Literature DB >> 21486630

Ventricular assist device as a bridge to heart transplantation in adults.

C Engin1, F Ayik, E Oguz, B Eygi, T Yagdi, S Karakula, M Ozbaran.   

Abstract

BACKGROUND: Because of the shortage of donor hearts, various ventricular asist devices (VAD) have been used in decompensated patients to prolong patient survival until a suitable heart becomes available. In this paper, we present our single-center report of adult patients in whom bridging was used with VAD.
METHODS: We performed a retrospective review of 14 adult patients who underwent heart transplantation after insertion of a long-term VAD. The study spans from February 2006 until September 2010. The mean patient age was 44.28 ± 11.06 years. We used the Berlin Heart EXCOR VADs (n = 11; Berlin Heart AG Berlin, Germany), or the Berlin Heart Incor (n = 2), or the Abiomed AB500 (n = 1). Preimplantation status of the subjects were critical cardiogenic shock (n = 6), deterioration on inotropes (n = 3), or stable but inotrope-dependent (n = 5).
RESULTS: Mean VAD support time was 153.71 days (range, 25-517). Major adverse events during VAD support included reexploration for bleeding (n = 3; 21.4%), neurologic events (n = 2; 14.3%), left VAD-related infection (n = 2; 14.3%), pneumonia (n = 1; 14.3%), or primary device failure (n = 1; 7.1%). One (7.1%) patient showed evidence of human leukocyte antigen sensitization. There were 2 deaths (14.3%) over a mean of 324 days follow-up after heart transplantation: One due to biventricular failure in the early postoperative period and the other, at 69 days from pneumonia. Rejection was observed in 2 patients who had International Society for Heart and Lung Transplantation grade 2R without hemodynamic deterioration. In our series, the 1-year mortality was 14.4% among heart transplantations without VAD implantation and 14.2% among the bridge-to-transplantation group.
CONCLUSION: We conclude that VAD implantation improved end-organ function before heart transplantation in critically ill patients.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21486630     DOI: 10.1016/j.transproceed.2011.01.147

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  1 in total

1.  Survey of blood pump diaphragm damage in the NIPRO-ventricular assist device.

Authors:  Koichi Kashiwa; Takashi Nishimura; Aoi Nakahata; Naoki Momose; Chinori Umeda; Hitoshi Kubo; Hisayoshi Tamai; Koichiro Kinugawa; Hideo Adachi; Atsushi Yamaguchi; Tomoyuki Yambe; Toshiyuki Katohgi; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2012-08-25       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.