Literature DB >> 18619865

Biomechanical evaluation of a pre-contoured clavicle plate.

Tarun Goswami1, Ronald J Markert, Christopher G Anderson, Sandhya S Sundaram, Lynn A Crosby.   

Abstract

Recent attention has been focused on the operative treatment of mid-shaft fractures of the clavicle. This study compares the in-vitro biomechanical properties of a pre-formed titanium clavicle plate (Acumed) to a Synthes 3.5 mm limited-contact dynamic-compression (LCDC) plate using a cadaveric osteotomy model. An osteotomy was performed on 7 pairs of human clavicles and were randomly plated with either a Synthes 3.5 mm LCDC stainless steel plate or an Acumed titanium pre-contoured clavicle plate. After plating, specimens were tested on an EnduraTEC material testing apparatus for axial compression and tension strength, as well as torsional strength in compression and tension. Biomechanical test results for plated specimens are reported for the LCDC plate and the Acumed plate, and the 2 plates are compared. This exploratory study supports investigations with larger sample sizes to determine if the Acumed pre-contoured plate differs from the LCDC plate in biomechanical properties and the clinical implications of such differences.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18619865     DOI: 10.1016/j.jse.2008.02.017

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  5 in total

1.  Internal fixation of displaced middle third fractures of clavicle with precontoured locking plate.

Authors:  Babu B Hundekar
Journal:  J Orthop       Date:  2013-05-15

2.  Precontoured plating of clavicle fractures: decreased hardware-related complications?

Authors:  Corinne VanBeek; Karen J Boselli; Edwin R Cadet; Christopher S Ahmad; William N Levine
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

3.  Displaced mid-shaft clavicular fractures: surgical treatment with a pre-contoured angular stability plate.

Authors:  Gabriele Campochiaro; Christos Tsatsis; Gabriele Gazzotti; Manuela Rebuzzi; Fabio Catani
Journal:  Musculoskelet Surg       Date:  2012-04-21

4.  Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation.

Authors:  Lars Eden; Stefanie Doht; Sönke P Frey; Dirk Ziegler; Jan Stoyhe; Kai Fehske; Torsten Blunk; Rainer H Meffert
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

5.  A systematic review of the use of titanium versus stainless steel implants for fracture fixation.

Authors:  Collin C Barber; Matthew Burnham; Ogaga Ojameruaye; Michael D McKee
Journal:  OTA Int       Date:  2021-08-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.