BACKGROUND: Imaging of the urinary tract and its surrounding tissue still remains challenging, since standard imaging in the urological operation room consists of fluoroscopy and plain X-rays. The combination of a ceiling-mounted X-ray system and a new urological intervention table now allows cross-sectional imaging and 3D reconstruction to be performed in the endourological operation room (Urological Dyna-CT).
MATERIALS AND METHODS: The imaging quality of the Artis Zee Ceiling (Siemens Medical Solutions, Erlangen, Germany) was assessed using slice images of an ex vivo pig kidney model prepared with artificial stones (plaster of Paris). We compared the image quality of three different examination protocols with this model. 3D reconstruction quality was illustrated by means of retrograde filling of one pig`s urinary tract with a diluted contrast medium.
RESULTS: Interventional stone detection and localization is possible with a 5 s low-dose Urological Dyna-CT. Detailed imaging of the collecting system by retrograde pyelography is possible with a high image quality.
CONCLUSION: The combination of an Artis Zee(®) Ceiling (Siemens Medical Solutions, Erlangen, Germany) with our newly developed urological intervention table we call the Urological Dyna-CT. In addition to such standard procedures as fluoroscopy or plain X-rays, cross-sectional imaging and 3D reconstruction of the urinary tract are possible and provide fast and excellent urological imaging.

Entities:  

Mesh:

Year:  2012        PMID: 22996760     DOI: 10.1007/s00345-012-0951-9

Source DB:  PubMed          Journal:  World J Urol        ISSN: 0724-4983            Impact factor:   4.226


  10 in total

1.  Real-Time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility.

Authors:  S J Braak; M J L van Strijen; M van Leersum; H W van Es; J P M van Heesewijk
Journal:  AJR Am J Roentgenol       Date:  2010-05       Impact factor: 3.959

2.  Radiation exposure during endourologic procedures using over-the-table fluoroscopy sources.

Authors:  Manuel Ritter; Patrick Krombach; Andreas Martinschek; Fabian P Siegel; Martin Schmitt; Christel Weiss; Axel Häcker; Alexandre E Pelzer
Journal:  J Endourol       Date:  2011-10-17       Impact factor: 2.942

3.  Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector.

Authors:  Sergin Akpek; Thomas Brunner; Goetz Benndorf; Charles Strother
Journal:  Diagn Interv Radiol       Date:  2005-03       Impact factor: 2.630

4.  Dyna-CT during minimally invasive off-pump transapical aortic valve implantation.

Authors:  Jörg Kempfert; Volkmar Falk; Gerhard Schuler; Axel Linke; Denis Merk; Friedrich W Mohr; Thomas Walther
Journal:  Ann Thorac Surg       Date:  2009-12       Impact factor: 4.330

5.  C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis.

Authors:  Simon C Leschka; Drazenko Babic; Samer El Shikh; Christine Wossmann; Martin Schumacher; Christian A Taschner
Journal:  Neuroradiology       Date:  2011-04-08       Impact factor: 2.804

6.  Real-time 3D fluoroscopy-guided large core needle biopsy of renal masses: a critical early evaluation according to the IDEAL recommendations.

Authors:  Stephanie G C Kroeze; Merel Huisman; Helena M Verkooijen; Paul J van Diest; J L H Ruud Bosch; Maurice A A J van den Bosch
Journal:  Cardiovasc Intervent Radiol       Date:  2011-08-06       Impact factor: 2.740

Review 7.  Evolution of urological imaging.

Authors:  Anton J Bueschen; Mark E Lockhart
Journal:  Int J Urol       Date:  2010-11-29       Impact factor: 3.369

8.  Initial observations of endovascular aneurysm repair using Dyna-CT.

Authors:  Kari Ravn Eide; Asbjørn Ødegård; Hans Olav Myhre; Olav Haraldseth
Journal:  J Endovasc Ther       Date:  2007-02       Impact factor: 3.487

9.  The utility of DynaCT in neuroendovascular procedures.

Authors:  N S Heran; J K Song; K Namba; W Smith; Y Niimi; A Berenstein
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

10.  Effectiveness of three-dimensional fluoroscopy in percutaneous nephrostomy: an animal model study.

Authors:  Federico Soria; M Inmaculada Delgado; Francisco M Sánchez; Antonio Allona; J Fernando Jiménez Cruz; Enrique Morell; Jesús Usón
Journal:  Urology       Date:  2008-12-18       Impact factor: 2.649

  10 in total
  1 in total

1.  Accuracy in detecting and measuring residual fragments with the Uro Dyna-CT.

Authors:  B Meister; M C Rassweiler; C Weiß; A Häcker; M Ritter
Journal:  World J Urol       Date:  2014-08-28       Impact factor: 4.226

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.