| Literature DB >> 23008777 |
José Maurício Dos Santos Nunes Reis1, Erica Gouveia Jorge, João Gustavo Rabelo Ribeiro, Ligia Antunes Pereira Pinelli, Filipe de Oliveira Abi-Rached, Mário Tanomaru-Filho.
Abstract
Objective. The aim of this study was to evaluate the radiopacity of two conventional cements (Zinc Cement and Ketac Cem Easymix), one resin-modified glass ionomer cement (RelyX Luting 2) and six resin cements (Multilink, Bistite II DC, RelyX ARC, Fill Magic Dual Cement, Enforce and Panavia F) by digitization of images. Methods. Five disc-shaped specimens (10 × 1.0 mm) were made for each material, according to ISO 4049. After setting of the cements, radiographs were made using occlusal films and a graduated aluminum stepwedge varying from 1.0 to 16 mm in thickness. The radiographs were digitized, and the radiopacity of the cements was compared with the aluminum stepwedge using the software VIXWIN-2000. Data (mmAl) were submitted to one-way ANOVA and Tukey's test (α = 0.05). Results. The Zinc Cement was the most radiopaque material tested (P < 0.05). The resin cements presented higher radiopacity (P < 0.05) than the conventional (Ketac Cem Easymix) or resin-modified glass ionomer (RelyX Luting 2) cements, except for the Fill Magic Dual Cement and Enforce. The Multilink presented the highest radiopacity (P < 0.05) among the resin cements. Conclusion. The glass ionomer-based cements (Ketac Cem Easymix and RelyX Luting 2) and the resin cements (Fill Magic Dual Cement and Enforce) showed lower radiopacity values than the minimum recommended by the ISO standard.Entities:
Year: 2012 PMID: 23008777 PMCID: PMC3449120 DOI: 10.5402/2012/704246
Source DB: PubMed Journal: ISRN Dent ISSN: 2090-4371
Luting cements tested.
| Product | Code | Type | Manufacturer |
|---|---|---|---|
| Zinc Cement | ZP | Zinc phosphate | S.S. White Ltda., Rio de Janeiro, RJ, Brazil |
| Ketac Cem Easymix | KC | Glass ionomer | 3M ESPE, St. Paul, MN, USA |
| RelyX Luting 2 | RXL | Self-curing resin-modified glass ionomer | 3M ESPE, St. Paul, MN, USA |
| Multilink | ML | Autopolymerizing resin | Ivoclar-Vivadent, Schaan, Liechtenstein, Germany |
| Bistite II DC | BII | Dual-polymerizing resin | Tokuyama Dental Corporation, Taitou-Ku, Tokyo, Japan |
| RelyX ARC | RXA | Dual-polymerizing resin | 3M ESPE, St. Paul, MN, USA |
| Fill Magic Dual Cement | DC | Dual-polymerizing resin | Vigodent S/A, Rio de Janeiro, RJ, Brazil |
| Enforce | EF | Dual-polymerizing resin | Dentsply Indústria e Comércio Ltda., Petrópolis, RJ, Brazil |
| Panavia F | PF | Dual-polymerizing resin | Kuraray Medical Inc., Kurashiki, Okayama, Japan |
Figure 1Radiographic film obtained with one disc of each material and the graduated aluminum stepwedge.
Figure 2Mean radiopacity values and standard deviation (vertical bars) of the materials, and the results of Tukey's HSD post hoc test. Columns with the same letter were not statistically different (P > 0.05).