Literature DB >> 29098302

[Analysis of the accuracy of fit of five anatomically precontoured clavicle plate systems].

Johannes Oppermann1,2, Linda Ettmann3, Carolin Meyer3, Christian Ries3, Gregor Stein3, Christian Karl Spies4, Lars Peter Müller3,5, Christoph Faymonville3.   

Abstract

BACKGROUND: A common method in surgical treatment of midshaft clavicular fractures is the clavicle plating system. In addition to traditional osteosynthetic devices, anatomically preformed plate systems also exist. Advantages are described in greater accuracy of fit and less irritation of surrounding soft tissues. The purpose of this study was to compare the anatomical fit of five different precontoured clavicle plating systems.
MATERIAL AND METHODS: The anatomical fit of five different types of anatomical precontoured clavicle plates, 3 times VariaxSystem® (Stryker, Kalamazoo, MI), Meves® Plate (Ulrich medical Ulm, Germany) and LCP clavicle plate (Synthes, Bettlach, Switzerland) were investigated in 20 embalmed human cadaveric clavicles. An imprint of the space between the well-positioned plate and the clavicle was obtained using a silicone mass and the silicone imprint was digitally measured. Additionally, the anatomical fit was evaluated by three investigators following a standardized protocol (+2 to -2 points at lateral, midshaft and medial clavicle portions).
RESULTS: The first three ranks went to the Stryker Variax-plates. They showed the least distance (Stryker 628027: 7‑hole 1.44 mm, low curvature 0.93 mm-2.36 mm, 2. Stryker 628028: 8‑hole low curvature 1.68 mm, 1.03 mm-2.4 mm and 3. Stryker 628128: 8‑hole high curvature 1.87 mm, range 1.09 mm-3.1 mm) The evaluation of the anatomical fit by the investigators was in agreement with the measurement results.
CONCLUSION: Although there was no complete congruency between the plates and the clavicle, all clavicle plates investigated in this study presented a reasonable anatomical shape. The 7‑hole VariAx Stryker plate with slight curvature showed the best anatomical fit. A low profile and optimized anatomical precontouring can minimize irritation of the surrounding soft tissues and should be considered in plate design and implant choice.

Entities:  

Keywords:  Anatomical fit; Clavicle fracture; Plate system; Precontoured; Treatment

Mesh:

Year:  2018        PMID: 29098302     DOI: 10.1007/s00113-017-0433-z

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  22 in total

1.  [30 years of osteosynthesis: developments in surgical fracture treatment over the last three decades].

Authors:  K Weise
Journal:  Orthopade       Date:  2010-02       Impact factor: 1.087

2.  Distal radius: anatomical morphometric gender characteristics. Do anatomical pre-shaped plates pay attention on it?

Authors:  Johannes Oppermann; Jan Bredow; Frank Beyer; Wolfram Friedrich Neiss; Christian K Spies; Peer Eysel; Jens Dargel; Max Wacker
Journal:  Arch Orthop Trauma Surg       Date:  2014-11-12       Impact factor: 3.067

3.  Operative versus nonoperative treatment for displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials.

Authors:  Lingde Kong; Yingze Zhang; Yong Shen
Journal:  Arch Orthop Trauma Surg       Date:  2014-08-29       Impact factor: 3.067

4.  Superior versus anteroinferior plating of clavicle fractures.

Authors:  Nathan Formaini; Benjamin C Taylor; Jeffrey Backes; Thomas J Bramwell
Journal:  Orthopedics       Date:  2013-07       Impact factor: 1.390

5.  Long-term outcomes of clavicular pseudoarthrosis therapy.

Authors:  I Petrovic; S Davila; I Premuzic; N Zdunić; R Trotic; M Prutki
Journal:  J Surg Res       Date:  2004-10       Impact factor: 2.192

Review 6.  Operative versus nonoperative care of displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials.

Authors:  Robbin C McKee; Daniel B Whelan; Emil H Schemitsch; Michael D McKee
Journal:  J Bone Joint Surg Am       Date:  2012-04-18       Impact factor: 5.284

7.  Displaced mid-shaft clavicular fractures: surgical treatment with a pre-contoured angular stability plate.

Authors:  Gabriele Campochiaro; Christos Tsatsis; Gabriele Gazzotti; Manuela Rebuzzi; Fabio Catani
Journal:  Musculoskelet Surg       Date:  2012-04-21

8.  Locked intramedullary fixation vs plating for displaced and shortened mid-shaft clavicle fractures: a randomized clinical trial.

Authors:  Nicholas A Ferran; Paul Hodgson; Nicola Vannet; Rhys Williams; Richard O Evans
Journal:  J Shoulder Elbow Surg       Date:  2010-09       Impact factor: 3.019

9.  [Surgical treatment of diaphyseal and comminuted fractures of the clavicle using a low profile anatomical plate].

Authors:  E Moya; C Lamas; M Almenara; I Proubasta
Journal:  Rev Esp Cir Ortop Traumatol       Date:  2012-02-23

10.  Clavicular anatomy and the applicability of precontoured plates.

Authors:  Jerry I Huang; Paul Toogood; Michael R Chen; John H Wilber; Daniel R Cooperman
Journal:  J Bone Joint Surg Am       Date:  2007-10       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.