CONTEXT: Unanticipated pacemaker and implantable cardioverter-defibrillator (ICD) generator malfunctions sometimes warrant recall by the US Food and Drug Administration (FDA). Despite increasingly frequent device implantation, pacemaker and ICD recalls and safety alerts (advisories) remain poorly characterized. OBJECTIVES: To determine pacemaker and ICD generator advisory rates in the United States, to identify trends in these rates, and to examine their clinical and financial implications. DESIGN AND SETTING: Analysis of weekly FDA Enforcement Reports issued between January 1990 and December 2000 to identify all advisories involving pacemaker or ICD generators in the United States. Recalls and safety alerts involving lead malfunctions were not included. MAIN OUTCOME MEASURES: Number of pacemakers and ICD generators in the United States subject to FDA recall or safety alert in 1990-2000; annual pacemaker and ICD advisory rates in the United States in 1990-2000; and estimated cost of device advisories. RESULTS: During the study period, 52 advisories (median [25th and 75th percentiles], 4 [4 and 7] per year) involving 408 500 pacemakers and 114 645 ICDs (523 145 total devices) were issued. Hardware malfunctions (35 advisories affecting 280 641 devices) and computer errors (10 advisories affecting 216 533 devices) accounted for 95% of device recalls. Implantable cardioverter-defibrillators were recalled more frequently than pacemakers (mean [SD], 16.4 [1.6] vs 6.7 [0.8] advisories per 100 person-years; P<.001). Between 1995 and 2000, the annual advisory rate increased for both pacemakers (P for trend <.001) and ICDs (P for trend =.02). An estimated 1.3 million device checks and analyses and 36 187 device replacements resulted from the advisories and cost approximately $870 million. CONCLUSIONS: Pacemaker and ICD recalls and safety alerts occur frequently, affect many patients, and appear to be increasing in number and rate. With the growing number of device implants and expanding indications for device therapy, the number of patients affected by device advisories will likely continue to increase.
CONTEXT: Unanticipated pacemaker and implantable cardioverter-defibrillator (ICD) generator malfunctions sometimes warrant recall by the US Food and Drug Administration (FDA). Despite increasingly frequent device implantation, pacemaker and ICDrecalls and safety alerts (advisories) remain poorly characterized. OBJECTIVES: To determine pacemaker and ICD generator advisory rates in the United States, to identify trends in these rates, and to examine their clinical and financial implications. DESIGN AND SETTING: Analysis of weekly FDA Enforcement Reports issued between January 1990 and December 2000 to identify all advisories involving pacemaker or ICD generators in the United States. Recalls and safety alerts involving lead malfunctions were not included. MAIN OUTCOME MEASURES: Number of pacemakers and ICD generators in the United States subject to FDA recall or safety alert in 1990-2000; annual pacemaker and ICD advisory rates in the United States in 1990-2000; and estimated cost of device advisories. RESULTS: During the study period, 52 advisories (median [25th and 75th percentiles], 4 [4 and 7] per year) involving 408 500 pacemakers and 114 645 ICDs (523 145 total devices) were issued. Hardware malfunctions (35 advisories affecting 280 641 devices) and computer errors (10 advisories affecting 216 533 devices) accounted for 95% of device recalls. Implantable cardioverter-defibrillators were recalled more frequently than pacemakers (mean [SD], 16.4 [1.6] vs 6.7 [0.8] advisories per 100 person-years; P<.001). Between 1995 and 2000, the annual advisory rate increased for both pacemakers (P for trend <.001) and ICDs (P for trend =.02). An estimated 1.3 million device checks and analyses and 36 187 device replacements resulted from the advisories and cost approximately $870 million. CONCLUSIONS: Pacemaker and ICDrecalls and safety alerts occur frequently, affect many patients, and appear to be increasing in number and rate. With the growing number of device implants and expanding indications for device therapy, the number of patients affected by device advisories will likely continue to increase.
Authors: M J W Götte; I K Rüssel; G J de Roest; T Germans; R F Veldkamp; P Knaapen; C P Allaart; A C van Rossum Journal: Neth Heart J Date: 2010-01 Impact factor: 2.380
Authors: Jay Sengupta; Arthur C Kendig; Marlene Goormastic; Eui-Seock Hwang; Elizabeth A Ching; Roy Chung; Bruce D Lindsay; Patrick J Tchou; Bruce L Wilkoff; Mark J Niebauer; David O Martin; Niraj Varma; Oussama Wazni; Walid Saliba; Mohamed Kanj; Mandeep Bhargava; Thomas Dresing; Tyler Taigen; Christopher Ingelmo; Mohamed Bassiouny; Edmond M Cronin; Bradley Wilsmore; John Rickard; Mina K Chung Journal: Heart Rhythm Date: 2012-07-03 Impact factor: 6.343
Authors: Andrew D Krahn; Christopher S Simpson; Ratika Parkash; Raymond Yee; Jean Champagne; Jeffrey S Healey; Doug Cameron; Bernard Thibault; Iqwal Mangat; Stanley Tung; Laurence Sterns; David H Birnie; Derek V Exner; Soori Sivakumaran; Ted Davies; Benoit Coutu; Eugene Crystal; Kevin Wolfe; Atul Verma; Elizabeth A Stephenson; Shubhayan Sanatani; Robert Gow; Sean Connors; Felix Ayala Paredes; Mike Turabian; Teresa Kus; Vidal Essebag; Martin Gardner Journal: Can J Cardiol Date: 2009-07 Impact factor: 5.223
Authors: George K Joseph; Bruce L Wilkoff; Thomas Dresing; John Burkhardt; Yaariv Khaykin Journal: J Interv Card Electrophysiol Date: 2004-10 Impact factor: 1.900