Literature DB >> 21822769

Real-time 3D fluoroscopy-guided large core needle biopsy of renal masses: a critical early evaluation according to the IDEAL recommendations.

Stephanie G C Kroeze1, Merel Huisman, Helena M Verkooijen, Paul J van Diest, J L H Ruud Bosch, Maurice A A J van den Bosch.   

Abstract

INTRODUCTION: Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses.
METHODS: Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluated according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations.
RESULTS: Median tumor size was 2.6 (range, 1.0-14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4-19.8) months.
CONCLUSIONS: 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses<2.5 cm.

Entities:  

Mesh:

Year:  2011        PMID: 21822769     DOI: 10.1007/s00270-011-0237-4

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  10 in total

1.  Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance: a phantom study.

Authors:  Nils Rathmann; Michael Kostrzewa; Kerim Kara; Soenke Bartling; Holger Haubenreisser; Stefan O Schoenberg; Steffen J Diehl
Journal:  Br J Radiol       Date:  2015-09-15       Impact factor: 3.039

2.  Cone beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance.

Authors:  W M H Busser; S J Braak; J J Fütterer; M J L van Strijen; Y L Hoogeveen; F de Lange; L J Schultze Kool
Journal:  Br J Radiol       Date:  2013-08-02       Impact factor: 3.039

3.  The Urological Dyna-CT: ex vivo feasibility study of interventional cross-sectional imaging in the endourological operation room.

Authors:  M S Michel; M Ritter; H Wertz; S Schönberg; A Häcker; G Weisser
Journal:  World J Urol       Date:  2012-09-21       Impact factor: 4.226

4.  [New puncture techniques in urology using 3D-assisted imaging].

Authors:  M Ritter; M-C Rassweiler; J J Rassweiler; M S Michel
Journal:  Urologe A       Date:  2012-12       Impact factor: 0.639

5.  Real-time X-ray-based 4D image guidance of minimally invasive interventions.

Authors:  Jan Kuntz; Rajiv Gupta; Stefan O Schönberg; Wolfhard Semmler; Marc Kachelrieß; Sönke Bartling
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

6.  Target visibility enhancement for C-arm cone beam CT-fluoroscopy-guided hepatic needle placement: implementation and accuracy evaluation.

Authors:  Mengjiao Wang; Hui Ding; Xiaodong Wang; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-16       Impact factor: 2.924

7.  Evaluation of percutaneous biopsies of renal masses under MRI-guidance: a retrospective study about 26 cases.

Authors:  J Garnon; A Schlier; X Buy; G Tsoumakidou; M de Mathelin; E Breton; A Gangi
Journal:  Eur Radiol       Date:  2014-10-15       Impact factor: 5.315

8.  Torsional dynamics of steerable needles: modeling and fluoroscopic guidance.

Authors:  John P Swensen; MingDe Lin; Allison M Okamura; Noah J Cowan
Journal:  IEEE Trans Biomed Eng       Date:  2014-05-21       Impact factor: 4.538

9.  Frameless multimodal image guidance of localized convection-enhanced delivery of therapeutics in the brain.

Authors:  Imramsjah M J van der Bom; Richard P Moser; Guanping Gao; Miguel Sena-Esteves; Neil Aronin; Matthew J Gounis
Journal:  J Neurointerv Surg       Date:  2011-12-22       Impact factor: 5.836

Review 10.  Outcome selection, measurement and reporting for new surgical procedures and devices: a systematic review of IDEAL/IDEAL-D studies to inform development of a core outcome set.

Authors:  R C Macefield; N Wilson; C Hoffmann; J M Blazeby; A G K McNair; K N L Avery; S Potter
Journal:  BJS Open       Date:  2020-10-04
  10 in total