Literature DB >> 15795836

Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector.

Sergin Akpek1, Thomas Brunner, Goetz Benndorf, Charles Strother.   

Abstract

We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images. Present status of the technique, advantages and potential applications are discussed.

Entities:  

Mesh:

Year:  2005        PMID: 15795836

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  40 in total

1.  Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model.

Authors:  M Ritter; M-C Rassweiler; A Häcker; M S Michel
Journal:  World J Urol       Date:  2012-03-04       Impact factor: 4.226

2.  Development of a cardiac evaluation method using a dynamic flat-panel detector (FPD) system: a feasibility study using a cardiac motion phantom.

Authors:  Rie Tanaka; Shigeru Sanada; Katsumi Tsujioka; Takeshi Matsui; Tadanori Takata; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2007-11-01

3.  Flat panel catheter angiotomography of the spinal venous system: an enhanced venous phase for spinal digital subtraction angiography.

Authors:  J Chen; T Ethiati; P Gailloud
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

4.  Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor.

Authors:  Reiichi Ishikura; Kumiko Ando; Yuki Nagami; Satoshi Yamamoto; Koui Miura; Ajaya Raj Pande; Tosyiko Yamano; Shozo Hirota; Norio Nakao
Journal:  Radiat Med       Date:  2006-06

5.  A cone-beam volume CT using a 3D angiography system with a flat panel detector of direct conversion type: usefulness for superselective intra-arterial chemotherapy for head and neck tumors.

Authors:  S Kakeda; Y Korogi; Y Miyaguni; J Moriya; N Ohnari; N Oda; K Nishino; W Miyamoto
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-20       Impact factor: 3.825

6.  Feasibility study of perfusion imaging using flat detector CT with an intra-arterial injection protocol compared to conventional multi-slice perfusion CT with an intravenous injection protocol.

Authors:  Qiang Zhang; Bin Wang; Jingfeng Han; Zhiqiang Zhang; Qi Sun; Janina Beilner; Chunsen Shen; Zijun He; Yiwu Dai; Ruxiang Xu
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

7.  Use of cone-beam computed tomography angiography in planning for gamma knife radiosurgery for arteriovenous malformations: a case series and early report.

Authors:  Mina G Safain; Jason P Rahal; Ami Raval; Mark J Rivard; John E Mignano; Julian K Wu; Adel M Malek
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

8.  Quantitative assessment of lipiodol deposition after chemoembolization: comparison between cone-beam CT and multidetector CT.

Authors:  Rongxin Chen; Jean-François Geschwind; Zhijun Wang; Vania Tacher; MingDe Lin
Journal:  J Vasc Interv Radiol       Date:  2013-10-01       Impact factor: 3.464

9.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

10.  C-arm CT measurement of cerebral blood volume in ischemic stroke: an experimental study in canines.

Authors:  T Bley; C M Strother; K Pulfer; K Royalty; M Zellerhoff; Y Deuerling-Zheng; F Bender; D Consigny; R Yasuda; D Niemann
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-06       Impact factor: 3.825

View more