Literature DB >> 1432765

Effect of seating force on film thickness of new adhesive luting agents.

S N White1, Z Yu, V Kipnis.   

Abstract

This study examined the effect of seating force on the film thickness of new adhesive luting agents. The method was in compliance with American National Standards/American Dental Association Specification No. 8 for zinc phosphate cement. The materials tested were zinc phosphate cement, glass ionomer cement, polycarboxylate cement, and a resinous cement with a dentinal bonding agent. All materials were manipulated exactly as described in the manufacturer's instructions, and an electronic gauge with an accuracy of 0.5 micron was used. Each class of material was measured 10 times at six different seating forces. Analysis of variance and multiple comparisons testing disclosed that the seating force and class of material strongly influenced the film thicknesses of luting agents. A mathematical model describing the response of zinc phosphate cement within the range tested was reported.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1432765     DOI: 10.1016/0022-3913(92)90414-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

Authors:  Raquel Castillo-de-Oyagüe; Andrés Sánchez-Turrión; José-Francisco López-Lozano; Alberto Albaladejo; Daniel Torres-Lagares; Javier Montero; Maria-Jesús Suárez-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

2.  Effects of Finger Pressure Applied By Dentists during Cementation of All-Ceramic Crowns.

Authors:  Mustafa Zortuk; Pınar Bolpaca; Kerem Kilic; Eylem Ozdemir; Suleyman Aguloglu
Journal:  Eur J Dent       Date:  2010-10

3.  Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study.

Authors:  Balaji N Rajan; Srinivasan Jayaraman; Baburajan Kandhasamy; Ilangkumaran Rajakumaran
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

4.  Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.

Authors:  Mi-Jung Yun; Young-Chan Jeon; Chang-Mo Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

5.  Radiopacity evaluation of contemporary luting cements by digitization of images.

Authors:  José Maurício Dos Santos Nunes Reis; Erica Gouveia Jorge; João Gustavo Rabelo Ribeiro; Ligia Antunes Pereira Pinelli; Filipe de Oliveira Abi-Rached; Mário Tanomaru-Filho
Journal:  ISRN Dent       Date:  2012-09-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.