Literature DB >> 21786072

Prolonged biventricular assist device support as a bridge to heart transplantation.

Chitaru Kurihara1, Minoru Ono, Takashi Nishimura, Kan Nawata, Osamu Kinoshita, Motoyuki Hisagi, Noboru Motomura, Shunei Kyo.   

Abstract

We report a case in which long-term biventricular assist device (BiVAD) support enabled successful heart transplantation. The patient was diagnosed with dilated cardiomyopathy at age 11. She underwent implantation of a Toyobo LVAD, tricuspid valvuloplasty and annuloplasty at age 15. Right heart bypass (RHB) was established using a centrifugal pump. Right ventricular function showed no improvement during a ten-day period, and RHB was switched to a Toyobo RVAD on postoperative day (POD) 11. Because of poor oxygenation, veno-venous extracorporeal membrane oxygenation (V-V ECMO) was instituted. She was weaned from V-V ECMO on POD 14. She was brought to the United States on POD 189 under BiVAD support, and underwent heart transplantation on POD 199. She was discharged 4 months later. Two years after heart transplantation, she remained in New York Heart Association class one without rejection.

Entities:  

Mesh:

Year:  2011        PMID: 21786072     DOI: 10.1007/s10047-011-0593-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  13 in total

1.  Mechanical Circulatory Support Device Database of the International Society for Heart and Lung Transplantation: second annual report--2004.

Authors:  Mario C Deng; Leah B Edwards; Marshall I Hertz; Amanda W Rowe; Berkeley M Keck; Robert Kormos; David C Naftel; James K Kirklin
Journal:  J Heart Lung Transplant       Date:  2004-09       Impact factor: 10.247

2.  Right-to-left ventricular end-diastolic diameter ratio and prediction of right ventricular failure with continuous-flow left ventricular assist devices.

Authors:  Marian Kukucka; Alexander Stepanenko; Evgenij Potapov; Thomas Krabatsch; Mathias Redlin; Alexander Mladenow; Hermann Kuppe; Roland Hetzer; Helmut Habazettl
Journal:  J Heart Lung Transplant       Date:  2010-10-29       Impact factor: 10.247

3.  Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure.

Authors:  Nicholas C Dang; Veli K Topkara; Michelle Mercando; Joy Kay; Kurt H Kruger; Michael S Aboodi; Mehmet C Oz; Yoshifumi Naka
Journal:  J Heart Lung Transplant       Date:  2005-12-09       Impact factor: 10.247

4.  Biventricular assist device-induced right ventricular reverse structural and functional remodeling.

Authors:  Stefan Klotz; Yoshifumni Naka; Mehmet C Oz; Daniel Burkhoff
Journal:  J Heart Lung Transplant       Date:  2005-09       Impact factor: 10.247

5.  Influence of left ventricular assist on valvular regurgitation.

Authors:  W L Holman; R C Bourge; P Fan; J K Kirklin; A D Pacifico; N C Nanda
Journal:  Circulation       Date:  1993-11       Impact factor: 29.690

6.  Effects of failure of the right side of the heart and increased pulmonary resistance on mechanical circulatory support with use of the miniaturized HIA-VAD displacement pump system.

Authors:  F Waldenberger; Y I Kim; S Laycock; B Meyns; W Flameng
Journal:  J Thorac Cardiovasc Surg       Date:  1996-08       Impact factor: 5.209

7.  Risk factor analysis of long-term support with left ventricular assist system.

Authors:  Shunsuke Saito; Goro Matsumiya; Taichi Sakaguchi; Shigeru Miyagawa; Yasushi Yoshikawa; Takashi Yamauchi; Toru Kuratani; Yoshiki Sawa
Journal:  Circ J       Date:  2010-02-17       Impact factor: 2.993

8.  Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support.

Authors:  J Raymond Fitzpatrick; John R Frederick; Vivian M Hsu; Elliott D Kozin; Mary Lou O'Hara; Elan Howell; Deborah Dougherty; Ryan C McCormick; Carine A Laporte; Jeffrey E Cohen; Kevin W Southerland; Jessica L Howard; Mariell L Jessup; Rohinton J Morris; Michael A Acker; Y Joseph Woo
Journal:  J Heart Lung Transplant       Date:  2008-12       Impact factor: 10.247

9.  Preoperative risk factors for mortality after biventricular assist device implantation.

Authors:  Firas Zahr; Yoshio Ootaki; Randall C Starling; Nicholas G Smedira; Mohamad Yamani; Lucy Thuita; Kiyotaka Fukamachi
Journal:  J Card Fail       Date:  2008-10-14       Impact factor: 5.712

10.  Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device.

Authors:  J Raymond Fitzpatrick; John R Frederick; William Hiesinger; Vivian M Hsu; Ryan C McCormick; Elliott D Kozin; Carine M Laporte; Mary Lou O'Hara; Elan Howell; Deborah Dougherty; Jeffrey E Cohen; Kevin W Southerland; Jessica L Howard; E Carter Paulson; Michael A Acker; Rohinton J Morris; Y Joseph Woo
Journal:  J Thorac Cardiovasc Surg       Date:  2009-04       Impact factor: 5.209

View more
  4 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

2.  Seventeen-month-long paracorporeal biventricular mechanical support as a bridge to transplantation for severe dilated cardiomyopathy.

Authors:  Tadashi Kitamura; Shinzo Torii; Norihiko Oka; Tetsuya Horai; Keiichi Itatani; Takeshi Yoshii; Yuki Nakamura; Miyuki Shibata; Tomoki Tamura; Haruna Araki; Yoshikiyo Matsunaga; Kagami Miyaji
Journal:  J Artif Organs       Date:  2014-10-16       Impact factor: 1.731

3.  Survey of blood pump diaphragm damage in the NIPRO-ventricular assist device.

Authors:  Koichi Kashiwa; Takashi Nishimura; Aoi Nakahata; Naoki Momose; Chinori Umeda; Hitoshi Kubo; Hisayoshi Tamai; Koichiro Kinugawa; Hideo Adachi; Atsushi Yamaguchi; Tomoyuki Yambe; Toshiyuki Katohgi; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2012-08-25       Impact factor: 1.731

4.  Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD.

Authors:  Wei-Che Chiu; Gaurav Girdhar; Michalis Xenos; Yared Alemu; Jõao S Soares; Shmuel Einav; Marvin Slepian; Danny Bluestein
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.