Literature DB >> 2294343

Aortic valve replacement with stentless porcine aortic bioprosthesis.

T E David1, C Pollick, J Bos.   

Abstract

Twenty-nine patients were entered in a clinical trial on aortic valve replacement with a stentless glutaraldehyde-fixed porcine aortic valve. This bioprosthesis is secured to the aortic root by the same technique used for aortic valve replacement with aortic valve homografts. The functional results obtained from this operation have been most satisfactory. To assess the hemodynamic benefit of eliminating the stent of a porcine aortic valve, we matched 22 patients with a stentless porcine bioprosthesis for age, sex, body surface area, valve lesion, and bioprosthesis size to 22 patients who had aortic valve replacement with a Hancock II bioprosthesis. Mean and peak systolic gradients across the aortic bioprosthesis and effective aortic valve areas were obtained by Doppler studies. Gradients across the stentless bioprosthesis were significantly lower than gradients across the Hancock II valve for every bioprosthesis size. Effective aortic valve areas of the stentless bioprosthesis were significantly larger than the valve areas of the Hancock II valve. Our data demonstrate that the hemodynamic characteristics of a glutaraldehyde-fixed porcine aortic bioprosthesis are greatly improved when the aortic root is used as a stent for the valve. This technique of implantation is expected to enhance the durability of the bioprosthesis, because the aortic root may dampen the mechanical stress to which the leaflets are subjected during the cardiac cycle.

Entities:  

Mesh:

Year:  1990        PMID: 2294343

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

1.  Hemodynamic performance of the Edwards Prima Plus stentless valve at 1 year.

Authors:  Keizo Tanaka; Toshihiko Kinoshita; Kazuya Fujinaga; Shinji Kanemitsu; Jin Tanaka; Hitoshi Suzuki; Toshiya Tokui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-09-13

Review 2.  A look at recent improvements in the durability of tissue valves.

Authors:  Takahiro Nishida; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-01-24

3.  [Mechanical versus biological heart valves].

Authors:  J Ennker; A Lauruschkat
Journal:  Z Kardiol       Date:  2001-12

Review 4.  Tirone on Tirone David operation and types.

Authors:  Tirone E David
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-08-28

5.  Stentless bioprostheses have ideal haemodynamics, even in the small aortic root.

Authors:  L H Baur; Y Houdas; K H Peels; J Braun; B van Straten; A Prat; A P Kappetein; M Wolters-Geldoff; E E van der Wall; A V Bruschke; H A Huysmans
Journal:  Int J Card Imaging       Date:  2000-10

6.  The use of a stentless porcine bioprosthesis to repair an ascending aortic aneurysm in combination with aortic valve regurgitation.

Authors:  B Akpinar; I Sanisoğlu; C Konuralp; H Akay; M Güden; B Sönmez
Journal:  Tex Heart Inst J       Date:  1999

Review 7.  Surgical treatment of aortic valve disease.

Authors:  Tirone E David
Journal:  Nat Rev Cardiol       Date:  2013-05-14       Impact factor: 32.419

8.  Hospital Results of a Single Center Database for Stentless Xenograft Use in a Full Root Technique in Over 970 Patients.

Authors:  Jerry Easo; Alexander Weymann; Philipp Hölzl; Michael Horst; Harald Eichstaedt; Ahmed Mashhour; Konstantin Zhigalov; Marcin Szczechowicz; Rohit Philip Thomas; Anton Sabashnikov; Otto E Dapunt
Journal:  Sci Rep       Date:  2019-03-13       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.