Literature DB >> 20416413

A descriptive study of the radiographic density of implant restorative cements.

Chandur Wadhwani1, Timothy Hess, Thomas Faber, Alfonso Piñeyro, Curtis S K Chen.   

Abstract

STATEMENT OF PROBLEM: Cementation of implant prostheses is a common practice. Excess cement in the gingival sulcus may harm the periodontal tissues. Identification of the excess cement may be possible with the use of radiographs if the cement has sufficient radiopacity.
PURPOSE: The purpose of this study was to compare the radiographic density of different cements used for implant prostheses.
MATERIAL AND METHODS: Eight different cements were compared: TempBond Original (TBO), TempBond NE (TBN), Fleck's (FL), Dycal (DY), RelyX Unicem (RXU), RelyX Luting (RXL), Improv (IM), and Premier Implant Cement (PIC). Specimen disks, 2 mm in thickness, were radiographed. Images were made using photostimulable phosphor (PSP) plates with standardized exposure values. The average grey level of the central area of each specimen disk was selected and measured in pixels using a software analysis program, ImageTool, providing an average grey level value representative of radiodensity for each of the 8 cements. The radiodensity was determined using the grey level values of the test materials, which were recorded and compared to a standard aluminum step wedge. An equivalent thickness of aluminum in millimeters was calculated using best straight line fit estimates. To assess contrast effects by varying the exposure settings, a second experiment using 1-mm-thick cement specimens radiographed at both 60 kVp and 70 kVp was conducted. The PSP plates with specimens were measured for a grey level value comparison to the standard aluminum step wedge, using the same software program.
RESULTS: The highest grey level values were recorded for the zinc cements (TBO, TBN, and FL), with the 1-mm specimen detectable at both 60- and 70-kVp settings. A lower grey level was recorded for DY, indicative of a lower radiodensity compared to the zinc cements, but higher than RXL and RXU. The implant-specific cements had the lowest grey level values. IM could only be detected in 2-mm-thick sections with a lower aluminum equivalence value than the previously mentioned cements. PIC could not be detected radiographically for either the 1-mm or 2-mm thicknesses at either of the kVp settings.
CONCLUSIONS: Some types of cement commonly used for the cementation of implant-supported prostheses have poor radiodensity and may not be detectable following radiographic examination.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20416413     DOI: 10.1016/S0022-3913(10)60062-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Effect of various surface treatments on the retention properties of titanium to implant restorative cement.

Authors:  Hakan Akin; Umit Guney
Journal:  Lasers Med Sci       Date:  2011-11-29       Impact factor: 3.161

2.  Comparison of Tooth Color Change After Bleaching With Conventional and Different Light-Activated Methods.

Authors:  Sima Shahabi; Hadi Assadian; Alireza Mahmoudi Nahavandi; Hanieh Nokhbatolfoghahaei
Journal:  J Lasers Med Sci       Date:  2017-12-26

3.  Evaluation of radiopacities of CAD/CAM restorative materials and resin cements by digital radiography.

Authors:  Zerrin Unal Erzurumlu; Cennet Elcin Sagirkaya; Kerem Erzurumlu
Journal:  Clin Oral Investig       Date:  2021-03-11       Impact factor: 3.606

4.  Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures.

Authors:  Dennis Flanagan
Journal:  Clin Cosmet Investig Dent       Date:  2017-11-03

5.  Radiopacity evaluation of contemporary luting cements by digitization of images.

Authors:  José Maurício Dos Santos Nunes Reis; Erica Gouveia Jorge; João Gustavo Rabelo Ribeiro; Ligia Antunes Pereira Pinelli; Filipe de Oliveira Abi-Rached; Mário Tanomaru-Filho
Journal:  ISRN Dent       Date:  2012-09-13

6.  Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge.

Authors:  Arash Poorsattar Bejeh Mir; Morvarid Poorsattar Bejeh Mir
Journal:  Imaging Sci Dent       Date:  2012-09-21

7.  Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions.

Authors:  Raquel Venâncio Fernandes Dantas; Hugo Ramalho Sarmento; Rosângela Marques Duarte; Sônia Saeger Meireles Monte Raso; Ana Karina Maciel de Andrade; Maria Luiza Dos Anjos-Pontual
Journal:  Imaging Sci Dent       Date:  2013-09-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.