Evaluation of a fiberoptic intracranial pressure monitor.

J S Crutchfield1, R K Narayan, C S Robertson, L H Michael.   

Abstract

The fiberoptic device is a relatively new type of intracranial pressure (ICP) monitor which appears to offer certain advantages over conventional monitoring systems, particularly its ability to measure brain parenchymal pressures. This study was undertaken to analyze the accuracy and drift characteristics of the fiberoptic device and to compare pressures in the subdural, intraparenchymal, and intraventricular compartments. The device was accurate to +/- 3 mm Hg over a 0- to 30-mm Hg range in vitro. The maximum daily drift was +/- 2.5 mm Hg, with an average daily drift of +/- 0.6 mm Hg and an average drift over a 5-day period of +/- 2.1 mm Hg. In vivo, the pressures and waveform characteristics obtained with the fiberoptic device and with a strain-gauge transducer connected to a ventriculostomy were very similar. Alterations in ICP were induced by various therapeutic and pathological manipulations, and the pressures in the three intracranial compartments were compared. Changes in ICP appeared to be reflected simultaneously and equally in all three compartments. Furthermore, changes in ICP secondary to a unilateral mass lesion were identical in both supratentorial parenchymal compartments when measured simultaneously. It is concluded that the fiberoptic device is an accurate and reliable system for ICP monitoring; the pressures recorded in the subdural, intraparenchymal, and intraventricular compartments paralleled each other in all of the physiological and pathological states tested. Although the drift associated with this device is less than that reported for previously available systems, its maximal cumulative drift over a 5-day period of +/- 6 mm Hg is significant. Since the fiberoptic device cannot be recalibrated in situ, it is suggested that the device be replaced if monitoring is to be continued for periods longer than 5 days.

Mesh:

Year:  1990        PMID: 2303881     DOI: 10.3171/jns.1990.72.3.0482

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  15 in total

1.  Complications of brain tissue pressure monitoring with a fiberoptic device.

Authors:  A Bekar; S Gören; E Korfali; K Aksoy; S Boyaci
Journal:  Neurosurg Rev       Date:  1998       Impact factor: 3.042

Review 2.  Analysis of intracranial pressure.

Authors:  D J Doyle; P W Mark
Journal:  J Clin Monit       Date:  1992-01

3.  A new method for long-term lumbar pressure monitoring with a fiber optic catheter.

Authors:  H G Bolander
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

4.  Comparative analysis between epidural (Gaeltec) and subdural (Camino) intracranial pressure probes.

Authors:  C Weinstabl; B Richling; B Plainer; T Czech; C K Spiss
Journal:  J Clin Monit       Date:  1992-04

5.  Epidural intracranial pressure measurement in rats using a fiber-optic pressure transducer.

Authors:  Lucy Murtha; Damian McLeod; Neil Spratt
Journal:  J Vis Exp       Date:  2012-04-25       Impact factor: 1.355

Review 6.  Bedside burr hole for intracranial pressure monitoring performed by intensive care physicians. A 5-year experience.

Authors:  M Bochicchio; N Latronico; S Zappa; A Beindorf; A Candiani
Journal:  Intensive Care Med       Date:  1996-10       Impact factor: 17.440

7.  A comparison of extradural and intraparenchymatous intracranial pressures in head injured patients.

Authors:  N Bruder; P N'Zoghe; N Graziani; D Pelissier; F Grisoli; G François
Journal:  Intensive Care Med       Date:  1995-10       Impact factor: 17.440

Review 8.  Head injury.

Authors:  J D Miller
Journal:  J Neurol Neurosurg Psychiatry       Date:  1993-05       Impact factor: 10.154

9.  Clinical experience with a fiberoptic intracranial pressure monitor.

Authors:  J S Yablon; H J Lantner; T M McCormack; S Nair; E Barker; P Black
Journal:  J Clin Monit       Date:  1993-07

10.  Intracranial pressure monitoring in children: comparison of external ventricular device with the fiberoptic system.

Authors:  G Gambardella; C Zaccone; E Cardia; F Tomasello
Journal:  Childs Nerv Syst       Date:  1993-12       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.