Literature DB >> 20527548

Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy.

O A Zeidan1, S I Sriprisan, O Lopatiuk-Tirpak, P A Kupelian, S L Meeks, W C Hsi, Z Li, J R Palta, M J Maryanski.   

Abstract

PURPOSE: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry.
METHODS: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria.
RESULTS: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (> 97%) of the gel dose maps pass the 3%/3 mm gamma criterion.
CONCLUSIONS: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20527548     DOI: 10.1118/1.3388869

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Determination of the depth dose distribution of proton beam using PRESAGE™ dosimeter.

Authors:  L Zhao; I J Das; Q Zhao; A Thomas; J Adamovics; M Oldman
Journal:  J Phys Conf Ser       Date:  2010

2.  Dosimetric verification for intensity-modulated arc therapy plans by use of 2D diode array, radiochromic film and radiosensitive polymer gel.

Authors:  Naoki Hayashi; Ryan L Malmin; Yoichi Watanabe
Journal:  J Radiat Res       Date:  2014-01-20       Impact factor: 2.724

3.  3D reconstruction of scintillation light emission from proton pencil beams using limited viewing angles-a simulation study.

Authors:  CheukKai Hui; Daniel Robertson; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-07-23       Impact factor: 3.609

4.  Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields.

Authors:  Li Zhao; Joseph Newton; Mark Oldham; Indra J Das; Chee-Wai Cheng; John Adamovics
Journal:  Phys Med Biol       Date:  2012-10-26       Impact factor: 3.609

5.  Three-dimensional dosimetry of TomoTherapy by MRI-based polymer gel technique.

Authors:  Yoichi Watanabe; N Gopishankar
Journal:  J Appl Clin Med Phys       Date:  2010-09-14       Impact factor: 2.102

Review 6.  Towards effective and efficient patient-specific quality assurance for spot scanning proton therapy.

Authors:  X Ronald Zhu; Yupeng Li; Dennis Mackin; Heng Li; Falk Poenisch; Andrew K Lee; Anita Mahajan; Steven J Frank; Michael T Gillin; Narayan Sahoo; Xiaodong Zhang
Journal:  Cancers (Basel)       Date:  2015-04-10       Impact factor: 6.639

Review 7.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

8.  Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters.

Authors:  Simon Doran; Tina Gorjiara; Andrzej Kacperek; John Adamovics; Zdenka Kuncic; Clive Baldock
Journal:  Phys Med Biol       Date:  2015-01-02       Impact factor: 3.609

9.  Development of PHITS graphical user interface for simulation of positron emitting radioisotopes production in common biological materials during proton therapy.

Authors:  Mehrdad Shahmohammadi Beni; Kwan Ngok Yu; M Rafiqul Islam; Hiroshi Watabe
Journal:  J Radiat Res       Date:  2022-05-18       Impact factor: 2.724

10.  A novel method of estimating dose responses for polymer gels using texture analysis of scanning electron microscopy images.

Authors:  Cheng-Ting Shih; Jui-Ting Hsu; Rou-Ping Han; Bor-Tsung Hsieh; Shu-Jun Chang; Jay Wu
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.