Comparison between an accelerometer and a three-dimensional motion analysis system for the detection of movement.

P Y M Chung1, G Y F Ng.   

Abstract

OBJECTIVE: To examine the reliability and concurrent validity of an accelerometer compared with a three-dimensional (3D) motion analysis system for measuring the motor reaction time of the lower limbs, to validate a simple method for objective clinical assessment of movement onset.
DESIGN: Timing of the onset of knee extension movement in response to an audio signal was measured simultaneously with an accelerometer and a 3D VICON motion analysis system. PARTICIPANTS: Twelve able-bodied subjects with a mean age of 26 (standard deviation 2.3) years.
RESULTS: Good reliability was found for both instruments, although the intraclass correlation coefficient (ICC) was higher for the accelerometer (ICC₃,₁=0.739; P<0.001). The mean motor reaction time measured by the accelerometer and the VICON system was 205.0 and 196.9 mseconds, respectively. Good agreement was found between the paired measurements (mean ICC=0.774), and the average 95% limits of agreement were -56.4 to 72.5 mseconds.
CONCLUSION: In conclusion, the accelerometer had good reliability for the measurement of movement onset time. Agreement between the measurements from the accelerometer and the VICON system was high. However, the limits of agreement covered a wide range, so absolute timings for movement onset derived from these methods should not be used interchangeably.
Copyright © 2011. Published by Elsevier Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 22898584     DOI: 10.1016/j.physio.2011.06.003

Source DB:  PubMed          Journal:  Physiotherapy        ISSN: 0031-9406            Impact factor:   3.358


  9 in total

1.  Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

Authors:  David A Krause; Michael S Boyd; Allison N Hager; Eric C Smoyer; Anthony T Thompson; John H Hollman
Journal:  Int J Sports Phys Ther       Date:  2015-02

Review 2.  A review of computational approaches for evaluation of rehabilitation exercises.

Authors:  Yalin Liao; Aleksandar Vakanski; Min Xian; David Paul; Russell Baker
Journal:  Comput Biol Med       Date:  2020-03-04       Impact factor: 4.589

3.  Validation of a Wearable Sensor for Measuring Running Biomechanics.

Authors:  Rachel M Koldenhoven; Jay Hertel
Journal:  Digit Biomark       Date:  2018-08-02

4.  Automatic determination of validity of input data used in ellipsoid fitting MARG calibration algorithms.

Authors:  Alberto Olivares; Gonzalo Ruiz-Garcia; Gonzalo Olivares; Juan Manuel Górriz; Javier Ramirez
Journal:  Sensors (Basel)       Date:  2013-09-05       Impact factor: 3.576

5.  Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study.

Authors:  Jan Lodin; Marek Jelínek; Martin Sameš; Petr Vachata
Journal:  Sensors (Basel)       Date:  2022-02-19       Impact factor: 3.576

6.  Cervical coupling motion characteristics in healthy people using a wireless inertial measurement unit.

Authors:  Hyunho Kim; Sang-Hoon Shin; Jeong-Kyun Kim; Young-Jae Park; Hwan-Sup Oh; Young-Bae Park
Journal:  Evid Based Complement Alternat Med       Date:  2013-07-09       Impact factor: 2.629

7.  Analysis of asymmetry of the forces applied on the lower limb in subjects with nonspecific chronic low back pain.

Authors:  Maryam Hassan Zahraee; Mohammad Taghi Karimi; Javid Mostamand; Francis Fatoye
Journal:  Biomed Res Int       Date:  2014-07-01       Impact factor: 3.411

8.  Comparison between a center of mass and a foot pressure sensor system for measuring gait parameters in healthy adults.

Authors:  Gunoh Park; Youngkeun Woo
Journal:  J Phys Ther Sci       Date:  2015-10-30

9.  Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

Authors:  Russell R Russo; Matthew B Burn; Sabir K Ismaily; Brayden J Gerrie; Shuyang Han; Jerry Alexander; Christopher Lenherr; Philip C Noble; Joshua D Harris; Patrick C McCulloch
Journal:  J Exp Orthop       Date:  2017-09-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.