Literature DB >> 17916070

Evaluation of the radiopacity of calcium hydroxide- and glass-ionomer-based root canal sealers.

M Tanomaru-Filho1, E G Jorge, J M G Tanomaru, M Gonçalves.   

Abstract

AIM: To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).
METHODOLOGY: Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.
RESULTS: Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).
CONCLUSIONS: The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17916070     DOI: 10.1111/j.1365-2591.2007.01309.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  In vitro comparison of the radiopacity of cavity lining materials with human dental structures.

Authors:  Fernanda Cp Pires de Souza; Luiz C Pardini; Diogo R Cruvinel; Hisham M Hamida; Lucas Fr Garcia
Journal:  J Conserv Dent       Date:  2010-04

2.  A microcomputed tomography-based comparison of root canal filling quality following different instrumentation and obturation techniques.

Authors:  Anna Kierklo; Zbisław Tabor; Małgorzata Pawińska; Małgorzata Jaworska
Journal:  Med Princ Pract       Date:  2014-10-25       Impact factor: 1.927

3.  Radiopacity evaluation of contemporary luting cements by digitization of images.

Authors:  José Maurício Dos Santos Nunes Reis; Erica Gouveia Jorge; João Gustavo Rabelo Ribeiro; Ligia Antunes Pereira Pinelli; Filipe de Oliveira Abi-Rached; Mário Tanomaru-Filho
Journal:  ISRN Dent       Date:  2012-09-13

4.  Influence of root canal sealer on the radiographic appearance of filling voids in maxillary single-rooted teeth.

Authors:  Augusto Bodanezi; Etiene Andrade Munhoz; Ana Lúcia Álvares Capelozza; Norberti Bernardineli; Ivaldo Gomes de Moraes; Roberto Brandão Garcia; Clovis Monteiro Bramante
Journal:  J Appl Oral Sci       Date:  2012 Jul-Aug       Impact factor: 2.698

5.  Physicochemical properties of endodontic sealers of different bases.

Authors:  Gabriela Alexandra Marín-Bauza; Yara Teresinha Correa Silva-Sousa; Suely Aparecida da Cunha; Fuad Jacob Abi Rached-Junior; Idomeo Bonetti-Filho; Manoel Damião Sousa-Neto; Carlos Eduardo Saraiva Miranda
Journal:  J Appl Oral Sci       Date:  2012 Jul-Aug       Impact factor: 2.698

  5 in total