PURPOSE: The purpose of this study was to characterise the biomechanical properties of the seven hole superior anterior clavicle LCP (locking compression plate) and to compare these with the properties of commonly applied implants used for the stabilisation of clavicular midshaft fractures such as the locking 7- and ten hole reconstruction plate. METHODS: Twenty-four synthetic clavicles were used. A transverse midshaft fracture was induced. The clavicles were fixed with angle stable clavicle LCPs, seven hole and ten hole reconstruction plates (n = 8 each). Twenty cycles of axial compression and torsion were performed for each sample, which was followed by 1,000 cycles of three point bending and ultimately bending to failure. Axial, torsional and cantilever bending stiffness were calculated from the data recorded. RESULTS: The clavicle LCP showed the highest overall stiffness compared to the seven and ten hole reconstruction plate. Significantly higher stiffness values were found for axial compression and external rotation. In the load-to-failure tests, the ten hole reconstruction plate especially showed early signs of plastic deformation, which might account for early plate insufficiency so frequently observed clinically. CONCLUSION: The results indicate that the clavicle LCP, as compared to the reconstruction plates, leads to superior biomechanical stability in the treatment of midshaft clavicle fractures.
PURPOSE: The purpose of this study was to characterise the biomechanical properties of the seven hole superior anterior clavicle LCP (locking compression plate) and to compare these with the properties of commonly applied implants used for the stabilisation of clavicular midshaft fractures such as the locking 7- and ten hole reconstruction plate. METHODS: Twenty-four synthetic clavicles were used. A transverse midshaft fracture was induced. The clavicles were fixed with angle stable clavicle LCPs, seven hole and ten hole reconstruction plates (n = 8 each). Twenty cycles of axial compression and torsion were performed for each sample, which was followed by 1,000 cycles of three point bending and ultimately bending to failure. Axial, torsional and cantilever bending stiffness were calculated from the data recorded. RESULTS: The clavicle LCP showed the highest overall stiffness compared to the seven and ten hole reconstruction plate. Significantly higher stiffness values were found for axial compression and external rotation. In the load-to-failure tests, the ten hole reconstruction plate especially showed early signs of plastic deformation, which might account for early plate insufficiency so frequently observed clinically. CONCLUSION: The results indicate that the clavicle LCP, as compared to the reconstruction plates, leads to superior biomechanical stability in the treatment of midshaft clavicle fractures.
Authors: Paul Celestre; Claire Roberston; Andrew Mahar; Richard Oka; Matthew Meunier; Alexandra Schwartz Journal: J Orthop Trauma Date: 2008-04 Impact factor: 2.512
Authors: Tarun Goswami; Ronald J Markert; Christopher G Anderson; Sandhya S Sundaram; Lynn A Crosby Journal: J Shoulder Elbow Surg Date: 2008-07-10 Impact factor: 3.019
Authors: Johannes Oppermann; Linda Ettmann; Carolin Meyer; Christian Ries; Gregor Stein; Christian Karl Spies; Lars Peter Müller; Christoph Faymonville Journal: Unfallchirurg Date: 2018-06 Impact factor: 1.000