Literature DB >> 22992979

A miniaturized transcutaneous system for continuous glucose monitoring.

Robert A Croce1, SanthiSagar Vaddiraju, Jun Kondo, Yan Wang, Liang Zuo, Kai Zhu, Syed K Islam, Diane J Burgess, Fotios Papadimitrakopoulos, Faquir C Jain.   

Abstract

Implantable sensors for continuous glucose monitoring hold great potential for optimal diabetes management. This is often undermined by a variety of issues associated with: (1) negative tissue response; (2) poor sensor performance; and (3) lack of device miniaturization needed to reduce implantation trauma. Herein, we report our initial results towards constructing an implantable device that simultaneously address all three aforementioned issues. In terms of device miniaturization, a highly miniaturized CMOS (complementary metal-oxide-semiconductor) potentiostat and signal processing unit was employed (with a combined area of 0.665 mm(2)). The signal processing unit converts the current generated by a transcutaneous, Clark-type amperometric sensor to output frequency in a linear fashion. The Clark-type amperometric sensor employs stratification of five functional layers to attain a well-balanced mass transfer which in turn yields a linear sensor response from 0 to 25 mM of glucose concentration, well beyond the physiologically observed (2 to 22 mM) range. In addition, it is coated with a thick polyvinyl alcohol (PVA) hydrogel with embedded poly(lactic-co-glycolic acid) (PLGA) microspheres intended to provide continuous, localized delivery of dexamethasone to suppress inflammation and fibrosis. In vivo evaluation in rat model has shown that the transcutaneous sensor system reproducibly tracks repeated glycemic events. Clarke's error grid analysis on the as-obtained glycemic data has indicated that all of the measured glucose readings fell in the desired Zones A & B and none fell in the erroneous Zones C, D and E. Such reproducible operation of the transcutaneous sensor system, together with low power (140 μW) consumption and capability for current-to-frequency conversion renders this a versatile platform for continuous glucose monitoring and other biomedical sensing devices.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22992979      PMCID: PMC3545049          DOI: 10.1007/s10544-012-9708-x

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  44 in total

1.  Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

Authors:  C Choleau; J C Klein; G Reach; B Aussedat; V Demaria-Pesce; G S Wilson; R Gifford; W K Ward
Journal:  Biosens Bioelectron       Date:  2002-08       Impact factor: 10.618

Review 2.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Biocompatibility of an enzyme-based, electrochemical glucose sensor for short-term implantation in the subcutis.

Authors:  Peter Helding Kvist; Tine Iburg; Bent Aalbaek; Michael Gerstenberg; Christina Schoier; Peter Kaastrup; Thomas Buch-Rasmussen; Erik Hasselager; Henrik Elvang Jensen
Journal:  Diabetes Technol Ther       Date:  2006-10       Impact factor: 6.118

4.  Effect of physical ageing on the performance of dexamethasone loaded PLGA microspheres.

Authors:  Archana Rawat; Diane J Burgess
Journal:  Int J Pharm       Date:  2011-06-01       Impact factor: 5.875

5.  A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors.

Authors:  B D McKean; D A Gough
Journal:  IEEE Trans Biomed Eng       Date:  1988-07       Impact factor: 4.538

6.  A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors.

Authors:  M C Shults; R K Rhodes; S J Updike; B J Gilligan; W N Reining
Journal:  IEEE Trans Biomed Eng       Date:  1994-10       Impact factor: 4.538

7.  Dexamethasone-loaded poly(lactic-co-glycolic) acid microspheres/poly(vinyl alcohol) hydrogel composite coatings for inflammation control.

Authors:  Siddhesh D Patil; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  Diabetes Technol Ther       Date:  2004-12       Impact factor: 6.118

8.  Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

Authors:  Ram Weiss; Yevgeny Yegorchikov; Alexander Shusterman; Itamar Raz
Journal:  Diabetes Technol Ther       Date:  2007-02       Impact factor: 6.118

9.  Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis.

Authors:  Siddhesh D Patil; Fotios Papadmitrakopoulos; Diane J Burgess
Journal:  J Control Release       Date:  2006-10-19       Impact factor: 9.776

10.  Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode.

Authors:  Xia Chu; Daxue Duan; Guoli Shen; Ruqin Yu
Journal:  Talanta       Date:  2006-10-27       Impact factor: 6.057

View more
  6 in total

1.  Effects of a physical and energetic challenge on male California mice (Peromyscus californicus): modulation by reproductive condition.

Authors:  Meng Zhao; Theodore Garland; Mark A Chappell; Jacob R Andrew; Breanna N Harris; Wendy Saltzman
Journal:  J Exp Biol       Date:  2018-01-11       Impact factor: 3.312

2.  Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size.

Authors:  Yan Wang; Santhisagar Vaddiraju; Bing Gu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

Review 3.  Nanomaterial-mediated Biosensors for Monitoring Glucose.

Authors:  Masashige Taguchi; Andre Ptitsyn; Eric S McLamore; Jonathan C Claussen
Journal:  J Diabetes Sci Technol       Date:  2014-03-02

Review 4.  Microdialysis sampling techniques applied to studies of the foreign body reaction.

Authors:  Cynthia R Sides; Julie A Stenken
Journal:  Eur J Pharm Sci       Date:  2013-11-21       Impact factor: 4.384

5.  Enhancing the sensitivity of needle-implantable electrochemical glucose sensors via surface rebuilding.

Authors:  Santhisagar Vaddiraju; Allen Legassey; Liangliang Qiang; Yan Wang; Diane J Burgess; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

6.  Continuous metabolic monitoring based on multi-analyte biomarkers to predict exhaustion.

Authors:  Michail Kastellorizios; Diane J Burgess
Journal:  Sci Rep       Date:  2015-06-01       Impact factor: 4.379

  6 in total