Dual-energy CT for the evaluation of silicone breast implants.

Thorsten R C Johnson1, Isabelle Himsl, Karin Hellerhoff, Doris Mayr, Dorothea Rjosk-Dendorfer, Nina Ditsch, Bernhard Krauss, Klaus Friese, Maximilian F Reiser, Miriam S Lenhard.   

Abstract

OBJECTIVE: The evaluation of breast implants for rupture is currently the domain of ultrasound and MRI, while mammography is of very limited diagnostic value. Recently, specific visualisation of silicone has become feasible using dual-energy CT. Our objective was to evaluate whether it is feasible to identify silicone in breast implants by dual-energy CT and to reliably diagnose or rule out ruptures.
METHODS: Seven silicone breast implant specimens were examined on dual-source CT at 100- and 140-kV tube potential with a 0.8-mm tin filter (collimation 128 × 0.6 mm, current-time products 165 and 140 mAsref with modulation, rotation time 0.28 s, pitch 0.55). Two patients scheduled for implant removal or replacement were examined with identical parameters.
RESULTS: The silicone of the implant specimens showed a strong dual-energy signal. In one patient, both implants were intact, while a rupture was identified in the other patient. Ultrasound, MRI, surgical findings and histology confirmed the dual-energy CT diagnosis.
CONCLUSION: Dual-energy CT may serve as an alternative technique for speedy evaluation of silicone breast implants. Specific clinical studies are required to determine the diagnostic accuracy and define indications for this technique.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23064715     DOI: 10.1007/s00330-012-2667-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  The implications of PIP are more than just cosmetic.

Authors:  Richard Smith; Neil Lunt; Johanna Hanefeld
Journal:  Lancet       Date:  2012-02-02       Impact factor: 79.321

2.  Discussion: Prevalence of rupture in poly implant Prothèse silicone breast implants, recalled from the European market in 2010.

Authors:  Dennis C Hammond
Journal:  Plast Reconstr Surg       Date:  2012-06       Impact factor: 4.730

3.  Clinical and imaging characteristics of Polyimplant Prosthesis hydrogel breast implants.

Authors:  Jae Jeong Choi; Jae Hee Lee; Bong Joo Kang; Sung Hun Kim; Ji Hye Lee; Sang Tae Ahn; Won Jun Yoon; Hong Ki Lee
Journal:  J Comput Assist Tomogr       Date:  2010 May-Jun       Impact factor: 1.826

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 5.  The diagnosis of silicone breast implant rupture.

Authors:  David P Gorczyca; Stephanie M Gorczyca; Kathryn L Gorczyca
Journal:  Plast Reconstr Surg       Date:  2007-12       Impact factor: 4.730

6.  Water-silicone separated volumetric MR acquisition for rapid assessment of breast implants.

Authors:  Ananth J Madhuranthakam; Martin P Smith; Huanzhou Yu; Ann Shimakawa; Scott B Reeder; Neil M Rofsky; Charles A McKenzie; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2012-01-13       Impact factor: 4.813

7.  Breast implant rupture: diagnosis with US.

Authors:  C I Caskey; W A Berg; N D Anderson; S Sheth; B W Chang; U M Hamper
Journal:  Radiology       Date:  1994-03       Impact factor: 11.105

8.  Prevalence of rupture in poly implant Prothèse silicone breast implants, recalled from the European market in 2010.

Authors:  Maria C Maijers; Francisus B Niessen
Journal:  Plast Reconstr Surg       Date:  2012-06       Impact factor: 4.730

9.  [Breast augmentation by Poly Implant Prothèses silicone implants: retrospective study about 99 patients. Rupture analysis and management].

Authors:  A Aktouf; I Auquit-Auckbur; D Coquerel-Beghin; V Delpierre; P-Y Milliez
Journal:  Ann Chir Plast Esthet       Date:  2012-05-29       Impact factor: 0.660

10.  Sonographic signs of breast implant rupture.

Authors:  L A Venta; C G Salomon; M E Flisak; E R Venta; R Izquierdo; J Angelats
Journal:  AJR Am J Roentgenol       Date:  1996-06       Impact factor: 3.959

View more
  5 in total

Review 1.  Imaging findings of mammary and systemic silicone deposition secondary to breast implants.

Authors:  Naziya Samreen; Katrina N Glazebrook; Asha Bhatt; Sudhakar K Venkatesh; Brendan P McMenomy; Anupam Chandra; Shuai Leng; Kalie E Adler; Cynthia H McCollough
Journal:  Br J Radiol       Date:  2018-05-10       Impact factor: 3.039

Review 2.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Joel G Fletcher
Journal:  Radiology       Date:  2015-09       Impact factor: 11.105

3.  Breast cancer: comparison of quantitative dual-layer spectral CT and axillary ultrasonography for preoperative diagnosis of metastatic axillary lymph nodes.

Authors:  Thomas Winther Buus; Mads Sandahl; Kennet Sønderstgaard Thorup; Finn Rasmussen; Søren Redsted; Peer Christiansen; Anders Bonde Jensen; Erik Morre Pedersen
Journal:  Eur Radiol Exp       Date:  2021-04-09

4.  Dual-Energy CT for Evaluation of Intra- and Extracapsular Silicone Implant Rupture.

Authors:  Katrina N Glazebrook; Shuai Leng; Steven R Jacobson; Cynthia M McCollough
Journal:  Case Rep Radiol       Date:  2016-01-28

5.  Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences.

Authors:  Lisa Ruby; Sojin Shim; Nicole Berger; Magda Marcon; Thomas Frauenfelder; Andreas Boss
Journal:  Medicine (Baltimore)       Date:  2020-07-24       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.