[Comparison of quality on digital X-ray devices with 3D-capability for ENT-clinical objectives in imaging of temporal bone and paranasal sinuses].

M Knörgen1, S Brandt, S Kösling.   

Abstract

PURPOSE: Comparison of dosage and spatial resolution of digital X-Ray devices with 3D-capability in head and neck imaging.
MATERIALS AND METHODS: Three on-site X-Ray devices, a general purpose multi-slice CT (CT), a dedicated cone-beam CT (CBCT) and the CT-mode of a device for digital angiography (DSA) of the same generation were compared using paranasal sinus (PNS) and temporal bone imaging protocols. The radiation exposure was measured with a puncture measuring chamber on a CTDI head phantom as well as with chip-strate-dosimeters on an Alderson head phantom in the regions of the eyes and thyroid gland. By using the Alderson head phantom, the specific dosage of the X-Ray device with regard to different protocols was read out. For the assessment of the high-contrast resolution of the devices, images of a self-made phantom were qualitatively analysed by six observers.
RESULTS: The three devices showed marked variations in the dosage and spatial resolution depending on the protocol and/or modus. In both parameters, CBCT was superior to CT and DSA using standard protocols, with the difference being less obvious for the investigation with PNS.
CONCLUSION: For high-contrast investigations CBCT CT is a remarkable option in head and neck radiology. © Georg Thieme Verlag KG Stuttgart · New York.

Mesh:

Year:  2012        PMID: 23081736     DOI: 10.1055/s-0032-1325343

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  8 in total

Review 1.  [Modern imaging of the temporal bone].

Authors:  S Kösling
Journal:  HNO       Date:  2017-06       Impact factor: 1.284

2.  Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT.

Authors:  Robert Mlynski; Thi Dao Nguyen; Stefan K Plontke; Sabrina Kösling
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-03-26       Impact factor: 2.503

Review 3.  Diagnostic imaging modalities in head and neck disease.

Authors:  Florian Dammann; Friedrich Bootz; Mathias Cohnen; Stefan Hassfeld; Marcos Tatagiba; Sabrina Kösling
Journal:  Dtsch Arztebl Int       Date:  2014-06-09       Impact factor: 5.594

4.  [Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT].

Authors:  M K Pein; S Brandt; S K Plontke; S Kösling
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

5.  [Rare differential diagnosis of conductive hearing loss in childhood].

Authors:  M K Pein; T Rahne; A Noll; S K Plontke
Journal:  HNO       Date:  2018-10       Impact factor: 1.284

Review 6.  Spatial resolution in CBCT machines for dental/maxillofacial applications-what do we know today?

Authors:  D Brüllmann; R K W Schulze
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

7.  Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.

Authors:  T D Nguyen; S Kösling; R Mlynski; S K Plontke
Journal:  Eur Radiol       Date:  2016-03-30       Impact factor: 5.315

8.  CT imaging-based approaches to cochlear duct length estimation-a human temporal bone study.

Authors:  Tabita Breitsprecher; Anandhan Dhanasingh; Marko Schulze; Markus Kipp; Rami Abu Dakah; Tobias Oberhoffner; Michael Dau; Bernhard Frerich; Marc-André Weber; Soenke Langner; Robert Mlynski; Nora M Weiss
Journal:  Eur Radiol       Date:  2021-08-31       Impact factor: 5.315

  8 in total