Literature DB >> 22863905

Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants.

T J Webster1, A A Patel, M N Rahaman, B Sonny Bal.   

Abstract

Silicon nitride (Si(3)N(4)) is an industrial ceramic used in spinal fusion and maxillofacial reconstruction. Maximizing bone formation and minimizing bacterial infection are desirable attributes in orthopedic implants designed to adhere to living bone. This study has compared these attributes of Si(3)N(4) implants with implants made from two other orthopedic biomaterials, i.e. poly(ether ether ketone) (PEEK) and titanium (Ti). Dense implants made of Si(3)N(4), PEEK, or Ti were surgically implanted into matching rat calvarial defects. Bacterial infection was induced with an injection of 1×10(4)Staphylococcus epidermidis. Control animals received saline only. On 3, 7, and 14days, and 3months post-surgery four rats per time period and material were killed, and calvariae were examined to quantify new bone formation and the presence or absence of bacteria. Quantitative evaluation of osteointegration to adjacent bone was done by measuring the resistance to implant push-out (n=8 rats each for Ti and PEEK, and n=16 rats for Si(3)N(4)). Three months after surgery in the absence of bacterial injection new bone formation around Si(3)N(4) was ∼69%, compared with 24% and 36% for PEEK and Ti, respectively. In the presence of bacteria new bone formation for Si(3)N(4), Ti, and PEEK was 41%, 26%, and 21%, respectively. Live bacteria were identified around PEEK (88%) and Ti (21%) implants, whereas none were present adjacent to Si(3)N(4). Push-out strength testing demonstrated statistically superior bone growth onto Si(3)N(4) compared with Ti and PEEK. Si(3)N(4) bioceramic implants demonstrated superior new bone formation and resistance to bacterial infection compared with Ti and PEEK.
Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22863905     DOI: 10.1016/j.actbio.2012.07.038

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  43 in total

Review 1.  3-dimensional printing for anterior cervical surgery: a review.

Authors:  Wen Jie Choy; William C H Parr; Kevin Phan; William R Walsh; Ralph J Mobbs
Journal:  J Spine Surg       Date:  2018-12

2.  Arthroscopic double-row repair of the rotator cuff: a comparison of bio-absorbable and non-resorbable anchors regarding osseous reaction.

Authors:  Hendrik Haneveld; Konstantin Hug; Gerd Diederichs; Markus Scheibel; Christian Gerhardt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-21       Impact factor: 4.342

Review 3.  New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.

Authors:  Preston W Grieco; Scott Pascal; Jared M Newman; Neil V Shah; Sarah G Stroud; Neil P Sheth; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-27

4.  Bone Morphogenetic Protein 2-Conjugated Silica Particles Enhanced Early Osteogenic Differentiation of Adipose Stem Cells on the Polycaprolactone Scaffold.

Authors:  Ki Joo Kim; Moon Seop Choi; Jin Hyung Shim; Jong-Won Rhie
Journal:  Tissue Eng Regen Med       Date:  2019-06-18       Impact factor: 4.169

5.  Local and Systemic Changes Associated with Long-term, Percutaneous, Static Implantation of Titanium Alloys in Rhesus Macaques (Macaca mulatta).

Authors:  Galit H Frydman; Robert P Marini; Vasudevan Bakthavatchalu; Kathleen E Biddle; Sureshkumar Muthupalani; Charles R Vanderburg; Barry Lai; Pavan K Bendapudi; Ronald G Tompkins; James G Fox
Journal:  Comp Med       Date:  2017-03-01       Impact factor: 0.982

6.  Porous silicon nitride spacers versus PEEK cages for anterior cervical discectomy and fusion: clinical and radiological results of a single-blinded randomized controlled trial.

Authors:  Mark P Arts; Jasper F C Wolfs; Terry P Corbin
Journal:  Eur Spine J       Date:  2017-04-05       Impact factor: 3.134

7.  Bacteria antibiotic resistance: New challenges and opportunities for implant-associated orthopedic infections.

Authors:  Bingyun Li; Thomas J Webster
Journal:  J Orthop Res       Date:  2017-08-11       Impact factor: 3.494

8.  Surface topography of silicon nitride affects antimicrobial and osseointegrative properties of tibial implants in a murine model.

Authors:  Masahiro Ishikawa; Karen L de Mesy Bentley; Bryan J McEntire; B Sonny Bal; Edward M Schwarz; Chao Xie
Journal:  J Biomed Mater Res A       Date:  2017-09-26       Impact factor: 4.396

9.  Clinical outcomes for lumbar fusion using silicon nitride versus other biomaterials.

Authors:  Graham C Calvert; George VanBuren Huffmon; William M Rambo; Micah W Smith; Bryan J McEntire; B Sonny Bal
Journal:  J Spine Surg       Date:  2020-03

10.  Clinical outcomes for anterior cervical discectomy and fusion with silicon nitride spine cages: a multicenter study.

Authors:  Graham C Calvert; George VanBuren Huffmon; William M Rambo; Micah W Smith; Bryan J McEntire; B Sonny Bal
Journal:  J Spine Surg       Date:  2019-12