.  Specimen collection and handling: standardization of blood sample collection.

Authors:  Harald Tammen
Journal:  Methods Mol Biol       Date:  2008

Review 6.  Quality improvement in laboratory medicine: extra-analytical issues.

Authors:  Giuseppe Lippi; Roberto Fostini; Gian Cesare Guidi
Journal:  Clin Lab Med       Date:  2008-06       Impact factor: 1.935

7.  Mistakes in a stat laboratory: types and frequency.

Authors:  M Plebani; P Carraro
Journal:  Clin Chem       Date:  1997-08       Impact factor: 8.327

8.  Influence of blood specimen collection method on various preanalytical sample quality indicators.

Authors:  Tester F Ashavaid; Sucheta P Dandekar; Bhamini Keny; Vishaal R Bhambhwani
Journal:  Indian J Clin Biochem       Date:  2008-06-11

9.  Errors, mistakes, blunders, outliers, or unacceptable results: how many?

Authors:  D L Witte; S A VanNess; D S Angstadt; B J Pennell
Journal:  Clin Chem       Date:  1997-08       Impact factor: 8.327

10.  Preanalytical quality control program - an overview of results (2001-2005 summary).

Authors:  Ma Jesús Alsina; Virtudes Alvarez; Núria Barba; Sandra Bullich; Mariano Cortés; Irene Escoda; Cecília Martínez-Brú
Journal:  Clin Chem Lab Med       Date:  2008       Impact factor: 3.694

  10 in total
  3 in total

1.  Types and frequency of preanalytical errors in haematology lab.

Authors:  Shashi Upreti; Sanjay Upreti; Rani Bansal; Nadia Jeelani; Vinay Bharat
Journal:  J Clin Diagn Res       Date:  2013-11-10

2.  Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.

Authors:  Vikram Narang HarsimranKaur; Pavneet Kaur Selhi; Neena Sood; Aminder Singh
Journal:  Iran J Pathol       Date:  2016

3.  Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India.

Authors:  Pitchaikaran Arul; Magesh Pushparaj; Kanmani Pandian; Lingasamy Chennimalai; Karthika Rajendran; Eniya Selvaraj; Suresh Masilamani
Journal:  J Lab Physicians       Date:  2018 Apr-Jun
  3 in total