Literature DB >> 22929831

"Add-on pacing lead": an effective and safe alternative to lead replacement in ICD pacing failure.

Sudeep Kumar1, Nagaraja Moorthy, Aditya Kapoor.   

Abstract

Despite recent advances in implantable cardioverter defibrillator (ICD) technology, the long-term reliability of ICD leads remains a significant problem. Lead failures constitute a major risk for patients with an implantable cardioverter defibrillator. There is no clear consensus on treatment strategy of ICD lead failure and decision should be individualized. We report a pacing-dependent elderly male with ICD lead pacing failure secondary to insulation break resulting in recurrent syncope. We emphasize the technique of "Add-on pacing lead implantation" could be an effective and alternative to ICD lead replacement.
Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22929831      PMCID: PMC3860817          DOI: 10.1016/j.ihj.2012.06.012

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  8 in total

1.  Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports.

Authors:  William H Maisel; Megan Moynahan; Bram D Zuckerman; Thomas P Gross; Oscar H Tovar; Donna-Bea Tillman; Daniel B Schultz
Journal:  JAMA       Date:  2006-04-26       Impact factor: 56.272

2.  Pacemaker and ICD generator reliability: meta-analysis of device registries.

Authors:  William H Maisel
Journal:  JAMA       Date:  2006-04-26       Impact factor: 56.272

3.  Sensing/pacing lead complications with a newer generation implantable cardioverter-defibrillator: worldwide experience from the Guardian ATP 4210 clinical trial.

Authors:  B S Stambler; M A Wood; R J Damiano; P S Greenway; M L Smutka; K A Ellenbogen
Journal:  J Am Coll Cardiol       Date:  1994-01       Impact factor: 24.094

4.  Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads.

Authors:  L M Epstein; C L Byrd; B L Wilkoff; C J Love; T D Sellers; D L Hayes; C Reiser
Journal:  Circulation       Date:  1999-08-03       Impact factor: 29.690

5.  Recalls and safety alerts involving pacemakers and implantable cardioverter-defibrillator generators.

Authors:  W H Maisel; M O Sweeney; W G Stevenson; K E Ellison; L M Epstein
Journal:  JAMA       Date:  2001-08-15       Impact factor: 56.272

6.  Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.

Authors:  Thomas Kleemann; Torsten Becker; Klaus Doenges; Margit Vater; Jochen Senges; Steffen Schneider; Werner Saggau; Udo Weisse; Karlheinz Seidl
Journal:  Circulation       Date:  2007-04-30       Impact factor: 29.690

7.  Detection and management of an implantable cardioverter defibrillator lead failure: incidence and clinical implications.

Authors:  Kenneth A Ellenbogen; Mark A Wood; Richard K Shepard; Henry F Clemo; Tim Vaughn; Keith Holloman; Marlene Dow; Jeanne Leffler; Athula Abeyratne; Dave Verness
Journal:  J Am Coll Cardiol       Date:  2003-01-01       Impact factor: 24.094

8.  Late complications in patients with pectoral defibrillator implants with transvenous defibrillator lead systems: high incidence of insulation breakdown.

Authors:  D Mehta; H M Nayak; M Singson; S Chao; E Pe; J L Camuñas; J A Gomes
Journal:  Pacing Clin Electrophysiol       Date:  1998-10       Impact factor: 1.976

  8 in total