Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

David A Krause1, Michael S Boyd2, Allison N Hager2, Eric C Smoyer2, Anthony T Thompson2, John H Hollman1.   

Abstract

BACKGROUND/
PURPOSE: The squat is a fundamental movement of many athletic and daily activities. Methods to clinically assess the squat maneuver range from simple observation to the use of sophisticated equipment. The purpose of this study was to examine the reliability of Coach's Eye (TechSmith Corp), a 2-dimensional (2D) motion analysis mobile device application (app), for assessing maximal sagittal plane hip, knee, and ankle motion during a functional movement screen deep squat, and to compare range of motion values generated by it to those from a Vicon (Vicon Motion Systems Ltd) 3-dimensional (3D) motion analysis system.
METHODS: Twenty-six healthy subjects performed three functional movement screen deep squats recorded simultaneously by both the app (on an iPad [Apple Inc]) and the 3D motion analysis system. Joint angle data were calculated with Vicon Nexus software (Vicon Motion Systems Ltd). The app video was analyzed frame by frame to determine, and freeze on the screen, the deepest position of the squat. With a capacitive stylus reference lines were then drawn on the iPad screen to determine joint angles. Procedures were repeated with approximately 48 hours between sessions.
RESULTS: Test-retest intrarater reliability (ICC3,1) for the app at the hip, knee, and ankle was 0.98, 0.98, and 0.79, respectively. Minimum detectable change was hip 6°, knee 6°, and ankle 7°. Hip joint angles measured with the 2D app exceeded measurements obtained with the 3D motion analysis system by approximately 40°. Differences at the knee and ankle were of lower magnitude, with mean differences of 5° and 3°, respectively. Bland-Altman analysis demonstrated a systematic bias in the hip range-of-motion measurement. No such bias was demonstrated at the knee or ankle.
CONCLUSIONS: The 2D app demonstrated excellent reliability and appeared to be a responsive means to assess for clinical change, with minimum detectable change values ranging from 6° to 7°. These results also suggest that the 2D app may be used as an alternative to a sophisticated 3D motion analysis system for assessing sagittal plane knee and ankle motion; however, it does not appear to be a comparable alternative for assessing hip motion. LEVEL OF EVIDENCE: 3.

Entities:  

Keywords:  Functional movement; range of motion; reliability; squat

Year:  2015        PMID: 25709861      PMCID: PMC4325286     

Source DB:  PubMed          Journal:  Int J Sports Phys Ther        ISSN: 2159-2896


  25 in total

1.  Comparison of 2-dimensional and 3-dimensional rearfoot motion during walking.

Authors:  M W Cornwall; T G McPoil
Journal:  Clin Biomech (Bristol, Avon)       Date:  1995-01       Impact factor: 2.063

2.  Reliability of a new application for smartphones (DrGoniometer) for elbow angle measurement.

Authors:  Giorgio Ferriero; Francesco Sartorio; Calogero Foti; Diego Primavera; Elisa Brigatti; Stefano Vercelli
Journal:  PM R       Date:  2011-12       Impact factor: 2.298

3.  Measurement of hip range of flexion-extension and straight-leg raising.

Authors:  R A Elson; G R Aspinall
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

4.  Pre-participation screening: the use of fundamental movements as an assessment of function - part 1.

Authors:  Gray Cook; Lee Burton; Barb Hoogenboom
Journal:  N Am J Sports Phys Ther       Date:  2006-05

5.  Concurrent validity and reliability of two-dimensional video analysis of hip and knee joint motion during mechanical lifting.

Authors:  Beth S Norris; Sharon L Olson
Journal:  Physiother Theory Pract       Date:  2011-05-15       Impact factor: 2.279

6.  Validation of a photography-based goniometry method for measuring joint range of motion.

Authors:  Davide Blonna; Peter C Zarkadas; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  J Shoulder Elbow Surg       Date:  2011-10-08       Impact factor: 3.019

7.  Effect of limiting ankle-dorsiflexion range of motion on lower extremity kinematics and muscle-activation patterns during a squat.

Authors:  Elisabeth Macrum; David Robert Bell; Michelle Boling; Michael Lewek; Darin Padua
Journal:  J Sport Rehabil       Date:  2011-11-15       Impact factor: 1.931

Review 8.  Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics.

Authors:  Ugo Della Croce; Alberto Leardini; Lorenzo Chiari; Aurelio Cappozzo
Journal:  Gait Posture       Date:  2005-02       Impact factor: 2.840

9.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

10.  Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty.

Authors:  Anton F Lenssen; Ellen M van Dam; Yvonne H F Crijns; Mark Verhey; Ruud J T Geesink; Piet A van den Brandt; Rob A de Bie
Journal:  BMC Musculoskelet Disord       Date:  2007-08-17       Impact factor: 2.362

View more
  8 in total

1.  The Concurrent Validity and Reliability of Single Leg Squat Among Physically Active Females with and without Dynamic Knee Valgus.

Authors:  Nazatul Izzati Jamaludin; Farhah Nadhirah Aiman Sahabuddin; Nur Syahmina Rasudin; Shazlin Shaharudin
Journal:  Int J Sports Phys Ther       Date:  2022-06-02

2.  A NOVEL TEST TO ASSESS CHANGE OF DIRECTION: DEVELOPMENT, RELIABILITY, AND REHABILITATION CONSIDERATIONS.

Authors:  Haley Worst; Nancy Henderson; Ryan Decarreau; George Davies
Journal:  Int J Sports Phys Ther       Date:  2019-04

3.  QUANTIFYING FRONTAL PLANE KNEE KINEMATICS IN SUBJECTS WITH ANTERIOR KNEE PAIN: THE RELIABILITY AND CONCURRENT VALIDITY OF 2D MOTION ANALYSIS.

Authors:  Michelle Ramirez; Rodney Negrete; William J Hanney; Morey J Kolber
Journal:  Int J Sports Phys Ther       Date:  2018-02

4.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity.

Authors:  Mohammad Al-Amri; Kevin Nicholas; Kate Button; Valerie Sparkes; Liba Sheeran; Jennifer L Davies
Journal:  Sensors (Basel)       Date:  2018-02-28       Impact factor: 3.576

5.  One session of motor control exercise improves joint position sense assessed by an iPhone application: a randomized controlled trial.

Authors:  Peemongkon Wattananon; Wanalee Klomjai; Won Sung
Journal:  J Phys Ther Sci       Date:  2019-07-09

6.  Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

Authors:  Russell R Russo; Matthew B Burn; Sabir K Ismaily; Brayden J Gerrie; Shuyang Han; Jerry Alexander; Christopher Lenherr; Philip C Noble; Joshua D Harris; Patrick C McCulloch
Journal:  J Exp Orthop       Date:  2017-09-07

7.  Validity and Reliability of the WIMUTM Inertial Device for the Assessment of Joint Angulations.

Authors:  Javier García-Rubio; José Pino; Pedro R Olivares; Sergio J Ibáñez
Journal:  Int J Environ Res Public Health       Date:  2019-12-27       Impact factor: 3.390

8.  Functional movement screen dataset collected with two Azure Kinect depth sensors.

Authors:  Qing-Jun Xing; Yuan-Yuan Shen; Run Cao; Shou-Xin Zong; Shu-Xiang Zhao; Yan-Fei Shen
Journal:  Sci Data       Date:  2022-03-25       Impact factor: 6.444

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.