Literature DB >> 17169457

Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis.

Siddhesh D Patil1, Fotios Papadmitrakopoulos, Diane J Burgess.   

Abstract

Localized elution of corticosteroids has been used in suppressing inflammation and fibrosis associated with implantation and continuous in vivo residence of bio-medical devices. However, these agents also inhibit endogenous growth factors preventing angiogenesis at the local tissue, interface thereby delaying the healing process and negatively impacting device performance. In this work, a combination of dexamethasone and vascular endothelial growth factor (VEGF) was investigated for concurrent localized delivery using PLGA microsphere/PVA hydrogel composites. Pharmacodynamic effects were evaluated by histopathological examination of subcutaneous tissue surrounding implanted composites using a rat model. The hydrogel composites were capable of simultaneously releasing VEGF and dexamethasone with approximately zero order kinetics. Composites were successful in controlling the implant/tissue interface by suppressing inflammation and fibrosis as well as facilitating neo-angiogenesis at a fraction of their typical oral or i.v. bolus doses. Implants containing VEGF showed a significantly higher number of mature blood vessels at the end of the 4 week study irrespective of the presence of dexamethasone. Thus, localized concurrent elution of VEGF and dexamethasone can overcome the anti-angiogenic effects of the corticosteroid and can be used to engineer inflammation-free and well-vascularized tissue in the vicinity of the implant. These PLGA microsphere/PVA hydrogel composites show promise as coatings for implantable bio-medical devices to improve biocompatibility and ensure in vivo performance.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17169457     DOI: 10.1016/j.jconrel.2006.10.013

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  65 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

2.  Glucose sensor membranes for mitigating the foreign body response.

Authors:  Ahyeon Koh; Scott P Nichols; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

3.  Controlled release of triamcinolone acetonide from polyurethane implantable devices: application for inhibition of inflammatory-angiogenesis.

Authors:  Flávia Carmo Horta Pinto; Armando Da Silva-Cunha Junior; Rodrigo Lambert Oréfice; Eliane Ayres; Silvia Passos Andrade; Luiza Dias C Lima; Sandra A Lima Moura; Gisele Rodrigues Da Silva
Journal:  J Mater Sci Mater Med       Date:  2012-04-01       Impact factor: 3.896

Review 4.  Angiogenic therapy for cardiac repair based on protein delivery systems.

Authors:  F R Formiga; E Tamayo; T Simón-Yarza; B Pelacho; F Prósper; M J Blanco-Prieto
Journal:  Heart Fail Rev       Date:  2012-05       Impact factor: 4.214

5.  The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants.

Authors:  Scott P Nichols; Ahyeon Koh; Nga L Brown; Michael B Rose; Bin Sun; Danielle L Slomberg; Daniel A Riccio; Bruce Klitzman; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2012-06-27       Impact factor: 12.479

Review 6.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

7.  Microsphere erosion in outer hydrogel membranes creating macroscopic porosity to counter biofouling-induced sensor degradation.

Authors:  S Vaddiraju; Y Wang; L Qiang; D J Burgess; F Papadimitrakopoulos
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

8.  Controlling fibrous capsule formation through long-term down-regulation of collagen type I (COL1A1) expression by nanofiber-mediated siRNA gene silencing.

Authors:  Pim-on Rujitanaroj; Brian Jao; Junghoon Yang; Feng Wang; James M Anderson; Jun Wang; Sing Yian Chew
Journal:  Acta Biomater       Date:  2012-10-02       Impact factor: 8.947

Review 9.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

10.  Polyelectrolyte-coated alginate microspheres as drug delivery carriers for dexamethasone release.

Authors:  R D Jayant; M J McShane; R Srivastava
Journal:  Drug Deliv       Date:  2009-08       Impact factor: 6.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.