Survey of blood pump diaphragm damage in the NIPRO-ventricular assist device.

Koichi Kashiwa1, Takashi Nishimura, Aoi Nakahata, Naoki Momose, Chinori Umeda, Hitoshi Kubo, Hisayoshi Tamai, Koichiro Kinugawa, Hideo Adachi, Atsushi Yamaguchi, Tomoyuki Yambe, Toshiyuki Katohgi, Shunei Kyo, Minoru Ono.   

Abstract

We surveyed the incidence of blood pump diaphragm damage (rupture or crack) in the NIPRO-ventricular assist device (VAD). In the cases in which rupture or suspected blood pump crack was detected, we disassembled the pumps to visually check the condition of the diaphragm after replacement or use. Of 366 blood pumps surveyed, diaphragm damage was observed in 2.7 %. The duration of use of the blood pumps with diaphragm damage was significantly longer than that of pumps without damage. The incidence of diaphragm damage increased with longer duration of use. On the basis of these findings, blood pump diaphragm damage in the NIPRO-VAD may be associated with duration of use. However, some blood pumps were used for prolonged periods without diaphragm damage. All blood pumps with damage had a crack in the diaphragm on the air chamber side near the diaphragm-housing (D-H) junction. Cracks were not found in any specific part of the diaphragm. In blood pumps with diaphragm rupture, the crack had a through-hole reaching the blood-contacting surface. Although we were unable to identify the causes of the cracks, it is suggested that when a crack appears in the diaphragm it will gradually expand and eventually lead to rupture. If a crack is detected in a blood pump, we advocate replacing the pump before it grows. When the NIPRO-VAD is used, it is necessary to keep in mind that blood pump diaphragm damage may occur.

Entities:  

Mesh:

Year:  2012        PMID: 22923169     DOI: 10.1007/s10047-012-0657-1

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  9 in total

1.  Prolonged biventricular assist device support as a bridge to heart transplantation.

Authors:  Chitaru Kurihara; Minoru Ono; Takashi Nishimura; Kan Nawata; Osamu Kinoshita; Motoyuki Hisagi; Noboru Motomura; Shunei Kyo
Journal:  J Artif Organs       Date:  2011-07-23       Impact factor: 1.731

2.  Ventricular assist device as a bridge to heart transplantation in adults.

Authors:  C Engin; F Ayik; E Oguz; B Eygi; T Yagdi; S Karakula; M Ozbaran
Journal:  Transplant Proc       Date:  2011-04       Impact factor: 1.066

3.  High-dose carvedilol therapy for mechanical circulatory assisted patients.

Authors:  Takashi Nishimura; Shunei Kyo
Journal:  J Artif Organs       Date:  2010-04-03       Impact factor: 1.731

4.  Clinical experience with ventricular assist systems in Japan.

Authors:  H Takano; T Nakatani; Y Taenaka
Journal:  Ann Thorac Surg       Date:  1993-01       Impact factor: 4.330

5.  [Cardiomyopathy and myocarditis; surgical treatment including ventricular assist device and heart transplantation].

Authors:  Minoru Ono
Journal:  Kyobu Geka       Date:  2011-07

6.  Use of the AB5000 ventricular assist device in cardiogenic shock after acute myocardial infarction.

Authors:  Mark Anderson; Nicholas Smedira; Louis Samuels; Michael Madani; Yoshifumi Naka; Michael Acker; Mariah Hout; Karim Benali
Journal:  Ann Thorac Surg       Date:  2010-09       Impact factor: 4.330

7.  Successful bridge to recovery with VAD implantation for anthracycline-induced cardiomyopathy.

Authors:  Chitaru Kurihara; Takashi Nishimura; Kan Nawata; Osamu Kinoshita; Motoyuki Hisagi; Noboru Motomura; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2011-05-03       Impact factor: 1.731

8.  Initial experience with the Abiomed AB5000 ventricular assist device system.

Authors:  Louis E Samuels; Elena C Holmes; Phil Garwood; Francis Ferdinand
Journal:  Ann Thorac Surg       Date:  2005-07       Impact factor: 4.330

9.  Multi-institutional studies of the National Cardiovascular Center Ventricular Assist System: use in 92 patients.

Authors:  H Takano; Y Taenaka; H Noda; M Kinoshita; A Yagura; E Tatsumi; H Sekii; E Sasaki; M Umezu; T Nakatani
Journal:  ASAIO Trans       Date:  1989 Jul-Sep
  9 in total
  1 in total

Review 1.  Current status of extracorporeal ventricular assist devices in Japan.

Authors:  Takashi Nishimura
Journal:  J Artif Organs       Date:  2014-06-22       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.